  FireLite SLC-2LS Addressable L SLC Loop for REV2 MS9600LS

FireLite SLC-2LS Addressable L SLC Loop for REV2 MS9600LS


 

Our Price : $445.91


Product Code: SLC-2LS

Qty:

Description
 
Fire-Lite's MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Control Panels) with an extensive list of powerful features. The combination of Fire-Lite's newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLSE FACP, offer the latest in fire protection technology. LiteSpeed is a patented technology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the system polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification circuits in under 10 seconds. With this new polling scheme, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Circuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules.

The FLPS-7 power supply is a separate board while all other electronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabinet. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the chassis with the electronics can be quickly installed with two bolts.

The MS-9600UDLS(E) includes a factory-installed DACT-UD2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Station via internet (optional IPDACT installed) or the public switched telephone network.

Optional modules, which plug into the main circuit board, are available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download software and remote power expansion. FM APPROVED to UL ANSI 864.

Specifications:

System Capacity:

Intelligent Signalling Line Circuits: 1 expandable to 2
Intelligent detectors: 159 per loop
Addressable monitor/control modules: 159 per loop
Programmable software zones: 99
ANN-BUS devices: 8
ACS Annunciators: 32
LCD Annunciators: 3

Electrical:

Primary input power:

-120 VAC, 50/60 Hz, 3.0 A
-240 VAC, 50 Hz, 1.5 A

Battery: 27.6 VDC @ 1.0 A (max)
Maximum battery charger capacity: 26 AH
Minimum battery: 12 AH

Communication Loop: 24 VDC nominal, supervised and power-limited

Notification Appliance Circuits: terminal block provides connections for four Style Y (Class B) or two Style Z (Class A) NACs

Maximum signaling current per circuit: 3.0 A
End-of-Line Resistor: 4.7 K ohms, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC Supervised and power-limited Refer to panel documentation and Fire-Lite Device Compatibility Document for listed compatible devices

Two Programmable Form-C Relays and One Fixed Trouble
Form-C Relay: Contact rating: 2.0 A @ 30 VDC (resistive) 0.5 A @ 30 VAC (resistive

Four-wire Resettable Special Application Power (24 VDC nominal): Up to 1.5 A for powering four-wire smoke detectors. Power-Limited, nonsupervised Refer to Fire-Lite Device Compatibility Document for listed compatible devices

Nonresettable Special Application Power #1 (24VDC nominal) TB3, Terminals 3 (+) & 4 (-):

Maximum ripple voltage: 10 mVRMS
Total DC current available from each output is up to 1.5 A Power-limited, nonsupervised

Nonresettable Special Application Power #2 (24VDC nominal) TB3, Terminals 5 (+) & 6 (-):

Maximum ripple voltage: 10 mVRMS
Total DC current available from each output is up to 1.5 A Power-limited, nonsupervised

Cabinet:

Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.67" (1.70 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.21" (13.23 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide

Shipping:

Dimensions: 20.00" (50.80 cm) high, 22.5" (57.15 cm) wide, 8.5" (21.59 cm) deep
Weight: 27.3 lbs (12.38 kg)
Features
  • Easy mount chassis
  • 7 amp switching power supply
  • Large enclosure allows 18 amp-hour batteries
  • DACT-UD2 plug-in communicator standard with MS-9600UDLS/E
  • Optional IPDACT Internet Protocol Digital Alarm Communicator/Transmitter
  • Four Style Y (Class B) or two Style Z (Class A) NAC circuits
  • Selectable strobe synchronization per NAC for System Sensor, Wheelock, and Gentex devices
  • Automated control of ACC-25/50(ZS/T) audio speaker circuits
  • ANN-BUS for connection to following optional modules