The VISTA-250BP is an eight partition, eight to 250 zone UL listed commercial burglary control panel that meets the demanding requirements for today’s medium-sized commercial installations while simplifying the end-user operation. The VISTA-250BP is ideal for locations like large office complexes, medical clinics, bank branches, medium-to-largesized distribution centers, warehouses, auditoriums, school campuses and other large public buildings. This panel provides system scalability and utilizes conventional V-Plex and wireless zone expansion. The VistaKey access control system, Vistaview-100 and Optiflex allow seamless integration with this powerful commercial platform. The VISTA Navigator Controller/Reporter allows on-site remote work station system operation and management. The VISTA-250BP interfaces with AlarmNet GSM/iGSM Communicators even without POTS lines. Features - Provides nine on-board style-B hardwired zones
- Supports up to 241 additional zones using a built-in polling (multiplex) loop interface
- Supports up to 250 wireless zones using 5881 type RF receiver (fewer if using hardwired and/or polling loop zones)
- Provides 1 power-limited bell circuit delivering 1.7Amp (max) at 12Vdc
- Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control
- Accommodates 250 user codes with seven authority levels per partition
- Accommodates 32 keypad macro commands per system
- Keeps a log of up to 1,000 events
- VISTAView-100 CCTV support
- Supports up to 16 two-wire smoke detectors on zone 1
- Supports up to 50 latching-type glassbreak detectors on zone 8
- Zone 7 may be used for keyswitch arming/disarming
- Integrates with WIN-PAK access control systems to provide increased users, event log and scheduling
- Supports V-Plex addressable VISTAKey access control (up to 15 doors and 500 cards)
- Easily programmed and maintained by the newly upgraded Compass Windows-based downloader
- Supports up to 96 programmable relays
- Supports the ADEMCO 4286 VIP Module
- Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP- 01-2000 order part number VISTA- 128SIA
New Enhancements: - Upload/Download using AlarmNet devices
- CO detector support
- Two-way RS232 (facility automation software support) optional
- Supports eight numeric pager numbers
- Supports touchscreen Advanced User Interface (AUI)
- Smoke Detector Reset at keypad
- Panel linking up to eight panels
- Quick Exit
- Group Bypass
- Arm Faulted
- Event Arming
- Scheduled check-in
- Arm Stay by group
Additional Features Additional Features Basic Hardwired Zones - EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations)
- Individually assignable to one of 8 partitions
- Up to 16 two-wire smoke detectors on zone 1
- Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be supervised with an EOL device). Listed for residential fire only.
- Up to 50 two-wire latching glassbreak detectors on zone 8
Polling Loop Expansion Supports up to 241 additional zones using a built-in polling (multiplex) loop interface. Polling loop zones have the following characteristics: - Must use RPM (Remote Point Module) devices
- Supervised by control panel
- Individually assignable to one of 8 partitions
- Supports VSI module operation
- Supports 4297 Expander Module
- Maximum wiring distance - 12, 000 feet
Wireless Expansion Supports up to 250 wireless zones using 5881 type RF receiver (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics: Supervised by control panel for check-in signals (except certain nonsupervised transmitters) Tamper protection for supervised transmitters Individually assignable to one of eight partitions Scheduling Provides the following scheduling capabilities: Open/Close Schedules (for control of arming/disarming and reporting) Holiday Schedules (allows different time windows for open/close schedules) Timed Events (for activation of relays, auto-bypassing and unbypassing, autoarming and disarming, etc.) Access Schedules (for limiting system access to users by time) Eight Partitions Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include: A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads) All zones assignable to one of eight partitions Keypads assignable to one of eight partitions or to Master partition 9 to view system status Ability to assign relays to one or all eight partitions Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option) Certain system options selectable for each partition, such as entry/exit delay and subscriber account number New Enhancement: Panel Linking. Panel Linking allows multiple control panels to be networked together and controlled from any keypad in the system: Control multiple zones, partitions, buildings from a central location Check status, arm and disarm any partition from any keypad in the system (based on user’s authority level) Users can have a different authority level in each partition and access to different partitions in each panel Global Arming - users can arm and disarm all the partitions in all the panels they have access to, with one set of keystrokes Applications: The VISTA-250BP control is well suited for a variety of applications as a burglary control. A diverse line of ADEMCO initiating devices support this extremely powerful control. Some of the applications supported are medical and professional buildings, supermarkets, churches or synagogues, office buildings, schools, universities, strip malls, larger residences and factory or warehouse environments. Installation: The VISTA-250BP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for ULCommercial Burglary installations, use the VISTA-ULKT kit when an attack resistant enclosure is required. Agency Listings (all future), Burglary: UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault UL611/UL1610 Grades A, AA Central Station UL365 Grades A, AA Police Connect UL985 Household Fire UL1635 - Digital Alarm Communicator System Units UL1023 Household Burglar Alarm California State Fire Marshall (CSFM) CAN/ULC - S303 CAN/ULC - S304 CAN/ULC - S545 CAN/ULC - S1023 Specifications—Electrical: Voltage Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada) or 4300 transformer (for X- 10 installations) rated 16.5VAC, 40 VA Alarm Sounder Output:10VDC- 13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations) Auxiliary Power Output: 9.6VDC- 13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended Standby Time: 4 hours min. with 750 mA aux. load using 7 AH battery Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). Main Dialer: Formats Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO Contact ID, Sescoa and Radionics Low Speed Line Seize: Double Pole Ringer Equivalence: 0.7B Cabinet dimensions: 12-1/2" W X 14 1/2" H X 3" D Auxiliary Devices: 4204 – Relay Module, four form C contacts 4204CF – two supervised output circuits 5881 Series – RF Receiver supporting 5800 wireless detectors 6160/6139 – Alpha Keypad/Annunciator 6220S – System Printer used with 4100SM serial module VA8200 – (PLM) Panel Linking Module VA8201 – (APM) Alpha Paging Module Two-wire smoke detectors: conventional System Sensor smoke detectors Horn/Strobes: System Sensor Notification Appliances Manual pull stations: 5140MPS-1 5140MPS-2 V-Plex (addressable) devices: 4101SN Single Relay/Zone Module 4190SN Remote Point Module – two zones 4193SN Two Zone Serial Interface Module 4208U Loop Expansion Module – eight zones 4208SNF Class A/B Expander Module 4209U Group Zoning Module – two/four zones VSI Module 4293SN One Zone Serial Interface Module 4297 Isolation/Extender Module VPlex (addressable) smoke detectors 5192SD 5192SDT Passive infrared detectors: 998MX 4275EX-SN 4278EX-SN QUEST2260SN V-Plex (addressable) contacts: 4939SN-WH 4944SN-WH 4959SN, 9500SN V-Plex Glassbreak detectors: FG1625SN VISTA interactive phone module: 4286 Voice Module Long range radio: Long Range Radio 7845GSM, 7845iGSM, 7845i Upgraded software: Upgraded Compass Downloader Windows compatible Wireless devices: 5804 – Wireless Key 5804BD – Bi-directional Key 5804BDV – Bi-directional with voice 5816 – Door/Window Transmitter 5819 – Shock Sensor 5827BD – Bi-directional Keypad 5849 – Glassbreak Detector 5890PI – PIR Access control: VISTAKey V-Plex (addressable) Access Control VISTAKey-SK Starter Kit VISTAKey-EX Expansion Kit VGM VISTA Gateway Module to PassPoint Access Control (Northern Computers) CCTV: CCTV – VISTAView-100 CCTV Switcher Module Commercial Wireless Devices: 5808W3 – Wireless Smoke Detector** 5809 – Wireless Heat Detector 5817CB – Commercial UL Burglary, Universal Contact Monitoring Transmitter* 5869 – Commercial UL Wireless Hold-up Button* 5881ENHC * When used with 5881ENHC receiver. ** Not listed for commercial use with VISTA-250BP, residential listing only.
|
|
 |
 |
 |
 |
|
 |

| Accessory or Possible Replacement |
|
|
|

|