Home > Shop Brands > FireLite Alarms by Honeywell >

  FireLite MS10KT Ten Zone Fire Alarm Control Panel

FireLite MS10KT Ten Zone Fire Alarm Control Panel


 

Our Price : $859.40


Product Code: MS10KT

Qty:

Description
 
The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download.

Each of these FACPs is compatible with System Sensorís microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS-10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to Fire-Lite Device Compatibility Document for a complete listing of compatible devices.

Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity.

Activation of a compatible smoke detector or any normally-open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MS-5UD-3E and the MS-10UD-7E offer the same features as the MS-5UD-3 and MS-10UD-7 but allow connection to 220/240 VAC.

Specifications:

Programming and Software:
Can be programmed at the panel with no special software or additional equipment.
Programmable Make/Break Ratio.
Upload/Download (local or remote) of program and data via integral DACT.

User Interface:
Built-in DACT (Digital Alarm Communicator/Transmitter).
Integral 80-character LCD display with backlighting and keypad.
Real-time clock/calendar with automatic daylight savings adjustments.
ANN-Bus for connection to remote annunciators.
Audible or silent walk test capabilities.
Piezo sounder for alarm, trouble, and supervisory.

Ordering Information:
MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet).
MS-5UD-3E: Same as above with 240 VAC FLPS-3 power supply.
MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet).
MS-10UD-7E: Same as above with 240 VAC FLPS-7.

Optional Modules:
CAC-5X: Optional Style Z (Class A) Converter Module. Converts Style B (Class B) Notification Appliance Circuits to Style D (Class A) and Style Y (Class B). Connects to J2 on the MS- 5UD-3(E) and MS-10UD-7(E) main circuit board and to J7 on the MS-10UD-7(E).

4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5.

Compatible Annunciators:
ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACPís LCD.
ANN-LED: Mounts in the DP-51050 dress panel and provides three LEDs for each zone: Alarm, Trouble, and Supervisory.
ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays.
ANN-S/PG: Serial/parallel printer gateway. Provides a connection for a serial or parallel printer.
ANN-I/O: Driver module. Provides connections to a user-supplied graphic annunciator.
Features
  • Listed to UL Standard 864, 9th edition.
  • Built-in DACT (Digital Alarm Communicator/Transmitter)
  • Style B (Class B) IDC (Initiating Device Circuit)
  • MS-5UD-3 - five IDCs.
  • MS-10UD-7 - ten IDCs.
  • Style Y (Class B) NAC (Notification Appliance Circuit) - special application power
  • MS-5UD-3 - four NACs.
  • MS-10UD-7 - four NACs.
  • Notification Appliances may be programmed as
  • Silence Inhibit.
  • Auto-Silence.
  • Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices.
  • Selective Silence (horn-strobe mute).
  • Temporal or Steady Signal.
  • Silenceable or Nonsilenceable.
  • Optional CAC-5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for MS-10UD-7).
  • Form-C Relays for Alarm, Trouble and Supervisory - Contact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive).
  • 3.0 A total system current for MS-5UD-3.
  • 7.0 A total system current for MS-10UD-7.
  • Optional Dress Panel DP-51050.
  • Optional Trim Ring TR-CE for semi-flush mounting.
  • 24 volt operation.
  • Low AC voltage sense.
  • Alarm Verification.
  • PAS (Positive Alarm Sequence).
  • Automatic battery trickle charger.
  • Optional 8 zone Relay Module ANN-RLY.
  • Optional Remote Annunciator ANN-80.
  • Optional Remote Printer Gateway ANN-S/PG.
  • Optional LED Annunciator Driver ANN-I/O.
  • Optional 4XTMF module (conventional reverse polarity/city box transmitter).

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Shop Brands > FireLite Alarms by Honeywell
 
 

Enter your email for a chance to WIN $100 Amex Gift Card.

Please Enter Your Email Address

*One entry per household please