APC Smart-UPS RT, 3500 Watts / 5000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot, Extended runtime model, Rack Height 3 U Includes: CD with software, Rack Mounting support rails, Smart UPS signalling RS-232 cable, User Manual, Web/SNMP Management Card
Output Output Power Capacity 3500 Watts / 5000 VA Max Configurable Power 3500 Watts / 5000 VA Nominal Output Voltage 230V Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage Efficiency at Full Load 92.00% Output Voltage Distortion Less than 3% Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Output Connections | (8) IEC 320 C13 | | | (2) IEC 320 C19 | | | (6) IEC Jumpers | | Bypass Internal Bypass (Automatic and Manual) Nominal Input Voltage 230V Input Frequency 50/60 Hz +/- 5 Hz (auto sensing) Input voltage range for main operations 160 - 280V Input voltage adjustable range for mains operation 100 - 280V Other Input Voltages 220,240 Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Included Battery Modules 2 Typical recharge time 2.50 hour(s) Replacement battery cartridge RBC44 Typical Backup Time at Half Load 15.4 minutes (1750 Watts) Typical Backup Time at Full Load 5.0 minutes (3500 Watts) Runtime Chart Smart-UPS RT Extended Run Options APC Smart-UPS RT 5000VA RM 230V Communications & Management Interface Port(s) DB-9 RS-232,RJ-45 10/100 Base-T,Smart-Slot Pre-Installed SmartSlot™ Cards AP9619 Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm Emergency Power Off (EPO) Yes Surge Protection and Filtering Surge energy rating 480 Joules Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 Shipping Height 347.00 mm Operating Environment 0 - 40 °C Operating Relative Humidity 0 - 95% Operating Elevation 0-3000 meters Storage Temperature -15 - 45 °C Storage Relative Humidity 0 - 95% Storage Elevation 0-15000 meters Audible noise at 1 meter from surface of unit 55 dBA Online Thermal Dissipation 1040.00 BTU/hr Regulatory Approvals C-tick,CE,EN 50091-1,EN 50091-2,EN 55022 Class A,EN 60950,EN 61000-3-2,GOST,VDE Standard Warranty 2 years repair or replace,optional on-site warranties available,optional extended warranties available
|
|
 |
 |
 |
 |
|
 |

|