My Account
|
View Cart
|
Contact Us
Shop Brands
Shop Products
Specials
Access Control
Audio / Video
Burglar Alarms / Intrusion
CCTV / Surveillance
Fire Alarms
Gadgets & Electronics
Home Automation
Locks
Networking / IP
Phones & Intercoms
Tools & Hardware
Wire & Cable
Glow in the Dark Exit Signs
Gold Plus Tester
GPS Vehicle Tracking Devices
Honeywell IP Cameras
imogen +CAM Wireless Network CAM iPhone & Android
Mohawk Cable
Suprema Biometrics
Home
>
Shop Brands
>
Altronix
>
Fire
>
Altronix AL802ULADAJ - NAC Power Extender. 12/24VDC @ 8A. Class 2.. Lrg Encl.
Our Price :
$327.56
UPC Code:
782239936854
Product Code:
539692
Qty:
Description
AL802ULADAJ
NAC Power Extender
Overview
Model AL802ULADAJ is an extremely cost effective 8 amp voltage regulated remote power supply/battery charger. It may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories. The unit delivers regulated and filtered 24 or 12 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.0A auxiliary output with reset for four (4)-wire smoke detectors is available. The 8 amp rated supply current can be divided between the four (4) outputs for powering NAC devices. Each output is rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also features “Loop Output” trouble memory indication to help identify troublesome sporatic problems. Model is available in a smaller enclosure AL802ULADA.
Agency Listings
• UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL1481). File# S5075.
• CSFM - California State Fire Marshal Approved. File# 7315-1335:107.
• MEA - NYC Department of Buildings Approved.
• FM Approved.
Features/Specifications
Power Supply/Charger:
• 12VDC or 24VDC selectable output.
• 8 amp max total alarm current.
• 115VAC 60Hz., 1.45 amp.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
• Lifetime Warranty.
Logic Board:
• Class 2 Rated power limited outputs.
• Two (2) Class A or two (2) Class B FACP inputs.
• Two (2) NC dry contact trigger inputs.
• Two (2) Class A or four (4) Class B Indicating Circuits.
• Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
• One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
• Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs.
• 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
• Horn/Strobe sync protocols include: Gentex, System Sensor, Faraday, Amseco.
• Temporal Code 3 Mode.
• Steady Mode.
• Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
• March Time.
• Compatible with 24VDC or 12VDC fire panels.
• Common Trouble inputs and outputs.
• Ground fault detection.
• Lifetime Warranty.
Enclosure
• Accommodates up to four (4) 12VDC/12AH batteries.
• Dimensions: 18”H x 14.5”W x 4.625”D.
• 1/2" and 3/4" combination knockouts.
You may also be interested in...
Altronix AL600ULB8 - POWER SUPPLY BOARD FOR THE AL
Our Price :
$153.31
Add
Altronix AL600LGK - AL600 ENHANCED ALOGIC BOARD
Our Price :
$156.83
Add
Altronix AL1024ULXPD8CB - 8 PTC Outputs Power Supp
Our Price :
$351.03
Add
Altronix AL600ULXPD4 - AL600ULX W/PD4 INSTALLED 12
Our Price :
$312.72
Add
Altronix AL600ULPD4CB - 4 PTC Outputs Power Supply
Our Price :
$273.68
Add
Browse for more products in the same category as this item:
Shop Brands
>
Altronix
>
Fire
Shop Brands
>
Altronix
CCTV & Video Surveillance ->
Advanced Technology Video - ATV
AG Neovo displays
American Dynamics
APPro Technology Inc.
Bolide
DiGiMERGE
Digital Watchdog
Eastern CCTV
GeoVision
Honeywell Ademco Video
IC RealTime
Ikegami
LTS CCTV
Access Control & Biometrics Systems ->
Accutech
AWID Applied Wireless Identifications
Actuator / Bioaxiss
BioScrypt
GeoVision Access Control
Honeywell Access Control
IEI
Nedap Long Distance Vehicle ID System
RoamAlert Wander Prevention
Watchmate Wander Prevention