You are here: Home > Shop Brands > Honeywell Security & Communications > Honeywell Expansion Modules & Accessories > Accessories
We found 27 results matching your criteria.
Accessories
Sort By:
Page of 3
Ademco / Honewell 1321 16.5 Volt 25VA Transformer Ademco / Honewell 1322/TF3 12 Volts/20 VA Transformer

This Transformer will operate any Ademco alarm system using 16.5 V AC 25VA.

General Information

Part Number1322/TF3
Brand NameAdemco
ManufacturerHoneywell International, Inc
Manufacturer Part Number1322/TF3
Product Model1322/TF3
Product TypeStep Down Transformer
UPC781410162792
Weight0.7 lbs

Miscellaneous


CompatibilityAdemco AD12612 Auxiliary Power Supply / Battery Charger

Power Description


Frequency60 Hz
Input Voltage110 V AC
Output Voltage12 V AC

Technical Information


Power Rating20 VA.
Ademco / Honeywell 1361 AC Transformer 16.5V/ 40VA Ademco / Honeywell 4100SM - Serial Interface Module
Ademco 1361 AC Transformer 16.5V/ 40VA
  • Interface for printer for: VISTA-50P, VISTA-100, VISTA-128B and VISTA-128FB

  • Direct wire download interface for : 4140XMP, VISTA-40, VISTA-50P, VISTA-100, VISTA-128B and VISTA-128FB

  • Ademco / Honeywell 4297 - Isolation / Extender Module Ademco / Honeywell 6220BB - Battery Backup for 6220 Series Security System Printers
    >Isolation / Extender Module

    The 4297 V-Plex Loop Isolation/Extender Module offers dual benefits for commercial applications. As an isolation module, the 4297 allows installers to group selected zones on one loop. For example, fire and burglary zones may be grouped separately; essentially isolating one from another. This isolation feature prevents failure in one loop from compromising the integrity of any other loop. The 4297 Module also gives installers the flexibility to extend system-wide wiring capability, from approximately 4000 ft to 8000 ft., without the added expense of additional hardware or control panels.

    • Isolate open and short circuit faults from main V-Plex loop
    • Provides additional V-Plex loop current
    • V-Plex loop isolation between primary and extended loop
    • Fully supervised
    • Separate DC input, no current drain from primary V-Plex loop
    • Monitors DC power input

    On-site printing has never been more practical. ADEMCO’s 6220 series of security system printers are a perfect complement to your fire, burglary or access control systems. These printers are feature-rich yet compact, simple to operate and cost effective.

    Practibility is key to ADEMCO, there is no need to worry about thermal paper - ADEMCO’s 6220 series of printers use “off-the-shelf” adding machine paper.

    The 6220 Series printers install quickly. Their small footprint allows for easy placement on any surface, no fancy printer stands are required. A handy wall mount bracket is supplied for convenient mounting of the printer next to the control cabinet. Simply connect the printer to the control’s serial or parallel port (cable not included), plug in the wall mount transformer, turn on power and you’re done. A4100SM Module (including cable) is required for use with ADEMCO VISTA controls.

    Ademco / Honeywell 6220S - Printer, Serial-Cable connection Ademco / Honeywell AD12612 - Auxiliary Power Supply / Battery Charger  1.2 A

    On-site printing has never been more practical than with Honeywell’s 6220 Series of security system printers. A perfect complement to your fire, burglary or access control systems, these feature-rich printers are compact, simple to operate and cost-effective.

    The quick-install 6220 Series contains small footprints for easy placement on any surface. A hand wall mount bracket is supplied for convenient mounting.

    FEATURES:

    • Burglary, fire and access control
    • Portable for keeping service/inspection records
    • Printing of programming/setup
    • Event logging
    • Permanent audit trail/records
    • System test and inspection
    • Service and diagnostics
    • Sales demos
    • Works with any product with a R232 (serial) port
    • Medical
    • Refrigeration
    • Inventory control
    • QA test results
    • Automotive diagnostic results
    • Hard copy credit card verification
    • Remote message printer

    Features:
  • Provides 6 or 12 VDC (6 or 12 volt operation)
  • 1.2 Amps continuous output to power devices
  • Transformer purchased separately
  • Factory preset at 13.6 VDC, with the jumper set to supply 12 volts DC

    Specifications:
    Transformer required:
  • For 6 volt operation: use 12VAC, 20 VA (Model 1322/TF3)
  • For 12 volt operation: use 16.5 VAC, 40 VA (Model 1361)
    Battery:
  • Supports a standard 4 AH gel cell battery
    Fuse:
  • 3 Amp Fast-blow Fuse
    Board Dimensions:
  • 4" x 2" x 1 3/4"
  • Ademco / Honeywell FSA-24 - 24-Zone LED Fire System Annunciator Ademco / Honeywell FSA-8 - 8-Zone LED Fire System Annunciator
    For Use With Controls Supporting Fire System Annunciator Connection Via Keypad Lines
    CAN ONLY BE USED WITH NEW VISTAFB SERIES PANELS
    CAN NOT BE USED WITH NEW VISTA-9 VERSION CONTROLS PANELS

    The ADEMCO 8-Zone LED Fire System Annunciator FSA-8, and 24-Zone LED Fire System Annunciator FSA-24, are add-on accessories that can be used with certain VISTA controls to provide the ability for a fire response unit to identify quickly and easily the point/zone of a fire. The LED's may also be used to annunciate other functions like monitoring door, critical equipment, etc.

    A maximum of 4 FSA modules, in any combination, can be supported by the system. Each FSA module must use the ECP Bus, keypad-type protocol, and can support up to 24 LEDs dependent upon model selection. In addition, the FSA module provides power and system status with LEDs and control via Silence/Reset and Test buttons. An optional Fire System Annunciator Keyswitch Module (FSAKSM) is available to function in a manner similar to the Silence/Reset button of the FSA module. The difference between the Silence/Reset button and the FSAKSM is that when installed, the FSAKSM will unconditionally Silence and then Reset the Fire Partition, while the Silence/Reset button can be restricted from silencing or resetting the fire alarm system (dependent upon program selection. See “RST FIRE PTN”).

    Since the ECP bus is used to connect the VISTA control to the FSA modules, any supported VISTA keypad may be located in proximity to the FSA module connecting to the same ECP bus. The maximum FSA system will consist of 4 FSA modules, 4 Keyswitch modules, and 4 keypads.

    Up to 4 FSA modules may be located in different locations but displaying the same information via the LEDs. Alternately, they may be located in the same physical location but displaying the status of up to 96 unique zones.

    Features:

    • 8 or 24 LED annunciators with sounder
    • Power and trouble LED's
    • Silence and reset switch
    • Lamp test switch
    • Fully supervised
    • Operates on Commercial VISTA Panel keypad bus
    • Up to four FSA-8 or 24 led annunciators per system
    • Optional Key-Reset Switch

    SPECIFICATIONS:

  • Physical Dimensions: 8" W x 4" H x 3/4" D
  • Electrical:
    – Input Voltage: 12 VDC
    – Current: 35mA idle, 65mA all LEDs lit and sounder on
  • For Use With Controls Supporting Fire System Annunciator Connection Via Keypad Lines
    CAN ONLY BE USED WITH NEW VISTAFB SERIES PANEL
    CAN NOT BE USED WITH NEW VISTA-9 VERSION CONTROL PANELS

    The ADEMCO 8-Zone LED Fire System Annunciator FSA-8, and 24-Zone LED Fire System Annunciator FSA-24, are add-on accessories that can be used with certain VISTA controls to provide the ability for a fire response unit to identify quickly and easily the point/zone of a fire. The LED's may also be used to annunciate other functions like monitoring door, critical equipment, etc.

    A maximum of 4 FSA modules, in any combination, can be supported by the system. Each FSA module must use the ECP Bus, keypad-type protocol, and can support up to 24 LEDs dependent upon model selection. In addition, the FSA module provides power and system status with LEDs and control via Silence/Reset and Test buttons. An optional Fire System Annunciator Keyswitch Module (FSAKSM) is available to function in a manner similar to the Silence/Reset button of the FSA module. The difference between the Silence/Reset button and the FSAKSM is that when installed, the FSAKSM will unconditionally Silence and then Reset the Fire Partition, while the Silence/Reset button can be restricted from silencing or resetting the fire alarm system (dependent upon program selection. See “RST FIRE PTN”).

    Since the ECP bus is used to connect the VISTA control to the FSA modules, any supported VISTA keypad may be located in proximity to the FSA module connecting to the same ECP bus. The maximum FSA system will consist of 4 FSA modules, 4 Keyswitch modules, and 4 keypads.

    Up to 4 FSA modules may be located in different locations but displaying the same information via the LEDs. Alternately, they may be located in the same physical location but displaying the status of up to 96 unique zones.

    Features:

    • 8 or 24 LED annunciators with sounder
    • Power and trouble LED's
    • Silence and reset switch
    • Lamp test switch
    • Fully supervised
    • Operates on Commercial VISTA Panel keypad bus
    • Up to four FSA-8 or 24 led annunciators per system
    • Optional Key-Reset Switch

    SPECIFICATIONS:

  • Physical Dimensions: 4" W x 4" H x 3/4" D
  • Electrical:
    – Input Voltage: 12 VDC
    – Current: 35mA idle, 65mA all LEDs lit and sounder on
  • Ademco / Honeywell UVS-QM - Universal Voice System:  UVCM Control Module + UVST	Universal Voice Station - UVSQM Ademco / Honeywell VA8201 - Alpha Pager Module (APM)
    Honeywell’s new Universal Voice System (UVS) helps you increase the value of every sale by adding an entirely new level of comfort and protection to your customers’ lives. The Universal Voice Control Module (UVCM) connects quickly and easily to a VISTA control and one standalone intercom station (UVST)—expanding into a powerful indoor/outdoor home communication system*.

    Two-way audio verification technology significantly reduces false alarms, and lifestyle-enhancing convenience features including an intercom, baby monitor and speakerphone simplify your customers’ lives while providing increased peace of mind. The optional outdoor cover (UVST/ODC) fits over the UVST station for use as an entranceway visitor screening station.

    * with the addition of intercom stations (up to seven)

    Features

    Audio Alarm Verification

    • Two-way voice communication with the central station in the event of an alarm

    Intercom

    • Broadcast a message to all stations in the home
    • Hold a private conversation between two stations
    • With the outdoor station, answer the front door without opening it to strangers
    • With a touchtone phone, the consumer can conduct a two-way voice conversation with someone on the premises

    Speakerphone

    • Broadcast the ringing of your phone over the stations
    • Answer calls from any station
    • Transfer a caller to another inside station
    • Hands free conversation between stations
    • Hands free conversation on incoming phone calls
    • Supports call waiting

    Audio System

    • Any station can become a baby monitor
    • Connect to a stereo input for music throughout the home
    • Security messages annunciate over the stations with a 4286 VIP Module

    Specifications:

    Physical:

    UVST Dimensions:

  • 5-1/8" H x 2-3/4" W x 1-1/2" D

    UVCM Dimensions:

  • 10" H x 10" W x 3" D

    Electrical

    UVST Ratings:

  • Operating Voltage: 9VDC to 14VDC
  • Current Drain: 10mA idle/70mA active
  • Wire Run Length: Home run 22AWG, 4 conductor cable back to UVCM, 200 feet maximum
  • Temperature Range: 14° F to 140° F (-10° C to +60° C)
  • Maximum Stations: Supports up to seven stations total. Up to two stations may be used outside.UVCM Control Module + UVST Universal Voice Station

    UVCM Ratings

  • Operating Voltage: 10VDC to 14VDC
  • Current Drain: 60mA idle/110mA active
  • Alpha Pager Module

    The VA8201 Alpha Pager Module (APM) provides the VISTA-128BP/128FBP and VISTA-250BP/250FBP control panels with alpha paging, parallel printer output, serial printer output and or home/facility automation control functions using a RS232 bi-directional communications protocol. The APM transmits alphanumeric security control panel dependent messages to the paging service using Telocator Alphanumeric Protocol.

    FEATURES:
    • Alpha Paging via Telocator Alphanumeric Protocol (TAP)
    • Shares same telephone line as alarm control panel
    • Parallel printer output
    • Serial output for use with serial printer or home/facility automation control
    • Easily mounts near control panel using bracket interface K5350
    • RS232 bi-directional communications protocol

       
     
    Accessories
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please