Features: - 6 programmable zones, 3 keypad zone, plus duress
- Zone 5 can be supervised fire using four-wire smoke detectors
- End of line resistor supervision on all zones for normally open or closed contacts
- Normal response, 400 msec, on all zones, one zone can be 10 msec.
- Zone types: entry/exit, perimeter, interior follower, day trouble/night alarm, 24 hour silent panic, 24 hour audible panic, 24 hour auxiliary, fire, with and without timeout
- Interior zone bypassed with STAY and INSTANT functions
- Zone restore reporting at sounder time-out if zone restored or at next system disarming
Valuable End-User Features: - Audible Exit Warning
- All keypads have an English lan guage display and a 4-wire con nection to the control.
- Keyswitch arming with status indication and tamper protection
- Test mode checks sounder, generates communicator test report; System can be walk tested
- 7 user codes consisting of 1 master code and 6 secondary codes
- Swinger suppression - 10 maximum number of alarms and trouble reports permitted per armed period or unlimited
- Individual bypass by zone
- Forced Bypass - single bypass entry for all zones that are faulted
- Fire alarm sounding turned off by single entry of OFF key
- Chime mode on entry/exit and perimeter zones
- Quick arming requires only a 2 key entry for an arming mode, if enabled. Reports as User 0
- Interior zone bypassed with STAY and INSTANT arming
- INSTANT and MAXIMUM mode cancels entry delay
- Entry delay eliminated with MAXIMUM arming with interior protection on
- Three keypad activated panic zone
- Entry time: 0, 20, 30 or 45, 60, 90 seconds
- Exit time: Entry time plus 15 seconds
- Alarm cut-off time: 4, 8, 12, 16 minutes or no time-out
- Extra large cabinet with removable door for wiring ease
Security Dealer Features: - Built-in alarm relay, SPST: steady output for burglary/audible emergency and pulsed for fire
- Pre-alarm, trouble and alert sounder built-in into keypads
SPECIFICATIONS: Communication: - Split/Dual Reporting
- Daily, Weekly or Monthly test
- Touchtone or pulse dial
- Formats:
- Honeywell contact ID - Honeywell 4+2 Express: 10 characters/sec. DTMF (Touchtone) data tone, 1400/2300 Hz ACK, 1400 Hz kissoff, checksum verification - Honeywell Low Speed: 10 pulses/sec, 1900 Hz data tone, 1400 Hz ACK/kissoff - Radionics: 20 pulses per second, 1800 Hz data tone, 2300 Hz ACK/kissoff - 3+1, 4+1, and 4+2 reporting in slow speed formats
- Dual telephone numbers
- Back-up reporting: 8 attempts made to primary and another 8 attempts to secondary telephone number
- Expanded reporting:
- alarms, restorals, bypasses and trouble by zone; open/close by user - Hexadecimal reporting
- 4-digit PABX code and 12-digit telephone number
- True dial tone detection
- Double pole line seizure
- Communication delayed for 15 seconds on burglary zone (not panic or fire zones) if selected
- Control low battery report when battery reaches 11.2 -11.6 volts
- AC power loss report
Electrical: - Bell Supervision
- Auxiliary current: 500 mA, 12VDC, current limited
- Low battery shutdown: 9.8 - 10.5 volts
- Transformer: 16.5VAC, 25VA (Ademco No. 1321/TF2)
- Standby time: 7 hours with 400mA auxiliary load using a 12 volt, 4 Ah battery
- Battery charging voltage: 13.8 VDC
- Alarm current: 2.0 amps, 12VDC fuse protected
Programming: - Programmable through keypad in non-volatile EEROM memory
- Site initiated or remote download from an IBM compatible PC, Compass and CIA modem
- Account takeover protection prevents unauthorized takeover of your accounts
- Downloading security with: security code handshake, data encryption, operator access levels to files and functions, date/time stamping with operator ID
- Remote download capabilities: Change user codes Enter new program Upload resident control program
Accessories: - CE2X - LX2 -Code Encryptor LX2
Keypads: - 6150 Fixed English LCD 85mA/40mA
- 6148 Fixed English LCD 70mA/30mA
Agency Listings: - UL Residential Fire, Burglary and CSFM
|
|
 |
 |
 |
 |
|
 |

|