Fire-Lite is pleased to announce the availability of the ANN-80-W, 80 character LCD annunciator. With exactly the same functions and UL-864 Ninth Edition listings as the red ANN-80 version, the ANN-80-W is designed to meet specific architectural job requirements where a white version is desired. The ANN-80-W is compatible with the MS-9050UD, MS-5UD-3 and MS-10UD-7 and all other ANN-BUS devices.The ANN-80 annunciator is a compact, backlit, 80-character
LCD fire annunciator that mimics the Fire Alarm Control Panel
(FACP) display. It provides system status indicators for AC
Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions.
The ANN-80 and the FACP communicate over a two-wire
serial interface employing the ANN-BUS communication format.
Connected devices are powered, via two additional wires, by
either the host FACP or a remote UL-listed, filtered power supply.
ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point
information including device type, zone, independent point
alarm, trouble or supervisory status, as well as any custom
alpha labels programmed into the control panel. It includes control
switches for remote control of critical system functions. (A
keyswitch prevents unauthorized operation of the control
switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of
each FACP. No programming is required, which saves time during
system commissioning.
- Operating voltage range: 18 VDC to 28 VDC.
- Current consumption @ 24 VDC nominal (filtered and nonresettable): 40 mA maximum.
- Ambient temperature: 32°F to 120°F (0°C to 49°C).
- Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F).
- 5.375” (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep.
- For use indoors in a dry location.
- All connections are power-limited and supervised.
The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S2424 • FM approved • CSFM: 7120-0075:211 • MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- Listed to UL Standard 864, 9th Edition.
- Backlit 80-character LCD display (20 characters x 4 lines).
- Mimics all display information from the host panel.
- Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
- Control switches can be independently enabled or disabled at the FACP.
- Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
- Keyswitch can be enabled or disabled at the FACP.
- Enclosure supervised for tamper.
- System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
- Local sounder can be enabled or disabled at the FACP.
- ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
- Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
- Time-and date display field.
- Surface mount directly to wall or to single, double, or 4" square electrical box.
- Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
- Can be remotely located up to 6,000 feet (1,800 m) from the panel.
- Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
- May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
- Up to eight ANN-80s can be connected on the ANN-BUS.
|
|
 |
 |
 |
 |
|
 |

|