The American Dynamics ADACSNETD SensorNet/Manchester Distribution Panel
enables amplification of either SensorNet or Manchester protocol
signals for controlling multi-point dome cameras. This implies that the
user can control either protocol setting efficiently. In addition, the
device also allows effortless switching between the two protocols.
Home-run
dome wiring is accommodated by the Distribution Panel through its 16
output driver links - two connectors for each link. In order to
accommodate systems of varied sizes, the panel also supports multiple
daisy-chained links to the domes as well as J-Box wiring topologies.
You
can install the Distribution Panel at the head-end as well as at any
remote location. If there is power availability for the domes, the
device can be used in place of a SensorNet J-Box. The Panel has a
sleek, 2U rack-mount design. With the single PCB design, the device can
be mounted at the front or rear of an electronics rack, facing either
inside or outside.
The Distribution Panel is compatible with
MegaPower matrix switcher/controller systems and Intellex Digital Video
Management Systems. The panel is also compatible with varied types of
SpeedDome programmable dome cameras, J-Boxes, Manchester receiver
drivers, and control systems which use Manchester or SensorNet
protocols. The panel boasts inputs for two hosts. While the first one
lets you maintain connection between primary and back up CPUs, the
second one is meant for the other devices. Effectively this creates a
redundant solution.
-
Amplifies SensorNet or Manchester protocol signals for multi-point dome control
-
Switches easily between SensorNet or Manchester protocols
-
Accommodates home-run dome wiring via 16 output ports
-
Supports home-run, daisy chain, and junction box (J-Box) wiring topologies to accommodate any size system
-
Can be installed at head end or remote locations
-
Rack (2U) mountable
-
Thin, single PCB design allows the panel to be mounted either at the
front or rear of an electronics rack, facing in or out
-
Surge suppression available on all data and power connections
-
ADACSNETDP model includes power supply for multiple panels
-
Compatible with MegaPower matrix switcher/controller systems and Intellex Digital Video Management Systems
- USB Specifications
- Bit Rate . . . . . . . . . . . . . . . . . . . . . . .1.5 Mb/s Low Speed, 12 Mb/s Full Speed
- Maximum Cable Length . . . . . . . .3 m (9.8 ft) for 1.5 Mb/s, 5 m (16.4 ft) for 12 Mb/s
- Specification . . . . . . . . . . . . . . . . . . .Universal Serial Bus USB Specification Revision 1.1
- Connector . . . . . . . . . . . . . . . . . . . . .USB Type B receptacle
- Power Source . . . . . . . . . . . . . . . . . .5.0 VDC +/- 5%, 0.75 W from USB host controller port (power adapter not required)
- SensorNet Specifications
- Address Range . . . . . . . . . . . . . . . . .1 to 254 (configurable)
- Bit Rate . . . . . . . . . . . . . . . . . . . . . . .230.4 Kbps
- Network Distance . . . . . . . . . . . . . .1 km per node
- Maximum Loads . . . . . . . . . . . . . . .32 per node
- Node Repeaters . . . . . . . . . . . . . . . .SensorNet junction boxes
- Topologies Supported . . . . . . . . . .Daisy chain, Backbone, or Star
- Transmission Medium . . . . . . . . . .Single non-polarized unshielded twisted pair UTP 22 AWG
- Connector . . . . . . . . . . . . . . . . . . . . .Euro-style 2 pin removable plug 3.5 mm terminal block
- Terminating Resistor . . . . . . . . . . .120 ohms, switch selectable
- Physical Layer . . . . . . . . . . . . . . . . . .RS-485, transformer isolated, 2-wire
- Data Encoding . . . . . . . . . . . . . . . . .FM-0
- Link Layer Framing . . . . . . . . . . . . .SDLC/HDLC
- Link Layer Channel . . . . . . . . . . . . .Bi-directional, half duplex
- Collision Avoidance . . . . . . . . . . . .Polling by USB Module
- Application Protocol . . . . . . . . . . .Proprietary
- Network Nodes . . . . . . . . . . . . . . . .Domes, junction boxes, secondary TouchTracker, and SensorNet I/O unit
- Surge Protection
- SensorNet Gas discharge tube impulse rated at:
- DC breakdown voltage . . . . . . . .90 V
- Insulation resistance . . . . . . . . . .10,000 Mega ohms
- Capacitance . . . . . . . . . . . . . . . . . .2 pF max. 8/20 μs impulse
- discharge current . . . . . . . . . . . . .10 kA Ten 8/20μs impulses
- discharge current . . . . . . . . . . . . .5 kA
- Isolation transformer coupled . . .2000 Vrms
- PTC re-settable fuse protects transformer Transient voltage suppressors (TVS)
- Break down voltage . . . . . . . . . . .7.6�9.3 V
- Peak current . . . . . . . . . . . . . . . . . .40 A
- Capacitance . . . . . . . . . . . . . . . . . .2000 pf @ 1kHz
- USB: ESD suppressors protect USB lines by suppressing fast rising transients as specified in IEC 61000-4-2 and MIL-STD-883C (8k V discharge method)
- Environmental
- Temperature
- Operating . . . . . . . . . . . . . . . . . . . .10� to 50�C (14� to 122�F)
- Relative Humidity . . . . . . . . . . . .0 to 95% non-condensing
- Mechanical
- Length . . . . . . . . . . . . . . . . . . . . . . . .10.2 cm (4.0 in)
- Width . . . . . . . . . . . . . . . . . . . . . . . . .7.0 cm (2.8 in)
- Thickness . . . . . . . . . . . . . . . . . . . . .2.5 cm (1.0 in)
- Weight . . . . . . . . . . . . . . . . . . . . . . . . 0.5 kg (1.1 lbs)
- Regulatory Compliance
- EMC . . . . . . . . . . . . . . . . . . . . . . . . . .47 CFR, Part 15
- ICES-003
- EN55022
- CISPR 22
- Safety . . . . . . . . . . . . . . . . . . . . . . . . .UL 1950
- CSA C22.2 No 950
- TUV Rhienland EN60950
- IEC 950
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- Control a SpeedDome Optima, Optima LT or Ultra using a PC with all of the features of a TouchTracker – including DirectSet
- Monitor SensorNet communication links for testing and troubleshooting purposes
- Upgrade domes to the latest firmware via SensorNet without physical access to the dome
- Can be used in exiting SensorNet installations – anywhere a SensorNet connection is available
|
|
 |
 |
 |
 |
|
 |

|