Detectors for Fire Alarm Systems

>

Beam & Duct Smoke Detectors for Fire Alarm Systems

We found 19 results matching your criteria.
Ideal for large commercial buildings, including government offices, schools and hospitals, beam and duct smoke detectors offer reliable fire protection by detecting the presence of smoke in air conditioning and ventilation ducts. Check out Security Store USA for accurate, reliable beam and duct smoke detectors for incorporating into your fire system.
Sort By:
Page of 2
SDI 2S-DUCT01 ductchecker Duct Detector Tester SDi AVchecker - AIR VELOCITY METER DUCT DETECTOR AVCHECKER
SDI Fire & Security Alarm System Tools

The ductchecker and dbchecker are ideal for the maintenance of fire and security alarm systems.

Ideal for Fire and Security Alarm System Maintenance The ductchecker and dbchecker from SDI are ideal for the maintenance of fire and security alarm systems. The ductchecker is an easy-to-use tool perfect for testing duct detectors to ensure they sample airstream properly, according to manufacturer’s instructions and required by the National Fire Protection Association. This portable, battery operated device includes hard case and sampling tube plugs, making it convenient for initial and semiannual duct detector testing.
• Simple to Use
• Portable
• Battery Operated
• Meets NFPA 72 Requirements
• Perfect for Annual and Semi-Annual Testing
• Easy to Read Display

  • Ensures duct detector will sample the air velocity correctly
  • Easy to use
  • Conforms to NFPA 72
  • Bosch D296 24V Projected Beam Smoke Detector Bosch D297 12 V Projected Beam Smoke Detector
    The D296 Projected Beam Smoke Detector is used in clear open structures such as arenas, atriums, auditoriums, ballrooms, churches, factories, museums, and warehouses. Each D296 detector consists of a transmitter, a receiver, and a remote annunciation plate. Because the transmitter and receiver typically mount on the ceiling or high on walls or columns, they provide an effective and unobtrusive means of supervising public areas for fire protection. The D306 Remote Indicator Plate, included with the D296, provides a convenient means of verifying detector status. Install it anywhere within 100 ft (30 m) of the beam receiver. The D306 has LEDs to indicate normal, trouble, and alarm conditions, and test points to monitor the detector circuit.
  • Operates over distances between 30 ft (9 m) and 350 ft (107 m)
  • Six levels of switch-selectable sensitivity
  • Built-in alignment sights and tamper protection
  • Automatic range adjustment, signal synchronization, and contamination adjustment
  • Remote indicator plate annunciates voltage, trouble, and alarm conditions
  • Switch-selectable alarm signal delay
  • Auxiliary Form C alarm relay

    REPLACES DS-DS240

  • The D297 Projected Beam Smoke Detector is used in clear open structures such as arenas, atriums, auditoriums, ballrooms, churches, factories, museums, and warehouses. Each D297 detector consists of a transmitter, a receiver, and a remote annunciation plate. Because the transmitter and receiver typically mount on the ceiling or high on walls or columns, they provide an effective and unobtrusive means of supervising public areas for fire protection. The D306 Remote Indicator Plate, included with the D297, provides a convenient means of verifying detector status. Install it anywhere within 100 ft (30 m) of the beam receiver. The D306 has LEDs to indicate normal, trouble, and alarm conditions, and test points to monitor the detector circuit.
  • Operates over distances between 30 ft (9 m) and 350 ft (107 m)
  • Six levels of switch-selectable sensitivity
  • Built-in alignment sights and tamper protection
  • Automatic range adjustment, signal synchronization, and contamination adjustment
  • Remote indicator plate annunciates voltage, trouble, and alarm conditions
  • Switch-selectable alarm signal delay
  • Auxiliary Form C alarm relay

    REPLACES DS-DS240

  • Bosch D340 Duct Detector Housing Bosch D341 Duct Detector Housing
    The D340 Duct Smoke Detector Housings mount on the ducts of heating, ventilation, and air conditioning (HVAC) systems to monitor the presence of smoke in the conditioned air. The housing works with the D285DH Photoelectric Duct Smoke Detector Head. The efficient housing design samples the air passing through a duct and detects potentially hazardous conditions. When smoke is detected, the detector sends an alarm signal to the control panel or HVAC control equipment that initiates the necessary action to control air handling systems.
  • For 1 ft (30.5 cm) to 10 ft (3 m) ducts with air velocity between 300 ft/min to 4000 ft/min (1.52 m/s to 20.3 m/s)
  • Easy duct tube installation through the housing cuts installation time
  • Detector test and reset without removing covers
  • Clear cover allows quick visual inspection
  • Tube filters, dust immune smoke detector, and easy disassembly for cleaning reduce maintenance time and cost
  • The D341 Duct Smoke Detector Housings mount on the ducts of heating, ventilation, and air conditioning (HVAC) systems to monitor the presence of smoke in the conditioned air. The housing works with all 24 VDC or VAC or 120 VAC, UL Listed four-wire control panels. The efficient housing design samples the air passing through a duct and detects potentially hazardous conditions. When smoke is detected, the detector sends an alarm signal to the control panel or HVAC control equipment that initiates the necessary action to control air handling systems.
  • For 1 ft (30.5 cm) to 10 ft (3 m) ducts with air velocity between 300 ft/min to 4000 ft/min (1.52 m/s to 20.3 m/s)
  • Easy duct tube installation through the housing cuts installation time
  • Detector test and reset without removing covers
  • Clear cover allows quick visual inspection
  • Tube filters, dust immune smoke detector, and easy disassembly for cleaning reduce maintenance time and cost
  • Bosch D342 Duct Detector Housing Bosch DS290 Smoke Detector Housing Kit
    The D342 Duct Smoke Detector Housings mount on the ducts of heating, ventilation, and air conditioning (HVAC) systems to monitor the presence of smoke in the conditioned air. The housing works with all 24 VDC or VAC, 220 VAC, or 240 VAC UL Listed four-wire control panels. The efficient housing design samples the air passing through a duct and detects potentially hazardous conditions. When smoke is detected, the detector sends an alarm signal to the control panel or HVAC control equipment that initiates the necessary action to control air handling systems.
  • For 1 ft (30.5 cm) to 10 ft (3 m) ducts with air velocity between 300 ft/min to 4000 ft/min (1.52 m/s to 20.3 m/s)
  • Easy duct tube installation through the housing cuts installation time.
  • Detector test and reset without removing covers
  • Clear cover allows quick visual inspection
  • Tube filters, dust immune smoke detector, and easy disassembly for cleaning reduce maintenance time and cost
  • DS290 Smoke Detector Housing Kit

    The DS290 Duct Smoke Detector Housing Kit includes:
    • One DS290 Duct Smoke Detector Housing
    • One Exhaust Tube
    • Two Tube Filter
    • Mounting hardware

    Note: The smoke detector head and sample tubes must be ordered separately.

    The DS290 Air Duct Smoke Detector Housing is designed to mount to the ducts of HVAC systems to monitor the presence of smoke in the conditioned air and may be used with the DS250DH Photoelectric Duct Smoke Detector or the DS260 Ionization Smoke Detector. It is designed to work on a 2-wire loop.

    Features

  • Ion and photoelectric models
  • Air velocity between 300 ft./min. (1.52 m/s) to 4000 ft./min. (20.3 m/s)
  • Easy duct tube installation through the housing, cuts installation time
  • Detector test and reset without removing covers
  • Detector test and reset without removing covers
  • Tube filters and dust immune smoke detector reduce maintenance & Easy disassembly for cleaning
  • Bosch DS291 Conventional 4-Wire Duct Smoke Detector Housing 120 VAC Commercial Products Group 30-3003D - Explosion Proof Air Duct Smoke Detector
    The DS291 Air Duct Smoke Detector Housing is designed to mount to the ducts of HVAC systems to monitor the presence of smoke in the conditioned air. They are designed to operate on 24 VDC/VAC or 120 VAC. The efficient housing design samples the air passing through a duct and allows the detection of a potentially hazardous condition. When smoke is detected, the detector sends an alarm signal to the control panel and/or HVAC control equipment that will initiate the necessary action to control air-handling systems.

    Features

  • For conventional four-wire loops & For ducts 12 in. (30.5 cm) to 10 ft. (3 m)
  • Ionization and photoelectric models
  • Alarm, auxiliary and trouble relay contacts
  • Air velocity between 300 ft./min. (1.52 m/s) to 4000 ft./min. (20.3 m/s)
  • Easy duct tube installation through the housing, cuts installation time
  • Detector test and reset without removing covers

    The DS291 Duct Smoke Detector Housing Kit includes:
    • One DS291 Duct Smoke Detector Housing
    • One Exhaust Tube
    • Two Tube Filters
    • Mounting hardware

    Note: The smoke detector head and sample tubes must be ordered separately.

  • Description
    The Model 30-3003D uses air sampling tubes to provide a cross sectional sampling of air moving through the duct. Inlet sampling tubes are available in four lengths: one foot, three feet, six feet, and ten feet.
    The length of the inlet sampling tube is determined by the width of the duct to be monitored. The inlet duct, therefore, specify the shortest sampling tube that is at least the width of the duct to be protected. It can then be cut to the exact length at the job site.
    Outlet tubes are one common length. Both inlet and outlet tubes are furnished with each detector.
    The Harrington Model 30-3003D Explosion-Proof Air Duct Smoke Detector is designed to detect the presence of smoke for the primary purpose of controlling blowers and dampers in air conditioning and ventilation systems and is intended for use in hazardous industrial and commercial locations. The unit mounts directly to heating, ventilating, and air conditioning ducts and utilizes a cross sectional sampling tube arrangement rather than a substitute for open area detection.
    The explosion-proof air duct smoke detector is intended to be connected to a control unit and function as part of a fire protection system. The 30-3003D is designed for use with a 4-wire system fire alarm control panel (2 wires for detector power and 2 wires for detector output).
    The detector operates on the forward light scattering principle, a technology that is based on more than 30 years of experience in advanced photoelectric detection systems.
    MODEL 30-3003D Explosion Proof Air Duct Smoke Detector Features
  • Explosion-proof housing is designed for use in Division 1, Class I, Groups C and D; Class II, Groups E, F, and G; Class III hazardous locations.
  • Trouble-free photoelectric operation.
  • Standard 4-wire 24 vdc operation.
  • Designed to meet ANSI/UL 268A smoke obscuration limits.
  • 600 to 4000 ft/min. airflow range.
  • Rugged design for environmental extremes.
  • Commercial Products Group DH604 - 4-Wire Air Duct Smoke Detector FENWALL FN-706000000 70600000000 4Wire Duct Detector No HD - FENWALL FN-706000000

    FEATURES

  • Approvals/Listing
    • UL 268A Listed File S1064
    • Factory Mutual Approved
    • CSFM Listed #3240-1076:121
    • NYC MEA Listed #134-95-E
    • City of Los Angeles Approved #RR8318
  • 24/120/240 VAC or 24 VDC Operation
  • Compatible with Fenwal Advanced Smoke Detectors
  • In-place Sensitivity Measurement (in % per foot obscuration)
  • Remote Indication, Test and Reset Capabilities
  • Easily Mounts to Round or Rectangular Ducts
  • Wide Range of Duct Sizes and Air Velocities
  • High Capacity Form C Alarm Relay Contacts
  • Clear Lexan Cover for Easy Viewing of Smoke Detector Status and Cleanliness

    DESCRIPTION

        The Fenwal Series DH-60 Air Duct Smoke Detector is designed for detecting particles of combustion in air handling systems. The DH-60 Duct Detector housing accepts the Fenwal Advanced CPD-7054D Ionization and PSD-7157D Photoelectric Smoke Detector Heads. Upon detection of smoke levels at the set point of the detector, the DH-60 Duct Detector can control a variety of devices, such as HVAC fans and dampers to prevent the spread of smoke throughout the facility.
  •  
  • High amperage relay contacts are provided for controlling such devices in the event of a fire. Supervisory contacts are also provided for signaling unit faults. A transparent Lexan cover over the detection chamber allows visual inspection of the duct detector’s chamber and the internal smoke detector status. Sampling is accomplished by sampling tubes that extend into the HVAC duct.

  • The DH-60 Duct Detector can operate as a 24 VAC, 120 VAC or 240 VAC powered stand-alone device or as a 4-wire 24 VDC powered device for use with Fire Alarm Control Panels. An integral normally energized trouble relay is used to supervise power and smoke detector head removal. Outputs provided can accommodate remote alarm and power indication, remote test and remote reset. Fenwal offers a range of remote accessories that operate in conjunction with the duct detectors. Figure 1 is a simplified parts breakdown of the DH-60 Air Duct Smoke Detector.
  •  
  • APPLICATION

    The Fenwal Series DH-60 Duct Detectors are suited for use with HVAC systems in commercial, industrial and institutional fire alarm applications.The DH-60 is easily mounted to both rectangular and round ducts from 8 inches (200 mm) to 12 feet (3.6 m) wide and is compatible with all ducts with air velocities between 500 and 4000 feet per minute (2.5 to 20 m/s). The Ionization and Photoelectric Smoke Detector heads listed above operate over this entire air velocity range.

    SAMPLING TUBES

    The operation of the DH-60 Duct Detector is based upon an air sampling principle. Two tubes extend into the HVAC duct to transport air from inside the duct into the duct detector sensing chamber and back out to the duct. If the sampled air contains a concentration of smoke greater than or equal to the alarm threshold of the internal smoke detector, the unit will alarm. The duct detector inlet supply sampling tube is selected according to the size of the HVAC duct. A separate exhaust tube is not required since an integral tube is molded into the housing to simplify installation.

    REMOTE INDICATORS/CONTROLS

    A series of easily installed remote indicators are available to add versatility and flexibility to the Fenwal Series DH-60 Duct Detectors. These attractive and functional devices provide convenient status information along with remote Test/Reset capabilities. The remote indicators are helpful when the detector is out of view or mounted in relatively inaccessible locations. The remote indicators can be used in both AC and DC applications. Figure 2 shows the faceplates of the RA-911, RA-912 and RA-913 remote indicator controls.

    FUNCTIONAL TESTING AND SENSITIVITY MEASUREMENT

    The Fenwal DH-60 Duct Detectors should be tested upon installation and once a year thereafter as stated in NFPA 72. All alarm signal devices, releasing devices, and extinguishing systems, as applicable should be disengaged before the test is performed and re-engaged at the conclusion of testing.The DH-60 Duct Detector may be functionally tested either by introducing smoke into the detector or activating the magnet test.
  •  
  •  Two separate magnet-locating slots are provided on the outside of the duct detector housing.Further, as stated in NFPA 72, Detector sensitivity should be checked within one year of installation and every alternative year thereafter. Fenwal offers the Model DST-003 handheld wireless infrared sensitivity tester that allows the sensitivity of installed operating detectors to be measured from the floor level. For details, please refer Fenwal Document 70.103.
  • FENWALL FN-706000000 70600000000 4Wire Duct Detector No HD - FENWALL FN-706000000


    FENWALL FN-706000000 70600000000 4Wire Duct Detector No HD - FENWALL FN-706000000

       
     