Home > Shop Brands > FireLite Alarms by Honeywell >

  FireLite ANN-RLY Relay Board Mounts In Enclosure

FireLite ANN-RLY Relay Board Mounts In Enclosure


 

Our Price : $174.92


Product Code: ANN-RLY

Qty:

Description
 
The ANN-RLY relay module provides 10 programmable FormC relays when used with a compatible FACP (Fire Alarm Control Panel). The ANN-RLY module may be mounted inside the FACP main circuit board chassis or in the battery area of the enclosure using optional mounting bracket P/N: ANN-MBRLY. Reference Installation Instructions document #53033. The ANN-RLY and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. An additional two wires are used for 24-volt DC power. A single four-conductor unshielded cable may be used for both power and data communications. Up to eight ANN-BUS devices may be connected to the ANNBUS of each FACP.

Specifications:

Maximum ANN-BUS Voltage: 24 VDC

Maximum Current:

-Alarm: 75 mA
-Standby: 15 mA

Ambient Temperature: 32F to 120F (0C to 49C)
Relative Humidity: 93% 2% RH (noncondensing) at 32C 2C (90F 3F)
For use indoors in a dry location
Connections to FACP are power-limited and supervised
Relay Contact Ratings: 2 Amps @ 30VDC (Resistive) 0.5 Amps @ 30VAC (Resistive)

Agency Listings and Approvals: The listings and approvals below apply to the ANN-RLY. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status

UL: S2424
FM Approved
CSFM: 7120-0075:0222
Features
  • ANN-RLY connects to the ANN-BUS terminal on the FACP and requires minimal programming
  • Provides 10 programmable Form-C relays
  • Ten Form-C relays can be programmed for various functions; Alarm, Trouble, Supervisory, AC Loss, Waterflow Delay, Input Zones and Silenceable Alarm
  • Compatible with the MS9600LS, MS-9600UDLS, MS-9200 UDLS, MS-9050UD, MS-5UD-3, MPR-2001, MRP-2002 and MS-10UD-7
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC)
  • Up to eight ANN-BUS devices may be connected to the ANN-BUS of each FACP
  • Listed to UL Standard 864, 9th Edition

Share your knowledge of this product with other customers... Be the first to write a review