The Fire-Lite MS-9050UD is an Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, cost effective, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules, and comes with an extensive list of powerful features. The MS-9050UD programs just like Fire-Lites larger products, yet fits into applications previously served only by conventional panels.

The MS-9050UDs integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network.

The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include remote annunciators and reverse polarity/city box transmitter. (4XTMF)

Programming and Software:

Autoprogram (learn mode) reduces installation time.
Custom English labels (per point) may be manually entered or selected from an internal library file.
Two programmable Form-C relay outputs.
20 software zones.
Continuous fire protection during online programming at the front panel.
Program Check automatically catches common errors not linked to any zone or input point.

User interface:

LED Indicators
AC Power (green)
Fire Alarm (red)
Supervisory (yellow)
Trouble (yellow)
Alarm Silenced signals (yellow)

Keypad
16 key alpha-numeric pad.
Acknowledge/Step
Alarm Silenced
Drill (Manual Evacuate)
Reset (lamp test)

Ordering Options:

MS-9050UD: Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc., manual.
MS-9050UD Cabinet: Cabinet for MS-9050UD.
DP-51050: Optional dress panel for the MS-9050UD.
MS-9050UDTR-CE: Trim Ring for semi-flush mounting.
BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75.
BB-55F: Battery box, houses two 55 AH batteries
CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH.
BAT Series: Batteries, see data sheet DF-52397.
PRT/PK-CABLE: Cable printer/personal computer interface cable.
PRN-6F: UL listed compatible event printer. Uses tractor-fed paper.

Optional Modules:
4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED.

Compatible Annunciators:
ANN-80: Remote LCD annunciator mimics the FACP display
ANN-I/O: Input/Output Module for driving graphic annunciators or relays
ANN-S/PG: Serial/Parallel Printer Interface module for connecting printer to FACP

Addressable Devices:
CP355: Addressable low-profile ionization smoke detector.
SD355: Addressable low-profile photoelectric smoke detector.
SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor.
H355: Fast-response, low-profile heat detector.
H355R: Fast-response, low-profile heat detector with rate-ofrise option.
AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B350LP base included). CLIP MODE ONLY
BEAM355: Intelligent beam smoke detector.
BEAM355S: Intelligent beam smoke detector with integral sensitivity test.
D350PL: Photoelectric low-flow duct smoke detector.
D350RPL: Photoelectric low-flow duct smoke detector with relay option.
MMF-300: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-ofline resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC.
MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs.
MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox.
MMF-302: Similar to MMF-300, but may monitor up to 20 conventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors.
CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box.
Notification Appliance Circuit option requires external 24 VDC to power notification appliances.
CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500.
BG-12LX: Addressable manual pull station with interface module mounted inside.
I300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation).
SMB500: Used to mount all modules except the MMF-301 and M301.
MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F.
MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F.
CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F.
CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F

System Capacity:
Intelligent Signalling Line Circuits: 1
Addressable device capacity: 50
Programmable software zones: 20
Annunciators: 8

Electrical Specifications:

AC Power: 120 VAC, 60 Hz, 0.3 amps.
Battery: Two 12 V 18AH lead-acid batteries. Battery Charger
Capacity: 7 -18 Amp Hour (MS-9050UD cabinet holds maximum of two 18 Amp Hour batteries.
Communication Loop: Supervised and power-limited.

Notification Appliance Circuits:
Terminal Block provides connections for two NACs, Style Y (Class B) or. Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps. Endof-Line Resistor: 47 kohm, watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to the FireLite Device Compatibility Document for listed compatible devices.

Two Programmable Relays and One Fixed Trouble Relay:
Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised.

Cabinet Specifications:
Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep.
Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide.

Shipping Specifications:
Weight: 26.9 lbs. (12.20 kg.)
Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep

Temperature and Humidity Ranges:
This system meets NFPA requirements for operation at 0 - 49C/32 - 120F and at a relative humidity 93% 2% RH (noncondensing) at 32C 2C (90F 3F). However, the
useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27C/60 - 80F.

NFPA Standards:
The MS-9050UD complies with the following NFPA 72 Fire Alarm Systems requirements
LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory).
AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF).
REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.)
PROPRIETARY (Automatic, Manual and Waterflow).
CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised).

Agency Listings and Approvals:
The listings and approvals below apply to the basic MS-9050UD control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
UL: S624
FM approved
CSFM: 7165-0075:210
Features
  • Auto-program (learn mode) reduces installation time.
  • Reports two devices set to the same address.
  • On-board DACT.
  • 20 software zones.
  • Two independently programmable Class A or Class B NAC circuits.
  • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices.
  • Complies with UL 864 9th Edition requirements.
  • Remote Acknowledge, Silence, Reset and Drill via addressable monitor modules.
  • Two programmable relays and one fixed trouble relay.
  • Integral 80-character LCD display with backlighting.
  • Real-time clock/calendar with automatic daylight savings control.
  • History file with 500 event capacity.
  • Detector sensitivity test capability (NFPA 72 compliant).
  • Maintenance alert warns when smoke detector dust accumulation is excessive.
  • One person audible or silent walk test with walk-test log and printout.
  • Point trouble identification.
  • Waterflow (nonsilenceable) selection per monitor point.
  • System alarm verification selection per detector point.
  • PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant).
  • Up to eight ANN-BUS annunciators
  • SLC Communication Loop:
  • Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements.
  • 50 addressable device capacity (any combination of addressable detectors and modules).
  • Compatible with FireLites addressable devices (refer to SLC Wiring Manual).
  • Notification Appliance Circuits (NACS):
  • Two independently programmable output circuits. Circuits can be configured for the following outputs
  • Style Y (Class B)
  • Style Z (Class A)
  • Door Holder Service
  • Aux Power Source
  • Silence Inhibit and Autosilence timer options.
  • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability.
  • Selectable strobe synchronization per NAC.
  • 2.5 amps total power for NACs.