The HVBMAXPTZPIT Protocol Interface Translator (PIT) converts Honeywell's Maxpro serial command protocol to Honeywell’s VCL and Diamond Maxpro mode and Sensormatic’s (AD) PTZ protocol. The PIT has two serial communications ports. The RS422/RS485 "Slave" port connects to the master controller outputting MAXPRO-Net protocol. An RS232 to RS422 converter is required between the MAXPRO-Net controller and the PIT to convert the MAXPRO-Net data from RS232 to RS422. The RS422/RS485 "Master" port connects to the PTZ devices.
On power up, both the slave channel and the master channel LEDs will be illuminated. The PIT unit receives serial messages from the MAXPRO-NET controller, via its slave communication port. When a valid message is received, the slave port LED will flash off briefly to indicate message receipt. Only messages addressed to the unit address set up on DIP switch 2 will be received. Should DIP switch 2 be set to zero (all switches off), then messages addressed to any PTZ unit will be received by the PIT. The received PTZ control message will then be translated into the appropriate command, compatible with the PTZ equipment selected by means of DIP switch 3. This message will be transmitted out of the master port to one or more PTZ telemetry receivers/domes. When the message is transmitted, the master port LED flashes off briefly. If the PTZ protocol supports addressing, the PIT can be set to address zero (broadcast mode) and each PTZ unit on the master communication port set to a unique address. There is no limitation in mixing PTZ units/domes as long as the above requirements are met and there is at least one PIT per translation type. Should an installation require one or more PIT units for protocol translation, this has no effect on the connection/operation of standard PTZ units, which are compatible with the "native" RS422 protocol generated by the master controller. The PIT takes care of translating fixed speed commands into variable speed commands, which are automatically ramped from slow to high speed, when the PTZ unit supports variable speed.
- Power Requirements: 10-28V dc or 9-20V ac; 3VA without external load 500mA Fuse
Mechanical Dimensions: 2.91” (W) x 1.23” (H) x 7.52” (D) [74mm (W)X31.2 mm (H) X 190.9mm (D)] Weight: 14 oz. (390g) Finish: Brushed stainless steel Environmental Operating Temperature: 14 to 122 degree F)-10 to +50degree C) Storage Temperature: -4 to 149 degree F (-20 to +65degree C) Humidity: 0 to 95% RH (non-condensing) Slave Communications Port Baud Rate: 9600 Baud, 19.2K Baud, 57.6K baud or 115.2K baud. Addressing range: Broadcast or 1 to 255 Protocol: MAXPRO-Net Electrical: RS422, can be wired for RS485. Master Communications Port Baud Rate: From 1200 Baud to 57.6K baud, dependent on required translation type. Protocol: Honeywell VCL (HD6), Honeywell Maxpro (HD6), or Sensormatic (AD) Electrical: RS422, can be wired for RS485. Connector Type RS422 D9 Female Power 2.0mm DC plug I2C 6 position RJ45 (4 fitted) Functions Pan, tilt, zoom, focus, iris, 64 position presets store and recall, auxiliary function control.Functions not available on selected translation target device are excluded. Other: Switch selectable write protection of preset home position. Auto homing selectable, off, 15sec, 1min or 3min 45sec.
|
|
 |
 |
 |
 |
|
 |

|