AL1012ULACMCB Power Supply/Charger w/Multi-Output Access Power Controller Overview Model AL1012ULACMCB converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC Class 2 Rated power limited PTC protected Fail-Safe and/or Fail-Secure outputs with a total of 10 amp continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL1012ULACM is a fuse protected version of this unit. Agency Listings • UL Listed for Access Control Systems (UL294), CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment. File# BP6714. Features/Specifications Power Supply/Charger: • 12VDC output. • 10 amp of continuous supply current. • Class 2 Rated power limited output. • 115VAC 60Hz, 1.9 amp input. • Filtered and electronically regulated outputs. • Short circuit and thermal overload protection. • Built-in charger for sealed lead acid or gel type battery backup. • Maximum charge current .7 amp. • Zero voltage drop upon transfer to battery backup. • AC input and DC output LED indicators. • AC fail supervision (form "C" contact rated @ 1 amp 28VDC). • Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC). • Lifetime Warranty. Access Power Controller: • Eight (8) Access Control System outputs. - Eight (8) PTC protected Fail-Safe and/or Fail-Secure 12VDC or 24VDC power outputs. - Any power output may be converted to dry form "C" relay output. - Eight (8) PTC protected 12VDC auxiliary power outputs (unswitched). • Red LEDs indicate outputs are triggered (relays energized). • Eight (8) Access Control System trigger inputs. - Eight (8) normally open (NO) inputs. - Eight (8) open collector inputs. - Any combination of the above. • Fire Alarm Disconnect: - Fire Alarm Disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs. - Normally open (NO) or normally closed (NC) dry contact input. - Polarity reversal input FACP signaling circuit. • Fire Alarm trigger LED indicates that the Fire Alarm Disconnect has been activated. • Fire Alarm output relay for triggering auxiliary reporting devices (form "C" contact rated @ 1 amp 28VDC). • Lifetime Warranty. Enclosure • Accommodates up to two (2) 12VDC/12AH batteries. • Dimensions: 15.5”H x 12”W x 4.5”D. • 1/2" and 3/4" combination knockouts.
|
AL1012ULXPD16CB Power Supply/Charger Overview Model AL1012ULXPD16CB power supply converts a 115VAC 60Hz input, to 8 amp of continuous supply current, 10 amp during alarm @ 12VDC distributed via sixteen (16) PTC protected Class 2 Rated outputs. Model AL1012ULXPD16 is a fuse protected version of this unit. Agency Listings • UL Listed for Access Control Systems (UL294), CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment File # S4707. • NFPA 72 Compliant. Features/Specifications • 12VDC output. • 10 amp of continuous supply current. • Class 2 Rated power limited outputs. • Sixteen (16) PTC protected outputs. • 115VAC 60Hz, 1.9 amp input. • PTCs are rated @ 2.5 amp • Filtered and electronically regulated outputs. • Short circuit and thermal overload protection. • Built-in charger for sealed lead acid or gel type battery backup. • Maximum charge current .7 amp. • Zero voltage drop upon transfer to battery backup. • AC input and DC output LED indicators. • AC fail supervision (form "C" contact rated @ 1 amp 28VDC). • Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC). • Lifetime Warranty. Enclosure • Accommodates up to two (2) 12VDC/12AH batteries. • Dimensions: 15.5”H x 12 ”W x 4.5”D • 1/2 and 3/4 combination knockouts.
|
|
|
|
|
|
|
|
|
|
|
SMP10PM12P16CB Multi-Output Supervised Power Supply/Charger Overview Model SMP10PM12P16CB power supply converts a 115VAC 50/60Hz input, to a 12VDC @ 10 amp of continuous supply current distributed via sixteen (16) PTC protected outputs. Features/Specifications • 12VDC output. • 10 amp of continuous supply current output. • Sixteen (16) PTC protected outputs. • PTCs are rated @ 2.5 amp. • 115VAC 50/60Hz, 1.45 amp input. • Filtered and electronically regulated outputs. • Short circuit and thermal overload protection. • Built-in charger for sealed lead acid or gel type battery backup. • Maximum charge current .7 amp. • Zero voltage drop upon transfer to battery backup. • AC input and DC output LED indicators. • AC fail supervision (form "C" contact rated @ 1 amp 28VDC). • Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC). • Lifetime Warranty. Enclosure • Accommodates up to two (2) 12VDC/7AH batteries. • Dimensions: 13.5”H x 13”W x 3.25”D. • 1/2" and 3/4" combination knockouts.
|
Altronix 1224DCF - POWR SUPPLY 12 OR 24 VOLTS 8 OUTPUTS 4 AMP. 05/07/07 REPLACES 1224DCFID
|
|
|
|
|
|
|
|
|
|
|
Altronix 164175 - POWER SUPPLY 16VAC 4 FUSED OUTPUTS 11 AMP. 11 AMPS
|
Altronix 400ULXFID - OLD STYLE AL400ULX. METAL CANADA CLASS. 9403.20.0070
|
|
|
|
|
|
|
|
|
|
|
Altronix 400ULXPD4 - 12/24 VDC UL P/S W/4FUSED OTPT.
|
Altronix 400UXP16F - AL400ULX WITH ALTERNATE TRANSFORMER AND PD16. 12/23/05 REPLACES AX-400UXP82F
|
|
|
|
|
|
|
|
|
|
|
Altronix 600UXP8F - AL600ULXPD8 OLD VERSION WITH TRANSFORMER. 10/11/06 REPLACES AX-600XP8CF
|
6030 Multi-Purpose Timer Module Mandated Daylight Saving Time Change. All updated models have a yellow dot on the packaging. Microchips to upgrade timers in the field or inventory are available at your distributor. For more information please contact Altronix at info@altronix.com or call us at 888-258-7669, or refer to the Contact page. Overview The 6030 programmable timer is suitable for most functions that require a timed operation e.g. Applications, Siren/Bell Cut Off Module, Dialer Delay, Guard Tour Supervisory Timer, Pulser / Flasher, etc. Features/Specifications • 6VDC or 12VDC selectable operation. • Quick and extremely accurate time range adjustment from 1 second to 60 minutes. • LED indicates relay is energized. • Form "C" relay contacts are 5 amp at 120VAC/28VDC. • Current draw stand by 3mA relay energizes at 75mA. • Repeat (flasher/pulse) mode. • Relay activates at the end of the timing cycle. • Lifetime Warranty. Board • Dimensions (approximate): 2.5”W x 3”L x 0.75”H.
|
|
|
|
|
|
|
|
|
|
|
6062 Multi-Purpose Timer Module Mandated Daylight Saving Time Change. All updated models have a yellow dot on the packaging. Microchips to upgrade timers in the field or inventory are available at your distributor. For more information please contact Altronix at info@altronix.com or call us at 888-258-7669, or refer to the Contact page. Overview Model 6062 programmable timer is suitable for many functions that require a timed operation e.g. Access Control Applications, Siren/Bell Cut Off Module, Dialer Delay, Guard Tour Supervisory Timer, etc. Some optional functions include: One Shot, Delayed Release, Delayed Operate, Delayed Pulse and Pulser/Flasher. A new feature has been added which provides a momentary relay activation at the end of a desired timing cycle. This feature eliminates the need for having to use two (2) timers to achieve this function.Another new feature will cancel (interrupt) timing cycle and reset timer if desired. Features/Specifications • 12VDC or 24VDC selectable operation. • Quick and extremely accurate time range adjustment from 1 sec. to 60 min. • LED indicates relay is energized. • Form "C" relay contacts are 8 AMP at 120VAC/28VDC. • Current Draw: Stand-by 3mA, Relay Energized 40mA. • Triggers via positive DC (+) voltage, dry contact closure, or removal of contact closure. • Selectable relay activation at the start or end of the timing cycle. • One (1) second momentary relay activation at the end of the timing cycle (eliminates the need to use two (2) timers for this function). • Built-in reset feature which cancels timing cycle. • Repeat (pulser/flasher) mode. • Snap Trac compatible (order Altronix model# ST3) • DIN Rail Mount version available (order Altronix model# DTMR1). • Lifetime Warranty. Board • Dimensions (approximate): 2.5”W x 3”L x 0.75”H.
|
Altronix 606212HR - 6062 WITH MODIFIED 12 HOUR.
|
|