Honeywell’s SC100 Series Seismic Vibration Sensors were
designed to protect high-value and high-risk assets in
financial, retail and other applications.
The SC100 model detects vibrations arising from attempts
to disturb solid structures including fixed ATMs, bank
vaults, safes and doors. The SC100 can be installed in new or existing
security systems and offer a higher level of protection and
false alarm immunity than traditional shock sensors, which
often lack the ability to discriminate between ambient
vibration and real attacks.
The SC100 Series contain several unique features that
reduce installation time and costs—including a Universal
setting that lets dealers choose between safes and vaults
with the change of a dip switch, integrated end-of-line
(EOL) resistors that improve connectivity to the control
panel, a built-in diagnostic tool and a compact size that
enables placement inside small areas.
 Features
- Detects attacks on
Bank vault doors, ATMs, night deposit
safes, strong room vaults, modular
vaults, vending machines, freestanding
safes, hatches, gates, chests and other
objects with a solid structure
- Detects attacks from
- Heavy strokes or gross attacks from
sledgehammers or explosives
- Repeated knocks from hammers
and chisels
- Drilling, mechanical cutting, acetylene
torches, thermal cutting, water-cooled
diamond drills, water jet cutting tools,
hydraulic jacks (SC100 only) - Compact size
Smallest available on market so fits
easier when space is limited
- Universal (ATM and vault)
The SC100 can also be used for ATMs
and night deposit safes by the simple
change of a dip switch. No separate
sensors are required.
- Drilling shield (standard)
Protects electronics inside against
sabotage
- Extended temperature
Allows operation in extreme temperature
conditions (-40° F to 158° F)
- Remote sensitivity reduction input
Option to reduce sensor sensitivity
remotely during maintenance on ATMs,
thereby reducing false alarms
- Multi-compatible mounting plate fits
on pre-fab holes
Fits on most pre-drilled mounting holes
from other seismic sensors, preventing
time consuming drilling/threading. The
same mounting plate can be used for
mounting on concrete and welding
on steel.
- Integrated End-of-Line
(EOL) resistors EOL resistors for alarm as well as
tamper loop are already incorporated,
saving installation time and reducing
service calls
- Integrated temperature alarm
The SC100 and SC105 will alarm if
the temperature exceeds 185° F.
Additionally the SC100 version alarms
when temperature rises faster than 6° F
per minute.
- Diagnostic LED Built-in tool easily selects correct sensitivity; no
time consuming external tools required
- Selectable sensitivity
Four different sensitivity settings adapt
to required range and environmental
conditions
- Remote testing and test transmitters
Input to remotely start functional test
with help of SC113 (Internal Test
Transmitter) or SC115 (External Test
Transmitter). If no test transmitter is
available, it is possible to test internal
electronics with this test.
- Available accessories
Mounting plate, keyhole protection kit,
day/night kit, Internal Test Transmitter,
armed cable and External Test
Transmitter. This range of accessories
allows the SC100 and SC105 Seismic
Sensors to be mounted in a wide range
of applications.
- Listed to UL639
- Listed to ULC-S306
- Specifications SC100 SC105
- Power Requirements Supply Voltage 8 – 16VDC, nominal 12VDC
- Current Consumption Typical 3 mA @ 12VDC
- Sensitivity Adjustable Sensitivity 4 levels by DIP Switches
- ATMs/Vault Selection by DIP switch N/A
- Delayed Triggering N/A by DIP switch
- Reduced Sensitivity Input For maintenance & Service: Active low (<1.5 VDC)
- Detection Radius 16.4' 9.8'
- Alarm Algorithm
- Highly sensitive to all known
- attacks while rejecting known false
- alarm sources by innovative filters
- and firmware
- Similar to the SC100, but adjusted for
- noisy environments such as public
- areas where ATMs may be located
- Alarm Outputs Solid State Relay (Change Over) 30VDC/100 mA; Type C 30 VDC/100 mA; Type A
- Open Collector Active low during alarm
- Alarm Hold Time Approx. 2.5 secs
- Sabotage Protection Pry-off and Cover Switch 30 VDC/100 mA
- Low Supply Voltage Alarm < 7 VDC
- Temperature Alarm 185° F, 23° F, 41° F
- Internal Functional Alarm Stainless steel drill shield
- Inputs Remote Test Active low 1.5 VDC, test duration < 0.5 sec
- Reduced Sensitivity Input Active low 1.5 VDC, test duration < 0.5 sec
- Sensitivity reduction to 12.5 %
- Installation Tool A noise and alarm indicator is incorporated to support sensitivity setting.
- Environmental
- Conditions
- Maximum Humidity 95% RH (non-condensing)
- Operating Temperature -40° F – 158° F
- Storage Temperature -58° F – 158° F
- Environmental Class (VdS) III
- Housing Protection Category IP43
- Housing Dimensions 3.15" H x 2.36" W x .83" D
- Chassis and Cover Die-cast metal
- Color RAL7035 (light gray)
- Weight .5 lbs.
|
|
 |
 |
 |
 |
|
 |