Ademco Honeywell Vista Control Panels
Sort By:
Page of 4
Ademco / Honeywell  VISTA-20PUL - Commercial Burglary Alarm Control Panel - VISTA20PUL Ademco / Honeywell V10P50RFATPK - V10P Attack Pack: + VISTA-10P control panel + 6150RF Deluxe Fixed English Integrated Keypad/Receiver  + 998PI 40 LB Pet Immune Motion Sensor  + Wave 2 2-tone sounder  + 467 Battery
Honeywell’s high capacity, feature-rich VISTA-20PUL is a UL Listed, economical control/communicator that supports up to48 zones of protection using basic hardwired, wired expansion, and/or wireless zones.

The VISTA-20PUL also includes Ethernet uploading and downloading capability for Internet and Intranet use via Honeywell’s 7845i or 7845i-ENTcommunications products. The panel’s installation advantages,appealing end-user benefits and robust system capacity make the value-priced VISTA-20PUL an ideal choice for light commercial applications.

  • Ethernet uploading and downloading capability for Internet and Intranet use via 7845i or 7845i-ENT
  • Supports four graphic touchscreen keypads
  • Wireless keys can be programmed without using zones
  • Eight on-board hardwired zones standard (15 when Zone Doublingfeature is used)
    – 40 hardwired expansion zones
    – 40 wireless expansion zones
  • Two low current on-board trigger outputs
  • 100 Event Log viewable at system keypads with time/date stamp
  • 48 system user codes assignable to either partition
  • Expandable to 48 total zones when used with hardwired and/or wirelessexpansion modules
  • Two independent partitions plus a common partition – Global Arming from any system keypad
    – Goto function to view or operate one partition from the other
    – Separate partition account numbers
  • 16 output devices
    – Relays (Model 4204 RelayModules, or 4229 ExpansionModule), and/or
    – X-10 devices (when used with a 4300 Transformer)
  • Four installer configurable zone types allows the installer to create custom zone types by assigning all zone attributes
  • Supports four-wire, and up to 16 two-wire smokes
    – Works with Sentrol CleanMe maintenance signal
  • Multiple actions on output devicesdepending on system “state”
    – Turns lights off when system arms
    – Turns the same light on when system disarms
    – Flashes same lights when system is in alarm condition
  • Built-in phone line cut monitor with programmable delay and annunciation options
    – Display on system keypads
    – Trigger local sounders
    – Trigger system bell

    Security Dealer Features Automatic System Load Shed
    – During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries Dynamic Signaling
    – Reduces redundant reporting tothe central station when multiple reporting methods are used; i.e.digital dialer and AlarmNet radio The VISTA-20PUL complies to the following listings (listed at UL as VISTA 20P & UL-KT):

    US Standards: UL LISTINGS
    UL 985 - Household Fire Warning System Units
    UL 1023 - Household Burglar-Alarm System Units
    UL 609 - Local Burglar Alarm Units and Systems
    UL 365 - Police Station Connected Burglar Alarm Units and Systems
    UL 1610 - Central Station burglar Alarm Units
    UL 1635 - Digital Alarm Communicator System Units

    Canadian Standards: CUL LISTINGS
    CAN/ULC-S303-M91-STANDARD for Local Burglar Alarm Units and Systems.
    ULC Subject C1023-Standard for Household Burglar Alarm System Units.
    CAN/ULC-S545-M89-Standard for Residential Fire Warning System Control Units.
    CAN/ULC-S304-M88-Standard for Central and Monitoring Station Burglar Alarm Units.
    Canadian Electrical Code, Part I.


    Electrical Specifications:

  • Aux. power: 12VDC, 600mA maximum
  • Seven hour standby at 400mA aux. load with four amp hour battery
  • 16.5VAC/25VA transformer
  • Alarm output: 12VDC, 2.0 amps max.
    - For UL listed installations, combined aux. and alarm output cannot exceed 700mA

    Output Control:
  • Supports up to four relay boards (up to 16 relays)
  • Optional X-10 transformer/interface (part no. 4300) may be used to control up to 16 X-10 receiving devices

    Zones:
  • Eight hardwired zones (15 with zone doubling)
  • Selectable response: 10msec, 350msec, 750msec
  • Assignable to any partition
  • 20 selectable zone types plus four configurable zone types
  • Programmable swinger suppression

    Expansion Devices:
  • 4219 – Eight hardwired zones – 16mA
  • 4204
    - Up to four relays
    - 15mA standby (each active relay draws an additional 40mA)
  • 4229 – Eight hardwired zones and two relays – 36mA (each active relay draws an additional 40mA)

    Accessories:
  • 7845i Internet Communicator
  • 7845i-ENT Enterprise Internet Communicator
  • 4286 VIP Voice Module
    - 220mA
  • 5881ENL supports up to eight zones
    - 60mA, 5881ENM supports up to 16 zones
    - 5881ENH supports up to 48 zones
    - 50mA
  • 5883 Transceiver supports up to 40 zones
    - 80mA
  • Supports Eagle 1225 and 1221 boards

    Keypads:
  • 6160 Custom Alpha (required for programming)
    - 100mA
  • 6160V Custom Alpha Voice
    - 100mA
  • 6150 Fixed English LCD
    - 85mA/40mA
  • 6150V Fixed English Voice LCD
    - 85mA/40mA
  • 6150RF Fixed English RF LCD
    - 85mA/40mA
  • 6148 Fixed English LCD
    - 70mA/30mA
  • 6270 Graphic Touchscreen
  • 8132 Advanced User Interface

    Smoke Detectors:
  • Supports up to 16 two-wire smoke detectors
  • Supports four-wire smoke detectors

    Agency Listings:
  • UL Residential Fire, Burglary and CSFM
  • UL 985 - Residential Household Fire Warning System Units
  • UL 1023 - Residential Household Burglar Alarm System Units
  • UL 609 - Local Burglar Alarm Units and Systems
  • UL 365 - Commercial Police Station Connected Burglar Alarm Units and Systems
  • UL 1610 - Commercial Central Station Burglar Alarm Units

    Communications:
  • 7845i Internet Communicator
  • 7845i-ENT Enterprise Internet Communicator
  • Touchtone or pulse
  • Formats supported: ADEMCO Contact ID , ADEMCO 4 + 2 Express , ADEMCO low speed , Sescoa/Radionics
  • 3 + 1, 4 + 1 and 4 + 2 reporting
  • Reporting capabilities: Split , Dual , Split/Dual - True dial tone detection
  • Low battery reports 11.2
    - 11.6VDC
  • AC loss and restoral reporting supported
  • This package includes:
    • VISTA-10P control panel
    • 6150RF Deluxe Fixed English Integrated Keypad/Receiver
    • 998PI 40 LB Pet Immune Motion Sensor
    • Wave 2 2-tone sounder
    • 467 Battery
    Ademco / Honeywell V250FBP-24 - VISTA-250FBP Commercial Fire/Burglary/ CCTV and Access Control Platform, 250 Zones, 24V Model - V250FBP24 Ademco / Honeywell VISTA-10P - VISTA PLUS Series Residential 22 Zone Control Panel only - VISTA10P
    24 Volt Model

    Designed to integrate seamlessly with CCTV, access control and Honeywell’s full range of fire and burglary components, the new VISTA-250FBP provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions and supports up to 250 zones/points using hardwired, wireless and V-Plex addressable technologies. A diverse line of Honeywell initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays are supported by this extremely powerful control platform. The VISTA-250FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. A revolutionary new feature called Panel Linking allows multiple partitions, panels and even buildings, to be armed, disarmed or have status checked…from one location!

    Features

    • Comes standard with eight hardwired zones, expandable to 242 V-Plex addressable points/zones or 250 wireless points/zones
    • Can control eight separate areas independently (eight partitions)
    • Supports Panel-Linking: Allows up to eight systems or buildings to be controlled from one central location (using VA8200)
    • Supports Commercial UL Wireless Fire and Burglar
    • Stores up to 1,000 events and can accommodate 250 user codes
    • Supports V-Plex addressable VistaKey access control (up to 15 doors and 500 cards)*
    • Supports up to 16 doors of access control using Vista Gateway Module (VGM)*
    • Supports CCTV applications with the new VistaView-100 CCTV Switcher Module
    • Identifies the point or zone of a fire or alarm using the new FSA-8/FSA-24 Fire System Annunciator
    • Two on-board notification (bell) circuits delivering 2.3A @ 12V or 3.4A @ 24V
    • Automatic smoke detector sensitivity maintenance testing
    • Four-wire smoke reset using onboard J2 output trigger
    • Supports Dynamic Signaling for long range radio backup
    • Supports remote control via the Internet**
    • Supports Internet Alarm Reporting**
    • Supports Graphical User Interface consoles
    • Supports Alphanumeric Pager: up to eight different numbers using the VA8201
    • Notification Appliance Circuits (two):
      1. – Programmable
        – Temporal code compliant
        – Individually silenceable
    • Programmable on-board auxiliary relay
    • SIA false alarm reduction features:
      1. – Exit error logic
        – Exit delay reset
        – Cross zoning
        – Call waiting defeat
        – Recent close report
    • Supports commercial hardwired, addressable polling loop and wireless zones
    • Hardwired zones:
      1. – Provides eight style B hardwired zones
        – Supports N.O. or N.C. sensors
        – Individually assignable to any partition
        – Up to 32 two-wire smoke detectors each on zones one and two (64 total)
        – Up to 50 two-wire glassbreak detectors on zone eight
        – EOLR supervised for Fire and UL burglary installations

    * Connects to Honeywell Access’ PassPoint Access Control Systems. Maximum 32 doors.
    ** When used with AlarmNet-i.

    Additional Features

    • Patented addressable polling loop technology
      1. – Supports 242 two-wire zone points
        – Global polling technology for faster processing
        – Increased current draw capacity (128mA)
        – Supervised by panel
        – Individually assignable to partitions, notification circuit (bell) output or auxiliary relay
        – 4,000 ft. capability without the use of shielded cable
        – Extender/Isolation bus module
        – Two-wire smoke detector zone/group expansion module adds two or four zones
        – Eight zone – Class A and B extender module
        – Eight zone – Class B extender module
        – One zone supervised contact monitor module
    • UL Listed wireless expansion
      1. – Supports up to 250 wireless zones/points using 5881ENHC Receiver
        – Supervised by control for check-in signals
        – Tamper protection for transmitters
        – Individually assignable up to eight partitions
        – Supports UL864/NFPA approved wireless smoke detectors
    • Access Control Integration
        – Full integration with PassPoint Access Control System
    • Up to 15 doors using VistaKey Access Control
    • Event reporting
    • Local printer of access or VISTA related event
    • Scheduled uploading of events to the central station
    • Stored events for one call retrieval
    • Communication
      1. – Phone mapping by zone response type
        – Supports VIP Interactive Phone Voice Module
        – Panel operation during download
        – Uploading equipment list to the central station
        – Communication to PassPoint via VISTA Gateway Module
    • CCTV integration
        – Supports VistaView-100 ECP based CCTV switchers
    • Applications
    • Supported by a diverse line of Honeywell initiating devices, the powerful VISTA-250FBP is the ideal integrated fire and burglary control for applications where a higher level of security is necessary. Some examples of applications include: medical and professional buildings, supermarkets, churches, synagogues, schools, universities, strip malls, factories, warehouses, and larger residences.

    Installation:
    The VISTA-250FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations.

    Electrical Specifications:

  • Primary power: 18VAC @ 72VA ADEMCO No. 1451
  • Control Panel quiescent current draw: 300mA
  • Backup battery:
    – 12VDC, 12AH min to 34.4AH max
    – Lead acid battery (gel type)
  • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3A @ 12V
  • Aux. standby pwr: 12VDC, 1A max
  • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources
  • Standby time: 24 hours with 1A standby load using 34.4AH battery
  • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited
  • Optional 24-volt power supply, PS 24 supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputs

    Main Dialer:

  • Line seize: Double Pole
  • Ringer equiv.: 0.7B
  • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics
  • Dual phone line capability (using 5140DLM module)

    Cabinet Dimensions:

  • 18? H X 14.5? W X 4.3? D

    Environmental:

  • Storage temp: 14° F to 158° F (-10° C to 70° C)
  • Operating temp: 32° F to 122° F (0° C to 50° C)
  • Humidity: 85% RH
  • EMI: Meets or exceeds the following requirements:
    – FCC Part 15, Class B Device
    – FCC Part 68
    – IEC EMC Directive

    Agency Listings Burglary:

  • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault
  • UL611/1610 Grades A, AA, Central Station
  • UL365 Grades A, AA Police Connect

    Fire:

  • UL864/NFPA72 Local, Central Station and Remote Station
  • Factory Mutual
  • California State Fire Marshal
  • MEA
  • UL985

    Auxiliary Devices:

  • 4204 – Relay Module, four form C contacts
  • 4204CF – Two supervised output circuits
  • 5881 Series – RF receiver supporting 5800 wireless detectors
  • 6220S – System printer used with 4100SM serial module
  • 6160CR – Red Alpha Keypad
  • FSA-8 & FSA-24 annunciator modules
  • VA8200 – (PLM) Panel Linking Module
  • VA8201 – (APM) Alpha Paging Module

    Two-Wire Smoke Detectors Conventional:

  • System Sensor smoke detectors

    Horn/Strobes:

  • System Sensor Notification Appliances

    Manual Pull Stations:

  • 5140MPS-1
  • 5140MPS-2

    V-Plex (Addressable) Devices:

  • 4101SN Single Relay/Zone Module
  • 4190SN Remote Point Module – two zones
  • 4193SN Two Zone Serial Interface Module
  • 4208SNF Class A/B Expander Module
  • 4208U Loop Expansion Module
    – eight zones
  • 4209U Group Zoning Module
    – two/four zones
  • 4293SN One Zone Serial Interface Module
  • 4297 Isolation/Extender Module
  • VSI Module

    V-Plex (Addressable) Smoke Detectors:

  • 5192SD
  • 4192SD
  • 4192CP
  • 192SDT
  • 4192SDT
  • 4192CPM
  • 4192SDTM

    V-Plex Passive Infrared Detectors:

  • 998MX
  • 4275EX-SN
  • 4278EX-SN

    V-Plex (Addressable) Contacts:

  • 4939SN-WH
  • 4944SN-WH
  • 4959SN

    V-Plex Glassbreak Detectors:

  • FG1625SN

    VISTA Interactive Phone Module:

  • 4286 Voice Module

    Optional 24V Power Supply:

  • PS24 – 24V power supply – 3.4A

    Long Range Radio:

  • Long Range Radio 7720ULF-XX, 7835C, 7835CF, 7845C

    Upgraded software:

  • Upgraded Compass Downloader Windows compatible

    Wireless Devices:

  • 5804 – Wireless Key
  • 5804BD – Bidirectional Key
  • 5804BDV – Bidirectional with voice
  • 5816 – Door/Window Transmitter
  • 5819 – Shock Sensor
  • 5827BD – Bidirectional Keypad
  • 5849 – Glassbreak Detector
  • 5890 – PIR

    Commercial Wireless Devices:

  • 5808W3 – Photoelectric Smoke/Heat Detector
  • 5809 – Wireless Heat Detector
  • 5817CB – Wireless Commercial Transmitter
  • 5869 – Hold up Transmitter
  • 5881ENHC – Commercial Fire/Burg Receiver

    Access Control:

  • VistaKey V-Plex (addressable) Access Control
  • VistaKey-SK Starter Kit
  • VistaKey-EX Expansion Kit
  • VGM Vista Gateway Module to PassPoint Access Control
  • Pro-Watch
  • WIN-PAK (PE or SE)

    CCTV:

  • VistaView-100-CCTV Switcher Module

    Alarm Communications:

  • Graphical user interface with Internet capability
  • Internet Remote Control- Networking Module
  • Internet Alarm Communicator (7845i)
  • 7845GSM – Digital Cellular Communicator
  • 7845i-GSM – Internet and Digital Cellular Communicator
  • GSMCF/iGSMCF – Commercial Fire Communication Kits
  • CONTROL PANEL ONLY

    Honeywell’s feature-rich VISTA-10P is the industry’s most economical, versatile control and ideally suited for a wide range of applications. The six-zone panel significantly reduces dealer training and service call costs thanks to user-friendly features that make operation easier than ever, and increases upsell opportunities through its expansion capabilities and flexibility. 

    Features:
  • Six hardwired zones on board
  • 16 wireless expansion zones totaling 22 protection zones
  • Eight independent keyfob zones allow two wireless keys to be programmed without using any of the 22 zones
  • 32 Event log
  • 16 user codes
  • One configurable zone type allows installers to create their own custom zone type
  • Two on-board triggers
  • Four output devices using a 4204 relay module
  • Valuable End-User Features:
  • Flexible function keys allow single button arming
  • One programmable macro key
  • Viewable on system keypad display
    - Exit countdown
    - Time and date*
    - Event log*
  • Two schedules
    - Can activate relays on programmed times or on events
    - Latchkey reports to a pager
    - "User Access" time windows
  • Chime by zone
  • 4286 Phone Module allows system control from any touchtone phone
  • Four output devices with multiple actions per device
    - Turn lights on when system disarms with a 4204 relay
    - Flash same lights when system is in alarm with a 4204 relay

  • Electrical Specifications:
  • Aux. power: 12VDC, 600mA maximum
  • Seven hour standby at 400mA aux. load with four amp hour battery
  • 16.5VAC/40VA transformer
  • Alarm output: 12VDC, 2.0 amps max.
    - For UL listed installations, combined aux. and alarm output cannot exceed 700mA

    Output Control:
  • Supports multiple output devices, one 4204 and two triggers

    Zones:
  • Six hardwired zones
  • Selectable response: 10msec, 350msec, 750msec
  • 16 selectable zone types plus one configurable zone type
  • Programmable swinger suppression

    Expansion Devices:
  • 4204
    - Up to four relays
    - 15mA standby (each active relay draws an additional 40mA)

    Accessories:
  • 7845i Internet Communicator
  • 7845i-ENT Enterprise Internet Communicator
  • 7845GSMR Dual-Path Digital Wireless Communicator
  • 7845i-GSM Triple-Path Digital Communicator
  • 4286 VIP Voice Module
    - 220mA
  • 5881ENL supports up to eight zones
    - 60mA, 5881ENM supports up to 16 zones
    - 5881ENH supports up to 22 zones
    - 50mA
  • 5883 Transceiver supports up to 26 zones
    - 80mA
  • Supports Eagle 1225 and 1221 boards

    Keypads:
  • 6160 Custom Alpha (required for programming)
    - 100mA
  • 6160V Custom Alpha Voice
    - 100mA
  • 6150 Fixed English LCD
    - 85mA/40mA
  • 6150V Fixed English Voice LCD
    - 85mA/40mA
  • 6150RF Fixed English RF LCD
    - 85mA/40mA
  • 6148 Fixed English LCD
    - 70mA/30mA

    Agency Listings:
  • UL Residential Fire, Burglary and CSFM
  • ETL Residential Fire, Burglary

    Smoke Detectors:
  • Supports four-wire smoke detectors

    Communications:
  • 7845i Internet Communicator
  • 7845i-ENT Enterprise Internet Communicator
  • 7845GSMR Dual-Path Digital Wireless Communicator
  • 7845i-GSM Triple-Path Digital Communicator
  • Touchtone or pulse
  • Formats supported: ADEMCO Contact ID , ADEMCO 4 + 2 Express , ADEMCO low speed , Sescoa/Radionics
  • 3 + 1, 4 + 1 and 4 + 2 reporting
  • Reporting capabilities: , Split , Dual , Split/Dual - True dial tone detection
  • Low battery reports 11.2
    - 11.6VDC
  • AC loss and restoral reporting supported
  • Ademco / Honeywell VISTA-10PSIA - VISTA PLUS Series Residential 22 Zone Control Panel with SIA Approval - VISTA10PSIA Ademco / Honeywell VISTA-128B - Commercial Partitioned Burglary/CCTV and Access Control Platform - VISTA128B

    • All the same features as the VISTA-10P
    • UL approval for ANSI/SIA CP-01-2000

    Honeywell’s feature-rich VISTA-10P is the industry’s most economical, versatile control and ideally suited for a wide range of applications. The six-zone panel significantly reduces dealer training and service call costs thanks to user-friendly features that make operation easier than ever, and increases upsell opportunities through its expansion capabilities and flexibility.

    Features:
  • Six hardwired zones on board
  • 16 wireless expansion zones totaling 22 protection zones
  • Eight independent keyfob zones allow two wireless keys to be programmed without using any of the 22 zones
  • 32 Event log
  • 16 user codes
  • One configurable zone type allows installers to create their own custom zone type
  • Two on-board triggers
  • Four output devices using a 4204 relay module
  • Valuable End-User Features:
  • Flexible function keys allow single button arming
  • One programmable macro key
  • Viewable on system keypad display
    - Exit countdown
    - Time and date*
    - Event log*
  • Two schedules
    - Can activate relays on programmed times or on events
    - Latchkey reports to a pager
    - "User Access" time windows
  • Chime by zone
  • 4286 Phone Module allows system control from any touchtone phone
  • Four output devices with multiple actions per device
    - Turn lights on when system disarms with a 4204 relay
    - Flash same lights when system is in alarm with a 4204 relay

  • Electrical Specifications:
  • Aux. power: 12VDC, 600mA maximum
  • Seven hour standby at 400mA aux. load with four amp hour battery
  • 16.5VAC/40VA transformer
  • Alarm output: 12VDC, 2.0 amps max.
    - For UL listed installations, combined aux. and alarm output cannot exceed 700mA

    Output Control:
  • Supports multiple output devices, one 4204 and two triggers

    Zones:
  • Six hardwired zones
  • Selectable response: 10msec, 350msec, 750msec
  • 16 selectable zone types plus one configurable zone type
  • Programmable swinger suppression

    Expansion Devices:
  • 4204
    - Up to four relays
    - 15mA standby (each active relay draws an additional 40mA)

    Accessories:
  • 7845i Internet Communicator
  • 7845i-ENT Enterprise Internet Communicator
  • 7845GSMR Dual-Path Digital Wireless Communicator
  • 7845i-GSM Triple-Path Digital Communicator
  • 4286 VIP Voice Module
    - 220mA
  • 5881ENL supports up to eight zones
    - 60mA, 5881ENM supports up to 16 zones
    - 5881ENH supports up to 22 zones
    - 50mA
  • 5883 Transceiver supports up to 26 zones
    - 80mA
  • Supports Eagle 1225 and 1221 boards

    Keypads:
  • 6160 Custom Alpha (required for programming)
    - 100mA
  • 6160V Custom Alpha Voice
    - 100mA
  • 6150 Fixed English LCD
    - 85mA/40mA
  • 6150V Fixed English Voice LCD
    - 85mA/40mA
  • 6150RF Fixed English RF LCD
    - 85mA/40mA
  • 6148 Fixed English LCD
    - 70mA/30mA

    Agency Listings:
  • UL Residential Fire, Burglary and CSFM
  • ETL Residential Fire, Burglary Smoke Detectors
  • Supports four-wire smoke detectors Communications
  • 7845i Internet Communicator
  • 7845i-ENT Enterprise Internet Communicator
  • 7845GSMR Dual-Path Digital

    Wireless Communicator:
  • 7845i-GSM Triple-Path Digital Communicator
  • Touchtone or pulse
  • Formats supported: ADEMCO Contact ID , ADEMCO 4 + 2 Express , ADEMCO low speed , Sescoa/Radionics
  • 3 + 1, 4 + 1 and 4 + 2 reporting
  • Reporting capabilities , Split , Dual , Split/Dual - True dial tone detection
  • Low battery reports 11.2
    - 11.6VDC
  • AC loss and restoral reporting supported
  • ADEMCOs VISTA-128B is an 8-partition, UL/CUL Commercial Burglary Control Platform that supports up to 128 zones using basic hardwired, polling loop, and wireless zones. It also includes zones for supervision of bells,keypads, RF receivers, and relays. In addition, the control offers scheduling capabilities and allows certain operations to be automated by pressing a single button.

    The system has the capability to interface with an ECP Long Range Radio unit that can send Contact ID messages and an alphanumeric paging device. When connected to ADEMCOs PassPoint system (via the Vista Gateway Module), the VISTA-128B provides a fully integrated security and access control system.

    Applications

    The VISTA-128B is well suited for a variety of applications as a burglary control and is supported by a diverse line of ADEMCO initiating devices. Some of the applications supported are medical and professional buildings, supermarkets, churches or synagogues, office buildings, schools, universities, strip malls, larger residences and factory or warehouse environments.

    Installation

    The VISTA-128B has been designed to mount quickly and easily and meets all applicable requirements for UL/CUL-Commercial Burglary installations. Use the VISTA-ULKT kit when an attack resistant enclosure is required.

    FEATURES
    • Provides nine style-B hardwired zones
    • Supports up to 119 additional zones using a built-in polling (multiplex) loop interface
    • Can control up to eight separate partitions independently, each functioning as if it had its own separate control
    • Accommodates 150 user codes with seven authority levels
    • Supports up to 128 wireless zones using a 5881 type RF receiver (fewer if using hardwired and/or polling loop zones)
    • Supports the 5817CB Wireless Commercial Transmitter
    • Supports the 5869 Wireless Commercial Burglary Hold-up switch
    • Supports the 5881ENHC Wireless Commercial receiver
    • Accommodates 32 keypad macro commands per system
    • Keeps a log of up to 512 events
    • Supports up to 16 two-wire smoke detectors on zone 1
    • Supports up to 50 latching-type glassbreak detectors on zone 8
    • Integrates with PassPoint access control to provide increased users, event log, and scheduling
    • Supports V-Plex addressable VistaKey access control (up to 8 doors)
    • Easily programmed and maintained using Compass Windows-based downloader
    • Supports the ADEMCO 4286 VIP Module
    Additional Features

    Basic Hardwired Zones
    Provides nine style-B hardwired zones with the following characteristics:

  • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations)
  • Individually assignable to one of eight partitions
  • Up to 16 two-wire smoke detectors on zone 1
  • Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be supervised with an EOL device)
  • Up to 50 two-wire latching glassbreak detectors on zone 8
  • Polling Loop Expansion

    Supports up to 119 additional zones using a built-in polling (multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics:
  • Must use RPM (Remote Point Module) devices
  • Supervised by control panel
  • Individually assignable to one of eight partitions

    Wireless Expansion
    Supports up to 128 wireless zones using 5881 type RF receiver (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics:

  • Supervised by control panel for check-in signals (except certain non-supervised transmitters)
  • Tamper protection for supervised transmitters
  • Individually assignable to one of eight partitions
  • Scheduling

    Provides the following scheduling capabilities:
  • Open/close schedules (for control of arming/disarming and reporting)
  • Holiday schedules (allows different time windows for open/close schedules)
  • Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.)
  • Access schedules (for limiting system access to users by time)
  • End User Output Programming Mode (provides 20 timers for relay control)
  • Eight Partitions

    Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include:
  • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed and to disarm when the first partition that shares the common lobby is disarmed
  • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads)
  • All zones assignable to one of eight partitions
  • Keypads assignable to one of eight partitions or to master partition 9 to view system status
  • Ability to assign relays to one or all eight partitions
  • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions keypads (selectable option)
  • Certain system options selectable for each partition, such as entry/exit delay and subscriber account number
  • User Codes

    Accommodates 150 user codes, all of which can operate any or all partitions. Certain characteristics must be assigned to each user code, which are as follows:
  • Authority level (Master, Manager, or several other Operator levels) in each partition
  • Opening/Closing central station reporting option
  • What partitions the code can operate
  • Global arming capability (ability to arm all partitions the code has access to in one command)
  • Use of an RF (button) to arm and disarm the system (RF key must first be enrolled into the system)
  • Peripheral Devices

    Supports up to 31 peripheral devices, which can be any combination of keypads (6139/6160), RF receivers (5881), relay modules (4204/4204CF), and 4286 VIP Module.

    At least one two-line alpha keypad (6139/6160) must be connected to the system for programming (if using keypad programming) and must remain connectedto the system in order to allow the primary user to program additional usercodes into the system at a later time.

    Keypad Macros
    Accommodates 32 keypad macro commands per system (each macro is a series of keypad commands). For example, by pressing either the A, B, C, or D key, the system can be programmed to log onto another partition, bypass Zones 2 and 3,and arm that partition in the AWAY mode. Characteristics of keypad macros are:

  • Assignable to the A, B, and C keys by partition
  • Other macros, (not assigned to these keys) executed by using the D key
  • Each macro can be 32 characters (keystrokes) in length
  • Optional Output Relays

    Accommodates the use of 96 relay outputs using ADEMCOs 4204, 4204CF Relay Modules and 4101SN V-Plex Relay Module. Each 4204 module provides four Form C relays for general purpose use. Each 4204CF provides two style-Y supervised bell outputs. Relay outputs have the following characteristics:
  • Can be programmed to activate in response to system events
  • Can be programmed to activate using time intervals
  • Can be used for style-Y supervised bell outputs (4204CF only)
  • Can be activated manually using the #70 Relay Command Mode
  • Can be supervised by control panel (zones 601-632)
  • Can each have an alpha descriptor assigned to it
  • Optional VISTA Interactive Phone Module

    Supports the ADEMCO 4286 VIP Module. This permits access to the security system from a touch tone telephone to do the following:
  • Obtain system status information
  • Arm and disarm security system
  • Control relays
  • Optional Keyswitch

    Supports the ADEMCO 4146 Keyswitch on any one of the systems eight partitions. If used, zone 7 is no longer available as a protection zone.

    Voltage Triggers
    Provides a trigger connector whose pins change state for different conditions. Used with LRR (Long Range Radio) equipment or other devices such as a remote keypad sounder, keyswitch ARMED and READY LEDs, or a printer to print the systems event log.

    Event Log
    Keeps a log of different event types (enabled in programming). The event log has the following characteristics:

  • Stores up to 512 events
  • Can be viewed at the keypad or through the use of Compass software
  • Can be printed on a serial printer using a 4100SM Module including zone alpha descriptors
  • Events can be sent to an alpha numeric pager, by event category
  • Cross-Zoning Capability

    Helps prevent false alarms by preventing burglary zones from going into alarm unless its cross-zone is also faulted within five minutes.


    Exit Error False Alarm Prevention Feature

  • System can tell the difference between a regular alarm and an alarm caused by leaving an entry/exit door open. If not subsequently disarmed, faulted E/E zone (s) and/or interior zones will be bypassed and the system will arm
  • Generates an Exit Error report by user and by zone so the central station knows it was an exit alarm and who caused it
  • Communication Formats

    Supports the following formats for the primary and secondary central station receivers:
  • ADEMCO Low Speed (Standard or Expanded)
  • ADEMCO High Speed
  • ADEMCO Contact ID
  • Sescoa/Radionics
  • Long Range Radio interface (ECP)
  • ADEMCO Express
  • Improved Downloading Features

  • Uploads and downloads at 300 baud, making upload/download speed faster
  • Ability to upload peripheral devices, their physical addresses, programmed addresses, and firmware revision levels from the control
  • CCTV: Switcher Module

  • VistaView100
  • Access Control

  • VistaKey (addressable) Access Control Module
  • VistaKey-SK Starter Kit (Canada use VistaKey CNSK)
  • VistaKey-EX Expansion Kit
  • VGM Vista Gateway Module to PassPoint Access Control (Northern Computers) supports up to 32 doors
  • Agency Listings

  • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault*
  • UL611/UL1610 Grades A, AA Central Station*
  • UL365 Grades A, AA Police Connect*
  • UL985 Household Fire*
  • California State Fire Marshall (CSFM)
  • CUL Household Fire/Burglary, and also Commercial Burglary
  • UL1023 Household Burglary
  • * Requires VISTA-ULKT Attack Resistant Enclosure

    Physical: 14-1/2" W X 18" H X 4.3" D

    Electrical:
  • Voltage Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada) or 4300 transformer (for X-10 installations) rated 16.5VAC, 40 VA (For Canada use 1361CN transformer w/PSC04 for X-10 installations)
  • Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations)
  • Auxiliary Power Output: 9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range
  • Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended
  • Standby Time: 4 hours min. with 750 mA aux. load using 7 AH battery
  • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts)

    Digital Communicator:
  • Formats Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO Contact ID, Sescoa and Radionics Low Speed

    Line Seize: Double Pole

    Ringer Equivalence: 0.7B FCC Registration No.: AC398U-68192-AL-E IC Industry Canada

    6139 Remote Keypads/6160 Alpha Keypad:
  • Physical:
    - Width: 6.25 inches
    - Height 4.75 inches
    - Depth: 1.25 inches
  • Electrical:
    - Voltage Input: 12VDC
    - Current Drain: 100 mA
  • Interface Wiring:
    - RED: 12VDC input (+) auxiliary power
    - BLUE: Not used
    - GREEN: Data to control panel
    - YELLOW: Data from control panel
    - BLACK: Ground and (-) connection from supplemental power supply

    Optional Equipment:
    (See ADEMCO Group control accessories compatibility chart for complete list.)
  • 4100APG Alpha Paging
  • 7845C AlarmNet Control Channel Cellular Radio
  • 7820 Long Range Radio (7830RCN in Canada)
  • 4286 VIP Module
  • 5881 RF Receivers
  • Powerline carrier devices
  • 6220S Serial Printer
  • Ademco / Honeywell VISTA-128FBP - Commercial Fire and Partitioned Burglary Alarm Platform, supports 128 Zones/Points, 12V Model - VISTA128FBP Honeywell / Ademco VISTA-15PSIA Residential 32 Zone Control Panel with SIA Approval
    Ademco / Honeywell VISTA-128FBP - Commercial Fire and Partitioned Burglary Alarm Platform, supports 128 Zones/Points, 12V Model - VISTA128FBP Commercial Fire and Partitioned Burglary Alarm Control Panel

    Designed to integrate seamlessly with CCTV, access control, and ADEMCOs full range of fire and burglary components, the NEW VISTA-128FBP provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions, and supports up to 128 zones/points using hardwired, wireless and V-Plex addressable technologies. A diverse line of ADEMCO initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays are supported by extremely powerful control platform. The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. A revolutionary new feature called Panel Linking allows multiple partitions, panels - even buildings to be armed, disarmed and have status checked from one location.

    FEATURES
    • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones
    • Can control eight separate areas independently (8 partitions)
    • Supports Panel-Linking allows up to 8 systems or buildings to be controlled from one central location (using VA8200)
    • Supports commercial UL wireless fire and burg
    • Stores up to 512 events and can accommodate 150 user codes
    • Supports addressable V-Plex access control points using VistaKey (1 to 8 doors)
    • Supports up to 16 doors of access control using Vista Gateway Module (VGM)*
    • Supports CCTV applications with the new VistaView-100 CCTV Switcher Module
    • Identifies the point or zone of a fire or alarm, using the new FSA-8/FSA-24 Fire System Annunciator
    • Programmable to meet SIA false alarm prevention specifications. To meet UL approval forANSI/SIA CP-01-2000 order part number VISTA-128SIA
    • Two on-board notification (bell) circuits delivering 2.3 amp @ 12V or 3.4 amp @ 24V
    • Automatic smoke detector sensitivity maintenance testing
    • 4-wire smoke reset using onboard J2 output trigger
    • Supports Dynamic Signaling for LRR
    • Supports Remote Control-via the internet**
    • Supports Internet Alarm Reporting**
    • Supports the new Graphical User Interface Consoles
    • Supports up to 250 access card holders using VistaKey
    • Supports AlphaNumeric pager up to 8 different numbers using the VA8201
    * Connects to Northern Computers Passpoint Access Control Systems. Maximum 32 doors.

    ** When used with AlarmNet-i

    ADDITIONAL FEATURES

    • Notification Appliance Circuits (two):
      - Programmable
      - Temporal code compliant
      - Individually silenceable
    • Programmable on-board auxiliary relay
    • SIA false alarm reduction features:
      - Exit error logic
      - Exit delay reset
      - Cross zoning
      - Call waiting defeat
      - Recent close report
    • Supports commercial hardwired, addressable V-Plex polling loop and wireless zones
    • Hardwired zones
      - Provides eight style B hardwired zones
      - EOLR supervised for Fire and UL burglary installations
      - Supports N.O or N.C. sensors
      - Individually assignable to any eight partition
      - Up to 32 two-wire smoke detectors each on zone one and two (64 total)
      - Up to 50 two-wire glassbreak detectors on zone eight
    • Patented addressable V-Plex polling loop technology
      - Supports 120 two-wire zones points
      - Global polling technology for faster processing
      - Increased current draw capacity (128mA)
      - Supervised by panel
      - Individually assignable to partitions, notification circuit (bell) output or aux relay
      - 4,000 ft capability without the use of shielded cable
      - Extender/Isolation bus module
      - Two-wire smoke detector zone/group expansion module adds two or four zones
      - Eight zone - Class A and B extender module
      - Eight zone - Class B extender module
      - One zone supervised contact monitor module
    • UL Listed wireless expansion
      - Supports up to 128 wireless zones/points using 5881ENHC receiver
      - Supervised by control for check-in signals
      - Tamper protection for transmitters
      - Individually assignable up to eight partitions
      - Supports UL864/NFPA approved wireless smoke detectors
    • Access Control integration
      - Full integration with PassPoint Access Control System Complete Gateway interface of VISTA and access functions
    • Up to 8 doors using VistaKey V-Plex Access Control
    • Event reporting
    • Local printer of access or VISTA related event
    • Scheduled uploading of events to central station
    • Stored events for one call retrieval
    • Communication 
      - Phone mapping by zone response type
      - Supports VIP interactive phone voice module
      - Panel operation during download
      - Uploading equipment list to central station
      - Communication to PassPoint via Vista Gateway Module
    • CCTV integration
      - Supports VistaView-100 ECP based CCTV switchers
    APPLICATIONS
    The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments.


    Installation
    The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations.

    CONTROL PANEL SPECIFICATIONS:

    Applications:
    The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments.

    Installation: The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations.

    Electrical Specifications :
  • Primary power: 18VAC @ 72VA Honeywell No. 1451
  • Control panel quiescent current draw: 350mA
  • Backup battery:
    12VDC, 12AH min to 34.4AH max
    Lead acid battery (gel type)
  • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3amps @ 12V
  • Aux. standby pwr: 12VDC, 1Amax
  • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources
  • Standby time: 24 hours with 1A standby load using 34.4AH battery
  • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited.
  • Optional 24-volt power supply, PS 24 Supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputsMain Dialer:
  • Line seize: Double Pole
  • Ringer equiv.: 0.7B
  • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics
  • Dual phone line capability (using 5140DLM module)

    Cabinet dimensions:
  • 18H X 14.5W X 4.3D

    Environmental:
  • Storage temp: 14F to 158F (-10C to 70C)
  • Operating temp: 32F to 122F (0C to 50C)
  • Humidity: 85% RH
  • EMI: Meets or exceeds the following requirements:
    FCC Part 15, Class B Device
    FCC Part 68
    IEC EMC Directive

    Agency Listings Burglary:
  • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault
  • UL611/1610 Grades A, AA, Central Station
  • UL365 Grades A, AA Police Connect

    Fire:
  • UL864/NFPA72 Local, Central Station and Remote Station
  • Factory Mutual
  • California State Fire Marshal
  • MEA
  • UL985

    Auxiliary Devices:
  • 6160CR
    Red Alpha Keypad
  • 6139R
    Red Alpha Keypad/Annunciator
  • FSA-8 & FSA-24 annunciator modules
  • 4204
    Relay Module, four form C contacts
  • 4204CF
    Two supervised output circuits
  • 5881 Series
    RF receiver supporting 5800 wireless detectors
  • 6220S
    System printer used with 4100SM serial module

    Two-wire smoke detectors, conventional:
  • 2100 Series Photoelectric
  • 2400 Series Photoelectric
  • 1100 Series Ionization

    Four-wire smoke detectors, conventional:
  • 2112/24 Series Photoelectric
  • 1412 Series Ionization

    Horn/Strobes:
  • System Sensor Notification Appliances

    Manual Pull Stations:
  • 5140MPS-1
  • 5140MPS-2

    V-Plex (addressable) Devices:
  • 4208U Loop Expansion Module
    eight zones
  • 4101SN Single Relay/Zone Module
  • 4208SNF Class A/B Expander Module
  • 4209U Group Zoning Module
    two/four zones
  • 4190SN Remote Point Module
    two zones
  • 4193SN Two Zone Serial Interface Module
  • 4293SN One Zone Serial Interface Module
  • 4297 Isolation/Extender Module

    V-Plex (addressable) Smoke Detectors:
  • 5192SD
  • 4192SD
  • 4192CP
  • 5192SDT
  • 4192SDT
  • 4192CPM
  • 4192SDTM

    V-Plex Passive Infrared Detectors:
  • 998MX
  • 4275EX-SN
  • 4278EX-SN

    V-Plex (addressable) Contacts:
  • 4939SN-WH
  • 4944SN-WH
  • 4959SN

    V-Plex Glassbreak Detectors:
  • 9500SN

    VISTA interactive phone module:
  • 4286 Voice Module

    Optional 24V Power Supply:
  • PS24
    24V power supply
    3.4A

    Long Range Radio:
  • Long Range Radio 7720ULF-XX, 7835C, 7835CF, 7845C

    Upgraded software:
  • Upgraded Compass Downloader Windows compatible

    Wireless Devices:
  • 5804BDV
    Bi-directional with voice
  • 5804BD
    Bi-directional Key
  • 5804Watch
    Wireless Key & sports watch combined
  • 5816
    Door/Window Transmitter
  • 5804
    Wireless key
  • 5827BD
    Bi-directional Keypad
  • 5890
    PIR
  • 5849
    Glassbreak Detector
  • 5819
    Shock Sensor

    Commercial Wireless Devices:
  • 5808W3
    Photoelectric Smoke/Heat Detector
  • 5809
    Wireless Heat Detector
  • 5817CB
    Wireless Commercial Transmitter
  • 5869
    Hold-Up Transmitter
  • 5881ENHC
    Commercial Fire/Burg Receiver Access Control
  • VistaKey V-Plex (addressable)

    Access Control:
  • VistaKey-SK Starter Kit
  • VistaKey-EX Expansion Kit
  • VGM Vista Gateway Module to PassPoint Access Control (Northern Computers)

    CCTV:
  • VistaView-100 CCTV Switcher or Module

    Alarm Communications:
  • Graphical user interface with Internet capability
  • Internet Remote Control-Networking Module
  • Internet Alarm Communicator (7845i)
  • 7845GSM
    Digital Cellular Communicator
  • 7845i-GSM
    Internet and Digital Cellular Communicator

    Paging:
  • VA8201 AlphaNumeric Pager

  • All the same features as the VISTA-15P
    UL Approval for ANSI/SIA CP-01-2000

    The versatile VISTA-15P is the ideal choice for any residential installation. Hardwired expansion, graphic keypad support, two-wire smoke detectors, scheduling options and a host of end-user and installer features separate the VISTA-15P from all other six-zone panels offering you and your customers the most panel for the dollar.

    Features

    • Six on-board hardwired zones
      - 16 hardwired expansion zones totaling 22
      - 26 wireless expansion zones
    • Supports 6270 and 8132 traphic touchscreen keypads
    • Eight independent keyfob zones allow wireless keys to be programmed without using any of the 26 zones
    • Eight output devices
      - Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or
      - X-10 devices (when used with a1361X10 Transformer)
    • Two low current on-board trigger outputs
    • 50 Event Log viewable at system keypads with time/date stamp
    • 32 system user codes
    • Two installer configurable zone types allows the installer to "create custom zone types" by assigning all zone attributes
    • Multiple actions on output devices depending on system "state"
      - Turns light off when system arms
      - Turns same lights on when system disarms
      - Flashes same lights when system is in alarm
    • Built-in phone line cut monitor with programmable delay and annunciation options
      - Display on system keypads
      - Trigger local sounders
      - Trigger system bell
    • Supports four-wire, and up to 16 two-wire smokes
      - Works with Sentrol CleanMeTM maintenance signal
    Valuable End-User Features
    • Now viewable on system keypads:
      - Exit countdown
      - Time and date display*
      - Event log*
    • Auto keypad backlighting on entry
    • Keyswitch arming
    • Programmable macro buttons and single-button arming
    • A variety of wireless remote controls for single-button operation
    • User Scheduling
      - Automatically activates X-10 and relays at programmed times
      - Latchkey reports to pagers
      - Auto arm/disarm
      - "User access" time windows
    • Supports up to two numeric pagers
    • VIP Module allows system control from any touchtone phone
    • Chime by zone
    *Requires custom alpha keypad

    Security Dealer Features

    • Automatic System Load Shed
      - During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries
    • Dynamic Signaling
      - Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet Radio
    VISTA-15P Control Panel 781410414846
    Ademco / Honeywell VISTA-20P - Vista Plus Series Control Panel only - VISTA20P Honeywell / Ademco VISTA-20PSIA Residential 48 Zone Control Panel with SIA Approval

    Ademco / Honeywell VISTA-20P - Vista Plus Series Control Panel only - VISTA20P


    Our Price : $123.04

    Sale Price: $82.50
    You save $40.54!
    The high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection, graphic keypad support and dual partitions. The panel's installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations.

    VISTA-20PSIA Residential 48 Zone Control Panel with SIA Approval
    • All the same features as the VISTA-20P
    • UL approval for ANSI/SIA CP-01-2000
    Ademco / Honeywell VISTA-250BP - Commercial Burglary/CCTV and Access Control Platform - VISTA250BP Ademco / Honeywell VISTA-40 Universal Control Panel - VISTA40

    The VISTA-250BP is an eight partition, eight to 250 zone UL listed commercial burglary control panel that meets the demanding requirements for today’s medium-sized commercial installations while simplifying the end-user operation.

    The VISTA-250BP is ideal for locations like large office complexes, medical clinics, bank branches, medium-to-largesized distribution centers, warehouses, auditoriums, school campuses and other large public buildings.

    This panel provides system scalability and utilizes conventional V-Plex and wireless zone expansion. The VistaKey access control system, Vistaview-100 and Optiflex allow seamless integration with this powerful commercial platform. The VISTA Navigator Controller/Reporter allows on-site remote work station system operation and management. The VISTA-250BP interfaces with AlarmNet GSM/iGSM Communicators even without POTS lines.

    Features

    • Provides nine on-board style-B hardwired zones
    • Supports up to 241 additional zones using a built-in polling (multiplex) loop interface
    • Supports up to 250 wireless zones using 5881 type RF receiver (fewer if using hardwired and/or polling loop zones)
    • Provides 1 power-limited bell circuit delivering 1.7Amp (max) at 12Vdc
    • Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control
    • Accommodates 250 user codes with seven authority levels per partition
    • Accommodates 32 keypad macro commands per system
    • Keeps a log of up to 1,000 events
    • VISTAView-100 CCTV support
    • Supports up to 16 two-wire smoke detectors on zone 1
    • Supports up to 50 latching-type glassbreak detectors on zone 8
    • Zone 7 may be used for keyswitch arming/disarming
    • Integrates with WIN-PAK access control systems to provide increased users, event log and scheduling
    • Supports V-Plex addressable VISTAKey access control (up to 15 doors and 500 cards)
    • Easily programmed and maintained by the newly upgraded Compass Windows-based downloader
    • Supports up to 96 programmable relays
    • Supports the ADEMCO 4286 VIP Module
    • Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP- 01-2000 order part number VISTA- 128SIA

    New Enhancements:

    • Upload/Download using AlarmNet devices
    • CO detector support
    • Two-way RS232 (facility automation software support) optional
    • Supports eight numeric pager numbers
    • Supports touchscreen Advanced User Interface (AUI)
    • Smoke Detector Reset at keypad
    • Panel linking up to eight panels
    • Quick Exit
    • Group Bypass
    • Arm Faulted
    • Event Arming
    • Scheduled check-in
    • Arm Stay by group

    Additional Features

    Additional Features Basic Hardwired Zones

    • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations)
    • Individually assignable to one of 8 partitions
    • Up to 16 two-wire smoke detectors on zone 1
    • Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be supervised with an EOL device). Listed for residential fire only.
    • Up to 50 two-wire latching glassbreak detectors on zone 8

    Polling Loop Expansion
    Supports up to 241 additional zones using a built-in polling (multiplex) loop interface. Polling loop zones have the following characteristics:

    • Must use RPM (Remote Point Module) devices
    • Supervised by control panel
    • Individually assignable to one of 8 partitions
    • Supports VSI module operation
    • Supports 4297 Expander Module
    • Maximum wiring distance - 12, 000 feet

    Wireless Expansion
    Supports up to 250 wireless zones using 5881 type RF receiver (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics:

  • Supervised by control panel for check-in signals (except certain nonsupervised transmitters)
  • Tamper protection for supervised transmitters
  • Individually assignable to one of eight partitions
  • Scheduling
    Provides the following scheduling capabilities:

  • Open/Close Schedules (for control of arming/disarming and reporting)
  • Holiday Schedules (allows different time windows for open/close schedules)
  • Timed Events (for activation of relays, auto-bypassing and unbypassing, autoarming and disarming, etc.)
  • Access Schedules (for limiting system access to users by time)
  • Eight Partitions
    Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include:

  • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed
  • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads)
  • All zones assignable to one of eight partitions
  • Keypads assignable to one of eight partitions or to Master partition 9 to view system status
  • Ability to assign relays to one or all eight partitions
  • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option)
  • Certain system options selectable for each partition, such as entry/exit delay and subscriber account number
  • New Enhancement: Panel Linking.
    Panel Linking allows multiple control panels to be networked together and controlled from any keypad in the system:
  • Control multiple zones, partitions, buildings from a central location
  • Check status, arm and disarm any partition from any keypad in the system (based on user’s authority level)
  • Users can have a different authority level in each partition and access to different partitions in each panel
  • Global Arming - users can arm and disarm all the partitions in all the panels they have access to, with one set of keystrokes

    Applications:
    The VISTA-250BP control is well suited for a variety of applications as a burglary control. A diverse line of ADEMCO initiating devices support this extremely powerful control. Some of the applications supported are medical and professional buildings, supermarkets, churches or synagogues, office buildings, schools, universities, strip malls, larger residences and factory or warehouse environments.

    Installation:
    The VISTA-250BP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for ULCommercial Burglary installations, use the VISTA-ULKT kit when an attack resistant enclosure is required.

    Agency Listings (all future), Burglary:
  • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault
  • UL611/UL1610 Grades A, AA Central Station
  • UL365 Grades A, AA Police Connect
  • UL985 Household Fire
  • UL1635 - Digital Alarm Communicator System Units
  • UL1023 Household Burglar Alarm
  • California State Fire Marshall (CSFM)
  • CAN/ULC - S303
  • CAN/ULC - S304
  • CAN/ULC - S545
  • CAN/ULC - S1023

    Specifications—Electrical:
  • Voltage Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada) or 4300 transformer (for X- 10 installations) rated 16.5VAC, 40 VA
  • Alarm Sounder Output:10VDC- 13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations)
  • Auxiliary Power Output: 9.6VDC- 13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range
  • Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended
  • Standby Time: 4 hours min. with 750 mA aux. load using 7 AH battery
  • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts).

    Main Dialer:
  • Formats Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO Contact ID, Sescoa and Radionics Low Speed
  • Line Seize: Double Pole
  • Ringer Equivalence: 0.7B

    Cabinet dimensions:
  • 12-1/2" W X 14 1/2" H X 3" D

    Auxiliary Devices:
  • 4204 – Relay Module, four form C contacts
  • 4204CF – two supervised output circuits
  • 5881 Series – RF Receiver supporting 5800 wireless detectors
  • 6160/6139 – Alpha Keypad/Annunciator
  • 6220S – System Printer used with 4100SM serial module
  • VA8200 – (PLM) Panel Linking Module
  • VA8201 – (APM) Alpha Paging Module

    Two-wire smoke detectors: conventional
  • System Sensor smoke detectors

    Horn/Strobes:
  • System Sensor Notification Appliances

    Manual pull stations:
  • 5140MPS-1
  • 5140MPS-2

    V-Plex (addressable) devices:
  • 4101SN Single Relay/Zone Module
  • 4190SN Remote Point Module – two zones
  • 4193SN Two Zone Serial Interface Module
  • 4208U Loop Expansion Module – eight zones
  • 4208SNF Class A/B Expander Module
  • 4209U Group Zoning Module – two/four zones
  • VSI Module
  • 4293SN One Zone Serial Interface Module
  • 4297 Isolation/Extender Module VPlex (addressable) smoke detectors
  • 5192SD
  • 5192SDT

    Passive infrared detectors:
  • 998MX
  • 4275EX-SN
  • 4278EX-SN
  • QUEST2260SN

    V-Plex (addressable) contacts:
  • 4939SN-WH
  • 4944SN-WH
  • 4959SN, 9500SN

    V-Plex Glassbreak detectors:
  • FG1625SN

    VISTA interactive phone module:
  • 4286 Voice Module

    Long range radio:
  • Long Range Radio 7845GSM, 7845iGSM, 7845i

    Upgraded software:
  • Upgraded Compass Downloader Windows compatible

    Wireless devices:
  • 5804 – Wireless Key
  • 5804BD – Bi-directional Key
  • 5804BDV – Bi-directional with voice
  • 5816 – Door/Window Transmitter
  • 5819 – Shock Sensor
  • 5827BD – Bi-directional Keypad
  • 5849 – Glassbreak Detector
  • 5890PI – PIR

    Access control:
  • VISTAKey V-Plex (addressable) Access Control
  • VISTAKey-SK Starter Kit
  • VISTAKey-EX Expansion Kit
  • VGM VISTA Gateway Module to PassPoint Access Control (Northern Computers)

    CCTV:
  • CCTV – VISTAView-100 CCTV Switcher Module

    Commercial Wireless Devices:
  • 5808W3 – Wireless Smoke Detector**
  • 5809 – Wireless Heat Detector
  • 5817CB – Commercial UL Burglary, Universal Contact Monitoring Transmitter*
  • 5869 – Commercial UL Wireless Hold-up Button*
  • 5881ENHC

    * When used with 5881ENHC receiver.
    ** Not listed for commercial use with VISTA-250BP, residential listing only.
  • Enhanced version of the 4140XMP

    The feature-rich VISTA-40 Control Panel is a cost-effective solution for almost any application. Features include advanced partitioning, end-user simplicity and compatibility with the best wireless technology today.

    A powerful control, the VISTA-40 can support residential installations and operate lights and appliances - providing you with greater installation flexibility  while offering your customers the ultimate in convenience.

    Dependable features to meet your most demanding installations

    • Nine hardwired zones, expandable to 64 zones
    • Two partitions with seven authority levels
    • 70 user codes
    • 100 event alarm history log
    • Two-way downloading
    • Supports 16 two-wire smoke detectors and 16 keypads
    • Three technology options:
      - Standard hardwired, expander 4208U (8 zones) 4190WH (2 zones)
      - ADEMCO polling loop addressable devices
      - Wireless (5800 series)
    • Supports up to eight relays
    • Supports X-10 transformer (Part No. 4300)
    • Long Range Radio triggers (four)
    End users will appreciate the easy-to-use convenience and control features of the VISTA-40
    • Wireless remote controls (featuring single button system operation):
      - 5804 - Four button programmable wireless key
      - 5804BD - Bi-directional four-button programmable wireless key with system status feedback
    • Single or dual-button wireless personal panic:
      - 5802MN
      - 5802MN2
    • Home automation activates lights, appliances, garage doors, and numerous other devices
    • The Vista Interactive Phone Module (VIP) gives the end-user control of the system from any touchtone phone; the 4286 VIP responds in clear English, with over a 100 word vocabulary
    • Full English display keypads clearly communicate system status and zone locations

    Electrical Specifications:
  • Aux power 12VDC, 750 max.
  • 16.5VAC/40 VA transformer
  • Alarm output 12VDC, 1.7 amps max
  • For UL installations, combined Aux and alarm output cannot exceed 750mA

    EOutput Control:
  • Supports up to two relay boards (Part No. 4204)
  • Each relay board supports four relays for a total of eight
  • Optional X-10 transformer/interface (part number 4300) may be used to control X-10 receiving devices

    Zones:
  • Nine hardwired zones
  • Selectable response on zone 9: 10msec or 500msec
  • Assignable to either partition
  • 14 zone types to choose from
  • Programmable swinger suppression
  • Expandable to 64 zones using 5800 wireless, or hardwired expansion

    Communications:
  • Touchtone or pulse
  • Formats supported: ADEMCO Contact ID, ADEMCO 4 + 2 Express, ADEMCO low speed
  • 3+1, 4+1 and 4+2 reporting
  • Reporting capabilities: Split, Dual, Split/Dual
  • Low battery reports 11.2-11.6VDC
  • Expanded reporting
  • Up to four digit PABX code supported
  • True dial tone detection
  • Double pole line seizure
  • AC loss and restoral reporting supported

    SUPPORTED DEVICES

    Hardwired Expansion Devices:
  • 4208U up to eight zones - 25 mA
  • 4204 up to eight relays - 15mA (each active relay draws 40mA)
  • Powerline support - 4300 transformer/interface
  • Keypads
    6139 custom English (required for programming) - 100mA
    6128 fixed English LCD - 30mA
  • Voice Module 4286VIP - 160mA
  • Two-wire smoke detectors
  • V-Plex polling loop devices and keyswitch devices

    Wireless Receiver Systems:
  • 5800 Receivers
    5881ENL up to 8 zones - 50mA
    5881ENM up to 16 zones - 50mA
    5881ENH up to 64 zones - 50mA
  • All receivers support:
    Diversity reception with two antennas
    Remote mounting for best location
    A second receiver for maximum coverage or tough installations
    Unique supervision and low battery indications by point

    Transmitters:
  • 5800 Series - three volt lithium batteries, one mile range, tamper standard

    Agency Listings:
  • UL Residential Fire and Burglary and CFM
  • Commercial Burglary (with VISTA-UL kit)
  •    
     