VISTA-21IP and 6160 Kit
VISTA-21iP - Control Panel & Honeywell 6160 - 32 Character Alpha Display Keypad
oneywells high capacity, feature-rich VISTA-21iP lets you deliver more
value to your customers on each and every sale. The VISTA-21iP provides
up to 48 zones of protection, an on-board IP connection, graphic keypad
support and dual partitions. The VISTA-21iP gives you the ability to
send alarm signals and upload/download via an Internet Protocol (IP),
improving the speed at which information can be delivered to and from
the control panel. When used with an optional AlarmNet GSM that snaps
right on the board, the VISTA-21iP can be installed in premises without
TELCO lines guaranteeing communication independent of any
infrastructure. The panels installation advantages, innovative
end-user benefits and robust system capacity make the value-priced
VISTA-21iP an ideal choice for higher-end installations. Features: Internet alarm reporting and uploading/downloading capability via on-board AlarmNet Internet Communicator Supports four graphic touchscreen keypads Wireless keys can be programmed without using zones Eight on-board hardwired zones standard (15 when Zone Doubling feature is used) 40 hardwired expansion zones 40 wireless expansion zones Two low current on-board trigger outputs 100 Event Log viewable at system keypads with time/date stamp 48 system user codes assignable to either partition Expandable to 48 total zones when used with hardwired and/or wireless expansion modules Two independent partitions plus a common partition Global arming from any system keypad Goto function to view or operate one partition from the other Separate partition account numbers 16 output devices Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10ฎ devices (when used with a 4300 Transformer) Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes Supports four-wire, and up to 16 two-wire smokes Works with Sentrol CleanMe maintenance signal Multiple actions on output devices depending on system state Turns lights off when system arms Turns the same light on when system disarms Flashes same lights when system is in alarm Built-in phone line cut monitor with programmable delay and annunciation options Display on system keypads Trigger local sounders Trigger system bell Security Dealer Features Automatic System Load Shed
During extended AC power fail, the system battery will be disconnected
to prevent irreversible battery failure. Reduces service calls to
replace batteries. Dynamic Signaling Reduces redundant
reporting to the central station when multiple reporting methods are
used; i.e. digital dialer and AlarmNet radio Valuable End-User Features
Viewable on system keypads: Exit countdown Time and date display* Event log* Auto keypad backlighting on entry Keyswitch arming Programmable macro buttons and single-button arming Supports a variety of wireless remote controls for single-button operation User Scheduling Automatically activates X-10 and relays at programmed times Latchkey reports to pagers Auto arm/disarm User access time windows Supports up to four end-user numeric pagers VIP Module allows system control from any touchtone phone Chime by zone
*Requires custom alpha keypad Electrical Specifications: Aux. power: 12VDC, 600mA maximum Seven hour standby at 400mA aux. load with four amp hour battery 16.5VAC/40VA transformer Alarm output: 12VDC, 2.0 amps max. For agency listed installations, combined aux. and alarm output cannot exceed 700mA Output Control: Supports up to four relay boards (up to 16 relays) Optional X-10 transformer/interface (part no. 4300) may be used to control up to 16 X-10 receiving devices Zones: Eight hardwired zones (15 with zone doubling) Selectable response: 10msec, 350msec, 750msec Assignable to any partition 20 selectable zone types plus four configurable zone types Programmable swinger suppression Expansion Devices: 4219 Eight hardwired zones 16mA--> 4204 Up to four relays 15mA standby (each active relay draws an additional 40mA) 4229 Eight hardwired zones and two relays 36mA (each active relay draws an additional 40mA) Accessories: VISTA-GSM Snap-in Dual-Path Digital Wireless Communicator (IP required for activation and registration) 4286 VIP Voice Module 220mA 5881ENL RF Receiver supports up to eight zones 60mA 5881ENM supports up to 16 zones 50mA 5881ENH up to 48 zones 50mA 5883H High Security Transceiver Module supports up to 48 zones 80mA Supports Eagle 1225 and 1221 boards Keypads: 6160 Custom Alpha (required for programming) 100mA 6160V Custom Alpha Voice 100mA 6150 Fixed English LCD 85mA/40mA 6150V Fixed English Voice LCD 85mA/40mA 6150RF Fixed English RF LCD 85mA/40mA 6148 Fixed English LCD 70mA/30mA 6270 Graphic Touchscreen User Interface 6271C Color Graphic Touchscreen User Interface 6271CV Color Graphic Touchscreen User Interface with Voice 8132 Symphony Advanced User Interface Agency Listings: ETL listing: Residential Fire and Burglary: Household Fire Warning System Units ANSI/UL 985, 2000/05/26 (5th edition) with revisions up to 2004/04/29 Standard for Safety for Digital Alarm Communicator System Units ANSI/UL 1635, 1996 (3rd edition) Safety of Household Burglar Alarm System Units, ANSI/UL 1023, issued 1996/11/25 (6th edition) with revisions up to 12/30/04 Commercial Burglary:
Standard for Safety for Police Station Connected Burglar Alarm Units
and Systems ANSI/UL 365 (4th edition), issued 1997/01/31 with
revisions up to 2005/03/08 Standard for Safety Local Burglar
Alarm Units and Systems UL 609 (11th edition), issued1996/08/28 with
revisions up to 2005/03/17 Standard for Safety Central Station
Burglar Alarm Units ANSI/UL 1610 (3rd edition), issued 1998/10/26
with revisions up to 2005/08/16 Communications: VISTA-GSM Snap-in Dual-Path Digital Wireless Communicator (IP required for activation and registration) Touchtone or pulse standard TELCO dialers Formats supported: ADEMCO Contact ID ADEMCO 4 + 2 Express ADEMCO low speed Sescoa/Radionics 3 + 1, 4 + 1 and 4 + 2 reporting Reporting capabilities: Split, Dual, Split/Dual, True dial tone detection Low battery reports: 11.2 11.6VDC AC loss and restoral reporting supported
The 6160 Deluxe Keypad is easy to install and simple to use. The
attractive white console blends with any d้cor and features a
contoured, removable door that conceals illuminated soft-touch keys.
The 6160 also features a new larger and brighter 32-character display
with easy-to-read plain-English status messages. The oversized
function keys are easily accessed even when the keypad door is closed,
and can be programmed for fire, burglary, personal emergencies and
other operations. Colored self-adhesive labels are included. Features - Large, easy-to-use keypad
- Keys continuously backlit for greater visibility
- Speaker with audible beeps to indicate:
- System status - Entry/exit delay - Other alarm situations - Zones and system events displayed in plain English
- No confusing blinking lights
- Four programmable function keys
- System functions clearly labeled
- Functions performed by just entering security code plus command
- White with removable door blends with any d้cor
|
|
 |
 |
 |
 |
|
 |

|