Home > Fire Alarms > Fire Alarm Control Panels >

 

Ademco / Honeywell V128FBP-PAK1 - VISTA-128FB 128-ZONE COMBINATION FIRE/BURGLARY CONTROL PANEL + 6160CR LED keypad + 5140DLM Dialer Module - V128FB-PAK1



Ademco / Honeywell VISTA-128FB PAK 1 - VISTA-128FB 128-ZONE COMBINATION FIRE/BURGLARY CONTROL PANEL + 6160CR LED keypad + 5140DLM Dialer Module - V128FB-PAK1


 

Our Price : $503.69

UPC Code: 781410196414

Product Code: V128FBP-PAK1

Qty:

Description
 
PowerPak includes:
  • VISTA-128FB Control
  • 6160CR Keypad
  • 5140DLM Dialer Module

    Designed to integrate seamlessly with CCTV, access control and Honeywell’s full range of fire and burglary components, the VISTA-128FB provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions and supports up to 128 zones/points using hardwired, wireless and addressable V-Plex technologies.

    A diverse line of Honeywell initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays support this extremely powerful control platform. The VISTA-128FB has been designed to mount quickly and easily in an attack resistant cabinet and is available in 12V and 24V models.

    FEATURES:
    • Supports addressable V-Plex access control points using VistaKey (1 to 8 doors)
    • Supports up to 15 doors of access control using VISTA Gateway Module (VGM)*
    • Supports CCTV applications with the new VistaView-100 CCTV switcher module
    • Identifies the point or zone of a fire or alarm, using the new FSA-8/FSA-24 Fire system annunciator
    • Stores up to 512 events and can accommodate 150 user codes
    • New E2 software simplifies programming
    • Easily programmed and maintained with newly upgraded Compass Downloader software
    • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones
    • Can control eight separate areas independently (8 partitions)
    • Two on-board notification (bell) circuits delivering 2.3A @ 12V or 3.4 amp @ 24V
    • Automatic smoke detector sensitivity maintenance testing
    * Connects to Honeywell's Passpoint Access Control Systems. Maximum 32 doors.

    CONTROL PANEL SPECIFICATIONS:

    Cabinet dimensions:
  • 18"H X 14.5"W X 4.3"D

    Environmental:
  • Storage temp: -14ฐF to 158ฐF (-10ฐC to 70ฐC)
  • Operating temp: -32ฐF to 122ฐF (0ฐC to 50ฐC)
  • Humidity: 85% RH

    EMI: Meets or exceeds the following requirements:
  • FCC Part 15, Class B Device
  • FCC Part 68
  • IEC EMC Directive

    Agency Listings: Burglary
  • UL609 Grade A Local Mercantile Premises and
  • Mercantile Safe and Vault
  • UL611/1610 Grades A, AA, Central Station
  • UL365 Grades A, AA Police Connect

    Fire:
  • UL864 FPA72 Local, Central Station and Remote Station
  • Factory Mutual
  • California State Fire Marshal
  • MEA
  • UL985

    Additional Features:
  • Notification Appliance Circuits (two)
  • Programmable
  • Temporal code compliant
  • Individually silenceable
  • Programmable on-board auxiliary relay
  • SIA false alarm reduction features:
  • Exit Error Logic
  • Exit Delay Reset
  • Cross Zoning
  • Call Waiting Defeat
  • Recent Close Report
  • Supports commercial hardwired, addressable V-Plex polling loop and wireless zones
  • Hardwired zones:
    – Provides nine style B hardwired zones
    – EOLR supervised for Fire and UL burglary installations
    – Supports N.0 or N.C. sensors
    – Individually assignable to one or all eight partitions
    – Up to 16 two-wire smoke detectors each zone 1 and 2 (32 total)
    – Up to 50 two-wire glass break detectors on zone eight
  • Patented addressable V-Plex polling loopV-Plex technology:
    – Supports up to 120 two-wire zones/points
    – Global polling technology for faster processing
    – Increased current draw capacit (128mA)
    – Supervised by panel
    – Individually assignable to partitions, notification circuit (bell) output or aux relay
    – 4,000 ft capability without the use of shielded cable
    – Extender/Isolation bus module
    – Two-wire smoke detector zone/group expansion module adds two or four zones
    – Eight zone – Class A and B Extender Module
    – One zone supervised Contact Monitor Module
  • UL Listed wireless expansion
    – Supports up to 128 wireless zones using 5881 Receiver
    – Supervised by control for check-in signals
    – Tamper protection for transmitter
    – Individually assignable up to eight partitions
    – Supports UL864 FPA approved wireless smoke\ndetectors
  • Access control integration
    – Full integration with PassPoint
    – Access Control System Complete Gateway in access functions
  • Event reporting
  • Local printer of access or VISTA related event
  • Scheduled uploading of events to central station
  • Stored events for one call retrieval
  • Communication
    – Phone mapping by zone response type
    – Supports VIP Interactive Phone Voice Module
    – Panel operation during download
    – Uploading equipment list to central station
    – Communication to PassPoint via Vista Gateway Module (VGM)

    Applications: Supported by a diverse line of Honeywell initiating devices, the powerful VISTA-128FB is the ideal integrated fire and burglary control for applications where a higher level of security is necessary including medical and professional buildings, supermarkets, churches and synagogues, office buildings, schools, universities, strip malls, larger residences and factory or warehouse environments.

    Installation: The VISTA-128FB alarm system has been designed to mount both quickly and easily in an attack resistant cabinet. It meets all applicable requirements for UL commercial burglary installations.

    Electrical Specifications:
  • Primary power:
    – 18 VAC@ 72 VA No. 1450
    – Quiescent current draw:
    – 350mA
  • Backup battery
    – 12VDC, 12AH min to 34AAH max
    – Lead acid battery (gel type)
  • Alarm power
    – 12VDC, 1.7A max for each notification (bell) circuit output
  • Aux. standby power
    – 12VDC, 1A max
  • Total power
    – 2.3A at 12VDC, 3.4A at 24VDC from all sources
  • Standby time
    – 24 hours with 1A standby load or 60 hours with 205mA max standby load using 34AAH battery
  • Fusing
    – Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited.
  • Main dialer
    – Line seize:
    – Double Pole

    Ringer equiv.:
  • 0.713

    Formats:
  • ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics

  • Share your knowledge of this product with other customers... Be the first to write a review

    Browse for more products in the same category as this item:

    Fire Alarms > Fire Alarm Control Panels
    Shop Brands > Honeywell Security & Communications > Honeywell Security Kits > Combination Fire / Burglary
    Shop Brands > Honeywell Security & Communications > Honeywell Fire Systems & Accessories
    Shop Brands > Honeywell Security & Communications > Honeywell Security Kits
    Shop Brands > Honeywell Security & Communications
    Fire Alarms
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please