Honeywell Expansion Modules & Accessories

  Accessories
  Expansion Modules
  ZBRIDGE Intelligent Energy Management
Honeywell Expansion Modules & Accessories Increase the functionality of your security system with Honeywell's full line of expansion devices and accessories.
Accessories
Accessories
Expansion Modules
ZBRIDGE Intelligent Energy Management
ZBRIDGE Intelligent Energy Management
Sort By:
Page of 3
Ademco / Honewell 1322/TF3 12 Volts/20 VA Transformer Ademco / Honeywell 1361 AC Transformer 16.5V/ 40VA
General Information

Part Number1322/TF3
Brand NameAdemco
ManufacturerHoneywell International, Inc
Manufacturer Part Number1322/TF3
Product Model1322/TF3
Product TypeStep Down Transformer
UPC781410162792
Weight0.7 lbs

Miscellaneous


CompatibilityAdemco AD12612 Auxiliary Power Supply / Battery Charger

Power Description


Frequency60 Hz
Input Voltage110 V AC
Output Voltage12 V AC

Technical Information


Power Rating20 VA.
Ademco 1361 AC Transformer 16.5V/ 40VA
Ademco / Honeywell 4100SM - Serial Interface Module Ademco / Honeywell 4101SN -  V-Plex Single Output Relay Module
  • Interface for printer for: VISTA-50P, VISTA-100, VISTA-128B and VISTA-128FB

  • Direct wire download interface for : 4140XMP, VISTA-40, VISTA-50P, VISTA-100, VISTA-128B and VISTA-128FB

  • The ADEMCO 4101SN V-Plex Single Output Relay Module is an accessory for use with ADEMCO control panels that support serial number addressable polling loop output devices.

    The 4101SN features the following:

    • Form C relay contacts rated at 2A, 28VACNDC with contact supervision.
      The position of the relay is supervised, but not the actual external contact wiring.
      Note: Some panels may not support this feature. 
    • One class B/style B EOLR-supervised aux input zone. 
    • Operating power and communication with control panels via the addressable V-PlexTM polling loop. 
    • Electronics mounted in a small plastic case with tamper-protected cover. Suitable for residential and commercial burglary and fire installations.
    Addressable Relay Module 781410197183

    Specifications:

      Physical: 2 1/8" x 3 1/4" x 1" (53mm x 84mm x 25mm)

      Electrical:

    • Polling loop input voltage range: 8-14VDC
    • Addressable polling loop current draw: 7mA
    • Relay contact rating: 2A @ 28VAC/VDC, both resistive and inductive loads

      Aux Zone:

    • 10K EOLR (internal when white jumper intact; external when white jumper cut)
    • 300 ohm max zone resistance (excluding EOLR)
    • Responds to open or short circuit fault having 250ms or longer duration
    • Class B (style B when used with panels providing earth ground fault detection)

      Agency Listings:

    • UL985 Household Fire
    • UL1023 Household Burglary
    • UL609 Commercial Burglary
    • ULCommercial Fire
    • CSFM (pending)
    • FM (pending)
    • MEA (pending)
    Ademco / Honeywell 4190SN - Two-Zone Remote Point Module Ademco / Honeywell 4204 - Intelligent Relay Board
    Two-Zone Remote Point Module

    The ADEMCO 4190SN addressable V-PlexTM module is a two-zone expander which allows use of the available expansion zones provided by ADEMCO controls that support V-Plex devices.

    • Serial mode programmable
    • Left Zone - EOLR supervised, open or closed circuit sensors
    • Right Zone - unsupervised, closed circuit sensors
    • UL listed for fire and burglary installations
    Features:

    The 4190SN consists of two detection loops, known as the left (primary) and right (secondary) loops. The left loop can be used for:

    • Closed-circuit devices with or without EOLR supervision
    • Open-circuit devices, with EOLR supervision
    • Fast-response (10 millisecond) devices

    Follow the chart below for cutting the correct jumpers and choosing the correct resistor when using the left loop. The right loop can be used for:

    • Closed-circuit devices only
    • Has no EOLR supervision
    • 400 millisecond response time  

    The jumpers do not affect the operation of the right loop. The right loop cannot be used alone.

    Supervision:

    The tamper/supervision response of the 4190SN is determined by the zone response type assigned to the left loop zone. While the system is armed, tamper/supervisory faults will report as alarms if the left loop zone is assigned a burglary response type and will report as troubles if the left loop zone is assigned a non-burglary response type (i.e., fire, panic, aux). While the system is disarmed, tamper/supervisory will always report as troubles.

    Specifications:

      Operating Temperature:

    • 20C to +60C

      Operating Relative Humidity:

    • 0-95% non condensing

      Operating Voltage:

    • 7-14VDC, for V-Plex System

      Quiescent Current:

    • 1.2mA (LED off), 5.0mA (LED on)

      Loop Current:

    • 2 amps, max.

      Complete Short Detection:

    • <10 ohms

      Resistive Short Detection:

    • (10-400) ohms during normal polling; (10-800) ohms at application of polling loop power

      Power-On Short Detection:

    • Overload Detection:
    • Loop power level is, 6VDC

      Dimensions:

    • 4 1/8" L x 9 1/16" W x 7/8" D

      Agency Listing:

    • UL1610 - Commercial Burglary Alarm - central station alarm units
    • UL864 - Commercial Fire Alarm
    • UL985 - Residential Fire Alarm
    • UL1023 - Household Burglary - alarm system units
    • UL609 - Commercial Burglary - local alarm units
    • UL365 - Commercial Burglary - police station alarm units
    • CUL
    • CSFM
    • FM
    • CE
    Intelligent Relay Board

    When your installation requirements call for additional relay outputs, the 4204 is your answer. The 4204 Intelligent Relay Board adds relays which are connected to the Control/Communicator via the control's console wiring. The relay outputs are programmed by the appropriate control for a variety of functions.

    The 4204 is ideal for applications that require additional sounding devices, strobe lights or other devices that need or desire to be controlled by the control panel.

    The 4204 is housed in a white plastic case for wall mounting and can be mounted in a Universal Can. If the 4204 is remotely mounted, there are provisions to tamper protect the cover, and the unit so that it cannot be disconnected from the console wiring without detection be the control.

    Features:

    • Adds 4 programmable relays to selected VISTA panels
    • Easily wired to control panel
    • Fits inside Universal Control Cabinet
    • Expand existing security systems with additional output capabilities
    • Attractive case design
    • Check Control Documentation for compatibility with 4204

    Specifications:
    • Physical: 6 1/2" x 4 1/4" x 1 1/4" (169mm x 108mm x 32mm)
    • Electrical:
      - Voltage: 12VDC (from control's remote consloe connection points)
      - Current: 15mA standby plus 40mA per active relay
    Ademco / Honeywell 4204CF - Supervised Notification Appliance Module Ademco / Honeywell 4208SNF - Universal Expander Module

    The 4204CF provides two programmable, on-board, styled B on selected panels supervised notification appliance outputs; applications include supervised bells, strobes, sirens or interface to other equipment.

    Addressable Universal Expander Module

    The ADEMCO 4208SNF Remote Point Module (RPM) is a UL listed 8 zone expander that provides (6) class B and (2) class A expansions zones to any VISTA Fire/Burg control panel that supports serial V-Plex polling loop devices.

    FEATURES:
    • Can be used on controls that support up to 250 zones
    • Provides up to six Class B supervised zones using external 10k EOL resistors and two Class A supervised zones using built-in 10k EOL resistors
    • Powered from addressable loop or optionally powered from an external DC power supply to reduce current draw from the addressable loop
    • Each zone is identified by a unique serial number, which is assigned via on-board DIP switches
    • Detects faults an all zones with 400msec of occurrence. Two Class B zones can be optionally set for fast (10msec) response via on-board DIP switches
    • Provides cover tamper protection, which may be enabled or disabled via on-board DIP switches
    Class B to Class A Zone Converter Features
    • Allows up to two Class B control panel zones to be converted into Class A zones
    • Control panel’s response time to faults on the module’s Class A zones is equal to the response time of the control panel’s converted Class B zones plus one msec
    • Must be powered from an external 12vdc power supply such as the 12v auxiliary power output on the control panel

    Specifications:

      Physical:

    • 6-7/16" W x 4-1/4" H x 1-1/4" D (163mm x 108mm x 32mm)

      Electrical: – Addressable V-Plex loop Voltage: 11v nominal; 8.7 - 14VDC range
      - Current: 33.6mA when polling loop provides power to module; 0.6mA when 12VDC input provides power to module
      – 12VDC Input Voltage:
      12V nominal: 9.4 - 14 VDC range
      – Current: 33mA when this input provides power to module (optional)

    • Used as a Class A Converter
      – 12VDC Input Voltage:
      12VDC nominal, 9.4 - 14VDC range, –
      - Current: 22mA

      AGENCY LISTINGS:

    • UL985 Household Fire
    • UL1023 Household Burglary
    • UL609 Commercial Burglary
    • UL864 Commercial Fire
    • CSFM
    • FM
    • CUL
    • CE (requires part#N6361)

      MOUNTING INSTRUCTIONS:

      When used as a zone expander, the 4208SNF may be placed inside the control panel cabinet or mounted remotely. When used as a Class B to Class A zone converter, the 4208SNF must be placed inside the control panel cabinet.

      EXPANDER SENSOR LOOP RESPONSE:

    • Slow: 400msec (all loops)
    • Fast: 10msec (options for loops A and B)

      EXPANDER SENSOR LOOP CURRENT:

    • 0.52mA (normal)
    • 1.3mA_ (shorted)

      Note: Addressable loop input = 11VDC, no external power input required

      SENSOR LOOP MAX. RESISTANCE:

    • Loops A - F (Class 8); Up to 300 ohms of wire resistance + 10k EOLR
    • Loops G, H (Class A); Up to 150 ohms of wire resistance on each side

      Power Input Source Expander/Converter Current Draw from Addressable Loop (all zones shorted) Current Draw from External Power (all zones shorted)
      Addressable Loop Only Expander 33.6mA N/A
      Addressable Loop and External Power Input Expander 0.6mA 33mA
      External Power Input Only Converter N/A 22mA
    Ademco / Honeywell 4208U - Addressable Loop Expansion Module Ademco / Honeywell 4219 - 8 Wired Zone Expander
    Features
    • Can be optionally powered from an external DC power supply to reduce the amount of current draw from the polling loop
    • Uniquely identifies eight EOLR supervised zones (all zones use 10K resistors, supplied)
    • DIP Switches can be used to set zone numbers or serial numbers
    • When used in the serial number mode, each serial number in the selected group can be assigned to any zone number
    • Loops A & B can be programmed for fast (10msec) response
    • Provides cover tamper protection, which may be enabled or disabled via on-board DIP Switches

    Specifications:

      Physical:

    • 6-7/16" W x 4-1/4" H x 1-1/4" D (163mm x 108mm x 32mm)

      Electrical: Polling Loop Voltage

    • 11V nominal; 8.7 - 14VDC range

      Current:

    • 33.6mA when polling loop provides power to module, 0.6mA when 12VDC input provides power to module. See chart below.

      Input Voltage:

    • 12VDC nominal; 9.4 - 14VDC range

      Expander Sensor Loop Response:

    • Slow: 400msec (all loops)
    • Fast: 10msec (option for loops A and B)

      Expander Sensor Loop Current:

    • 0.52mA (normal)
    • 1.3mA (shorted)
      NOTE: These currents apply wneh polling loop input = 11VDC and 10VDC input is not connected to external supply

      Sensor Loop Max. Resistance:

    • Up to 300 ohms of wire resistence + 10K EOLR

      Agency Listings:

    • UL985 Household Fire
    • UL1023 Household Bulgary
    • UL609 Commercial Burglary
    • UL864 Commercial Fire
    • CSFM
    • FM (Pending)
    • CUL
    • CE (requires #N6361)

      For UL Listed Commercial Fire Usage:
      Use N.O. contacts. Style B supervise these loops using Model #EOL 100 fire listed 10K EOLRs (purchased separately).
      For UL Listed Commercial Burglary Usage: Use N.O. or N.C. contacts. Supervise using EOLRs supplied.

      Power Input SourceCurrent Draw (all zones shorted)
      From Polling LoopFrom External Power
      Polling Loop Only33.6mAN/A
      Polling Loop and External Power Input0.6mA33mA
    DO NOT USE WITH CARBON MONOXIDE DETECTOR

    Wired Zone Expander

    • Adds up to 8 end-of-line hardwired supervised zones
    • Easily wired to Control Panel
    • Fits inside Universal Control Cabinet
    • Expand existing security systems easily
    • Attractive case design
    • Supported on VISTA-20HW

    4219 WIRED ZONE EXPANDER
    When your installation requirements call for an additional 8 hardwired zones for new or existing installations, the 4219 is your answer. The 4219 Wired Zone Expander adds up to 8 EOLR supervised zones which are connected to the Control/Communicator via the control's console wing

    The 4219 is ideal for expanding existing hardwired jobs without changing the control panel. The ability to add multiple zone expanders to gain more hardwired zones offers maximum protection with minimum cost.

    The 4219 is housed in a white plastic case for wall mounting and can be mounted in a universal cabinet. If the 4219 is remotely mounted, there are provisions that tamper-protect the unit so that it cannot be disconnected from the console wiring without detection by the control.

    Specifications:

    • Dimensions: 6 1/2" x 4 1/4" x 1 1/4" (169mm x 108mm x 32 mm)
    • Electrical:
      - Voltage: 12VDC (from control's remote console connection points)
      - Current: 35mA
    Ademco / Honeywell 4229 - Wired Zone Expander / Relay Board Ademco / Honeywell 4297 - Isolation / Extender Module
    DO NOT USE WITH CARBON MONOXIDE DETECTOR

    Wired Zone Expander / Relay Board

    • Provides 8 end-of-line supervised zones and 2 on-board programmable form C relays
    • Connection made to the control's console wires
    • Supported on VISTA-20HW
    >Isolation / Extender Module

    The 4297 V-Plex Loop Isolation/Extender Module offers dual benefits for commercial applications. As an isolation module, the 4297 allows installers to group selected zones on one loop. For example, fire and burglary zones may be grouped separately; essentially isolating one from another. This isolation feature prevents failure in one loop from compromising the integrity of any other loop. The 4297 Module also gives installers the flexibility to extend system-wide wiring capability, from approximately 4000 ft to 8000 ft., without the added expense of additional hardware or control panels.

    • Isolate open and short circuit faults from main V-Plex loop
    • Provides additional V-Plex loop current
    • V-Plex loop isolation between primary and extended loop
    • Fully supervised
    • Separate DC input, no current drain from primary V-Plex loop
    • Monitors DC power input

       
     
    Increase the functionality of your security system with Honeywell's full line of expansion devices and accessories.

     
     