AL1012ULACM

Power Supply/Charger w/Multi
-Output Access Power Controller

Overview

Model AL1012ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC non power limited fuse protected Fail
-Safe and/or Fail
-Secure outputs with a total of 10 amp continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL1012ULACMCB is a PTC protected version of this unit.

Agency Listings


UL Listed for Access Control Systems (UL294), CUL Listed
- CSA Standard C22.2 No.205
-M1983, Signal Equipment. File# BP6714.

Features/Specifications

Power Supply/Charger:
12VDC output.
10 amp of continuous supply current.
115VAC 60Hz, 1.9 amp input.
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.
Built
-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .7 amp.
Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty.

Access Power Controller:


Eight (8) Access Control System outputs.
- Eight (8) fuse protected Fail
-Safe and/or Fail
-Secure 12VDC or 24VDC power outputs.
- Any power output may be converted to dry form "C" relay output.
- Eight (8) fuse protected 12VDC auxiliary power outputs (unswitched).
Red LEDs indicate outputs are triggered (relays energized).
Eight (8) Access Control System trigger inputs.
- Eight (8) normally open (NO) inputs.
- Eight (8) open collector inputs.
- Any combination of the above.
Fire Alarm Disconnect:
- Fire Alarm Disconnect (latching or non
-latching) is individually selectable for any or all of the eight (8) outputs.
- Normally open (NO) or normally closed (NC) dry contact input.
- Polarity reversal input FACP signaling circuit.
Fire Alarm trigger LED indicates that the Fire Alarm Disconnect has been activated.
Fire Alarm output relay for triggering auxiliary reporting devices (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty.

Enclosure


Accommodates up to two (2) 12VDC/12AH batteries.
Dimensions: 15.5H x 12W x 4.5D.
1/2" and 3/4" combination knockouts.