  Edwards Signal ED-116DEXMSA Hazard Location Strobe Beacon Amber Lens
Edwards Signal ED-116DEXMSA Hazard Location Strobe Beacon Amber Lens


 

Our Price : $1,685.00


Product Code: ED-116DEXMSA

Qty:

Description
 
The 116 Class Fire Alarm Strobe Lights, available in either a gray housing (116DEGEX-FJ) or a red housing (116DEGEXFJ-R) are in-rush current limited strobe lights. When pendant, wall or ceiling mounted, and with dome guard removed, they meet or exceed the requirements of UL 1971 Signaling Appliance for the Hearing Impaired.

The strobe is intended for indoor use in UL 1971 (signal appliance for the hearing impaired) listed compatible fire alarm systems. The strobe flashes a 360-degree beam of light approximately 65 times per minute with a UL 1971 125 cd ceiling and 60 cd wall light output per Figure 7 and Figure 8. With the guard installed, the strobe flashes a beam with an output of 86 cd ceiling and 51 cd wall. The strobe is also UL 1638 (visual signal appliance, private mode) listed with dome guard installed for both indoor and outdoor use, and other applications requiring electrical supervision of the signaling circuit field wiring. In addition, the strobe is rated for outdoor use in Canada. The 116 Class strobes are cUL listed to Canandian Standard ULCS526-07 (Visual Signal Device for Fire Alarm Systems), suitable for indoor and outdoor applications. The strobe features an enhanced synchronization circuit to comply with the latest requirements of UL 1971 and CAN/ULC-S526-07. Synchronized operation requires a separately installed synchronization control module. See Table 1 on page 5 for a list of compatible synchronization modules.

When assembled with an available mounting subassembly (116EX(R)-P, 116EX(R)-C, or 116EX(R)-C with 116EX(R)-B) and in accordance with these instructions, the 116 Class visual strobe signal is UL Listed as a Signaling Appliance for the hearing impaired for use in Class I, Division 1, Groups C and D, Class I, Division 2, Groups A, B, C, and D, Class II,
Division 1, Groups E, F, and G, Class II, Division 2, Groups F and G, and Class III, Division 1 and 2 hazardous locations with Operating Temperature Codes per Table 3 on page 5. Refer to "Specifications" on page 5 for more information. This strobe is UL and cUL Listed as a Type 3R and 4X enclosure.

Installation:

Install this unit in accordance with the applicable requirements in the latest edition of the National Fire Alarm Code (NFPA 72), National Electrical Code (NFPA 70), and
Canadian Electrical Code and CAN/ULC-S524-01/Standard for the Installation of Fire Alarm Systems. Wiring shall be in accordance with the applicable requirements in the National Electrical Code (NFPA 70) and CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.

Mount using one of the following applicable methods:

Pendant Mount Models (Figure 1 on page 2): Install the pendant mount module, Cat. No. 116EX(R)-P, to the 116 main housing. Tighten setscrew. Install an explosion-proof hanger box (not supplied). Secure 3/4" NPT threaded conduit (not supplied) to the box. Install the unit on the conduit. Ensure the conduit engages at least five full threads and then tighten the setscrew to secure the pendant mount module to the conduit. Connect the field earth ground wire to the ground screw or earth ground via conduit system. Wire in accordance with Figure 5 on page 3. See Table 3on page 5 for required supply wire temperature ratings.

Ceiling Mount Models (Figure 2 on page 2): Mount the ceiling mount module, Cat. No. 116EXC, using hardware (not supplied) that is suitable for the mounting surface. Connect field earth ground wire to the ground screw or earth ground via conduit system. Wire the unit in accordance with Figure 5 on page 3. See Table 3 on page 5 for required supply wire temperature ratings. Install main housing to the ceiling mount module. Tighten the setscrew to secure the 116 main housing to the ceiling mount module.

Bracket Mount Models (Figure 3 below): Install the ceiling mount module, Cat. No. 116EX-C, using hardware (not supplied) that is suitable for the mounting surface. Install the wall mount module, Cat. No. 116EX-B, to the 116 main housing. Tighten the setscrew to secure wall mounting module to the main housing. Run the unit's wiring through the elbow to the wall box. Connect field earth ground wire to ground screw or earth ground via conduit system. Wire the unit in accordance with Figure 5 on page 3. See Table 3 on page 5 for required supply wire temperature ratings. Install the main housing and 116EX-B wall mount module to the ceiling mount module. Tighten the setscrew
to secure the 116EX-B wall mount module to the ceiling mount module.

Specifications:

Agency Approvals:
UL 1971
ULC S526-02
UL1971
Can be synchronized
125cd ceiling, 60cd wall
Regulated 24Vdc(fwr)
.505A dc, .520Afwr
Class I Groups C & D, Class II Groups E, F, & G, Class III
Outdoor rated
NEMA 3R and 4X enclosure
Bracket (wall), ceiling, or pendant mount
Features
  • Strobe is intended for indoor use in UL 1971 (signal appliance for the hearing impaired) listed compatible fire alarm systems.
  • Strobe flashes a 360-degree beam of light approximately 65 times per minute.
  • UL 1971 125 cd ceiling and 60 cd wall light output per Figure 7 and Figure 8.
  • 116 Class strobes are cUL listed to Canandian Standard ULCS526-07.
  • Strobe features an enhanced synchronization circuit to comply.

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item: