The American Dynamics ADAC422D RS-422 Distribution Panel
amplifies an RS-422 communications signal to provide multi-point dome
control. This allows the flexibility to operate efficiently in
protocol-setting. Home-run wiring and multiple daisy-chained links can
be fitted to SpeedDome programmable dome cameras or J-Boxes, using the
16 panel outputs of this panel. The distribution panel is
well-suited with Intellex Digital Video Management Systems and
MegaPower Matrix Switcher/Controller systems. Including inputs for
multiple MegaPower CPUs, the RS-422 distribution panel allows
maintaining control from both the primary and backup CPUs, thereby
providing a redundant solution. Mounting the 2U designed panel
on a wall or even at the front/rear of an electronic rack is
practically effortless. It is easy to install the RS-422 distribution
panel. The panel can either be installed at the head end or even at
remote locations. When power is available for domes locally, the panel
can be used in place of a 422 J-Box.
-
Able to amplify RS-422 communications signals for multi-point dome control
-
Accommodation of home-run dome wiring via 16 output ports
-
Supports home-run, daisy-chain, star, and junction box (J-Box) wiring topologies to accommodate any type or size system
-
Compatible with American Dynamics MegaPower matrix switcher/controller
systems, Intellex digital video management systems, and RS-422
converter (RCSN422)
-
Rack (2U) or wall mountable
-
Space-saving design allows mounting at either the front or rear of an electronics rack, facing in or out
-
Install at head end or remote locations
-
Surge suppression provided on all data and power connections
- USB Specifications
- Bit Rate . . . . . . . . . . . . . . . . . . . . . . .1.5 Mb/s Low Speed, 12 Mb/s Full Speed
- Maximum Cable Length . . . . . . . .3 m (9.8 ft) for 1.5 Mb/s, 5 m (16.4 ft) for 12 Mb/s
- Specification . . . . . . . . . . . . . . . . . . .Universal Serial Bus USB Specification Revision 1.1
- Connector . . . . . . . . . . . . . . . . . . . . .USB Type B receptacle
- Power Source . . . . . . . . . . . . . . . . . .5.0 VDC +/- 5%, 0.75 W from USB host controller port (power adapter not required)
- SensorNet Specifications
- Address Range . . . . . . . . . . . . . . . . .1 to 254 (configurable)
- Bit Rate . . . . . . . . . . . . . . . . . . . . . . .230.4 Kbps
- Network Distance . . . . . . . . . . . . . .1 km per node
- Maximum Loads . . . . . . . . . . . . . . .32 per node
- Node Repeaters . . . . . . . . . . . . . . . .SensorNet junction boxes
- Topologies Supported . . . . . . . . . .Daisy chain, Backbone, or Star
- Transmission Medium . . . . . . . . . .Single non-polarized unshielded twisted pair UTP 22 AWG
- Connector . . . . . . . . . . . . . . . . . . . . .Euro-style 2 pin removable plug 3.5 mm terminal block
- Terminating Resistor . . . . . . . . . . .120 ohms, switch selectable
- Physical Layer . . . . . . . . . . . . . . . . . .RS-485, transformer isolated, 2-wire
- Data Encoding . . . . . . . . . . . . . . . . .FM-0
- Link Layer Framing . . . . . . . . . . . . .SDLC/HDLC
- Link Layer Channel . . . . . . . . . . . . .Bi-directional, half duplex
- Collision Avoidance . . . . . . . . . . . .Polling by USB Module
- Application Protocol . . . . . . . . . . .Proprietary
- Network Nodes . . . . . . . . . . . . . . . .Domes, junction boxes, secondary TouchTracker, and SensorNet I/O unit
- Surge Protection
- SensorNet Gas discharge tube impulse rated at:
- DC breakdown voltage . . . . . . . .90 V
- Insulation resistance . . . . . . . . . .10,000 Mega ohms
- Capacitance . . . . . . . . . . . . . . . . . .2 pF max. 8/20 μs impulse
- discharge current . . . . . . . . . . . . .10 kA Ten 8/20μs impulses
- discharge current . . . . . . . . . . . . .5 kA
- Isolation transformer coupled . . .2000 Vrms
- PTC re-settable fuse protects transformer Transient voltage suppressors (TVS)
- Break down voltage . . . . . . . . . . .7.6�9.3 V
- Peak current . . . . . . . . . . . . . . . . . .40 A
- Capacitance . . . . . . . . . . . . . . . . . .2000 pf @ 1kHz
- USB: ESD suppressors protect USB lines by suppressing fast rising transients as specified in IEC 61000-4-2 and MIL-STD-883C (8k V discharge method)
- Environmental
- Temperature
- Operating . . . . . . . . . . . . . . . . . . . .10� to 50�C (14� to 122�F)
- Relative Humidity . . . . . . . . . . . .0 to 95% non-condensing
- Mechanical
- Length . . . . . . . . . . . . . . . . . . . . . . . .10.2 cm (4.0 in)
- Width . . . . . . . . . . . . . . . . . . . . . . . . .7.0 cm (2.8 in)
- Thickness . . . . . . . . . . . . . . . . . . . . .2.5 cm (1.0 in)
- Weight . . . . . . . . . . . . . . . . . . . . . . . . 0.5 kg (1.1 lbs)
- Regulatory Compliance
- EMC . . . . . . . . . . . . . . . . . . . . . . . . . .47 CFR, Part 15
- ICES-003
- EN55022
- CISPR 22
- Safety . . . . . . . . . . . . . . . . . . . . . . . . .UL 1950
- CSA C22.2 No 950
- TUV Rhienland EN60950
- IEC 950
|
|
 |
 |
 |
 |
|
 |

|