You are here: Home > Burglar Alarms / Intrusion >

Sensors for Burglar Alarm Systems

> Life Safety Devices
We found 217 results matching your criteria.
Life Safety Devices
Sort By:
Page of 19
Linear DXS-73 Supervised Photoelectric Smoke Detector Transmitter SDI CHEK06-024 CHEKKIT Smoke Detector Tester NonFlammable 1.4oz
REPLACES LN-DXS72

DXS-73 Supervised Photoelectric Smoke Detector Transmitter

Product Number: SST00113

The Model DXS-73 Supervised Photoelectric Smoke Detector Transmitter is a photoelectric smoke alarm with a built-in transmitter designed for use with Linears DXS and DX Format receivers. When smoke is detected, the alarm sounds a loud local alarm. Twenty seconds after the local alarm sounds, the built-in transmitter sends a digitally coded wireless signal to its companion receiver. The wireless signal will be repeated every 20 seconds as long as smoke is still present.

The digital DXS code format features over a million possible codes. The DXS transmitters are precoded at the factory to unique codes, so no field coding is required. The DXS-73 can send three different codes: alarm, test and low battery status.

The unit is powered by a 3-volt lithium battery. The battery is supplied with the transmitter and can power the unit for up to five years. During normal operation, the green status indicator will blink every 10 seconds. Every hour, the DXS-73 will send a status transmission to the receiver. The hourly signal updates the receiver to the transmitters condition. By monitoring status transmissions, the receiver can determine if a transmitter has a low battery or has been removed from the system. If the battery voltage drops below a preset level the alarm will sound low battery beeps, the red indicator will blink every 45 seconds, and a low battery signal will be sent to the receiver with status reports (some receivers can report low battery status, others cannot).

Features

  • Photoelectric-type detector
  • Alarm, status, and low battery transmissions
  • One 3-volt lithium battery supplied
  • Two status indicators
  • Built-in 85 dBA sounder
  • UL, CSFM and MEA listed
  • DXS format
  • RF frequency: 315 MHz
  • 5.375" W x 5.375" H x 2.25" D

    Models compatible with the DXS-73: These models are COMPATIBLE with product number: SST00113


    PERS-2400A Personal Emergency Reporting System
    DUAL-824 24-channel, 8-loop Supervised Wireless/Hardwire Security Panel
    PERS-3600 Personal Emergency Reporting System
    DXSR-1504 Supervised 4-Channel Receiver
    DXSR-1508 Supervised 8-Channel Receiver
    DVS-1200 12-channel Supervised Wireless Security Console
    DVS-2400 24-channel Supervised Wireless Security Console DXR-702 2-Channel Receiver

  • HAZMAT:ORM-D, GRND SHIP ONLY.

    CHEKKIT SMOKE is a hand-held functional tester of ionisation and photoelectric smoke detectors. A quick one second spray from floor level provides a safe, reliable and economical method of testing.


  • UL listed and Detector manufacturer endorsed formula
  • LOWEST COST PER TEST
  • FASTEST CLEARING TIME
  • Non-Flammable
  • Non-toxic
  • NO PHTHALATE ESTERS
  • No Silicon content
  • Ozone Friendly with no CFCs
  • SENSOR SAFE - does NOT DAMAGE PLASTIC CASING OR INTERNAL CIRCUITRY
  • Most widely used detector tester formula in the world
  • Designed and manufactured by worlds genuine market leader
  • SDI Chekkit CK6 Smoke Detector Tester (6oz) SDI CHEKKIT Smoke Detector Tester NonFlammable 1.4oz MINI SMOKE CASE OF 72  2S-CKMINI

    HAZMAT:ORM-D, GRND SHIP ONLY.

    Chekkit CK6 Smoke Detector Tester (6oz)

    HAZMAT:ORM-D, GRND SHIP ONLY.

    CHEKKIT SMOKE is a hand-held functional tester of ionisation and photoelectric smoke detectors. A quick one second spray from floor level provides a safe, reliable and economical method of testing.


  • UL listed and Detector manufacturer endorsed formula
  • LOWEST COST PER TEST
  • FASTEST CLEARING TIME
  • Non-Flammable
  • Non-toxic
  • NO PHTHALATE ESTERS
  • No Silicon content
  • Ozone Friendly with no CFCs
  • SENSOR SAFE - does NOT DAMAGE PLASTIC CASING OR INTERNAL CIRCUITRY
  • Most widely used detector tester formula in the world
  • Designed and manufactured by worlds genuine market leader
  • SDi SOLO A4 - Smoke Detector Tester (10oz) SDi SOLO330 - FUNCTIONALITY SMOKE DETECTOR TESTER

    SDi SOLO A4 - Smoke Detector Tester (10oz) 2S-SOLOA4AER


    List Price: $19.99

    Our Price : $16.65

    You save $3.34!

    SoloA4 Smoke Detector Tester

    • UL / ULC Listed
    • Detector manufacturer approved
    • Non-flammable
    • Fastest activation
    • Fastest clearing time
    • Non-toxic
    • No harmful residue
    • Silicone free
    • MSDS
    • Code Requirements

     

  • For use with Solo A4 and C3
  • Controlled delivery prevents particle and residue build up
  • Universal suitable for all detectors
  • Detector manufacturer approved
  • UL Listed
  • Silent Knight SD500-SDM Two-wire Smoke Detector Module (Used with the 5820XL Only) Silent Knight SD505-AIS Addressable Ionization Smoke Detector (Used with the 5820XL and 5808 Only)

    Model SD500-SDM Smoke Detector Module

    Requires IntelliKnight Version 6.0

    The IntelliKnight can handle new and retrofit installations with ease with the model SD500-SDM.

    The SD500-SDM allows you to assign an address to a loop of conventional detection devices. These devices can be dry contacts such as pull stations and heat detectors, or 2-wire smoke detectors. This means you can retrofit an existing building and utilize existing conventional devices. The SD500-SDM uses a 24VDC auxiliary power input to power the conventional loop, and is connected to the SLC loop via two wires. The conventional loop can be configured as Class A or Class B giving you the flexibility to handle any job.

     Downloads:

    SD500-SDM Two Wire Smoke Module Spec Sheet (65K PDF file)

    Model SD505-AIS Addressable Ionization Type Smoke Detector

    The SD505-AIS has responsive, yet high operational stability for an extremely wide range of uses. The SD505-AIS can be used in areas where early warning of trouble from super-heated or flaming combustibles is expected.

    The detector features automatic compensation for contamination and a simple detector sensitivity test procedure that can be run from the panel or remotely (using the IntelliKnight 5590 or 5595 software with a Windows TM based computer).

    Operation
    The SD505-AIS ionization smoke detector has two chambers: a sampling chamber and a reference chamber. Smoke or invisible combustion gases can freely penetrate the sampling chamber, but the reference chamber is virtually closed to prevent easy entry. With both chambers ionized by a single radioactive source, a very small current flows. Presence of visible smoke or invisible gases greatly influences the current flow in the sampling chamber, changing the voltage ratio between the chambers. This difference is amplified inside the detector. After reaching the critical level, the detector triggers into alarm.

    The SD505-AIS includes a status LED which blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The status LED lights continuously during the alarm period.

    Features

    • Low profile, 2.25 inches, including base
    • Simple and reliable addressing without mechanical switches
    • Automatic compensation for sensor contamination
    • Built-in fire test feature
    • Simple detector sensitivity testing through the control panel or remotely through a Windows based computer. (5590 or 5595 software required for remote testing.)
    • Adjustable sensitivity
    • Vandal-resistant locking feature
    • Field cleanable

    Specifications

    Radioactive Source: AM-241 .098mCi

    Operating Voltage: 17-41 VDC

    Current Consumption:
    Standby:
    .55 mA
    Alarm: .55 mA

    Ambient Temperature: 32F to 122F (0C to 50C)

    Mounting: 4 SQR, 4 OCT, Single gang mud ring

    Downloads:

    Silent Knight SD505-APS Addressable Photoelectric Smoke Detector Silent Knight SD505-DUCT Addressable Duct Smoke Detector & Housing

    Model SD505-APS Addressable Photoelectric Type Smoke Detector

    The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible smoke particles.

    The detector features automatic compensation for contamination and a simple detector sensitivity test procedure that can be run from the panel or remotely (using the IntelliKnight 5590 or 5595 software with a Windows TM based computer).

    Operation
    The SD505-APS unit is made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event of fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period.

    Features

    • Low profile, 2 inches, including base
    • Simple and reliable addressing without mechanical switches
    • Automatic compensation for sensor contamination
    • Built-in fire test feature
    • Simple detector sensitivity testing through the control panel or remotely through a Windows- based computer. (5590 or 5595 software required for remote testing.)
    • Adjustable sensitivity
    • Vandal-resistance locking features
    • Field cleanable

    Specifications

    Operating Voltage: 17-41 VDC

    Current Consumption:
    Standby: .55 mA
    Alarm: .55 mA

    Ambient Temperature: 32F to 122F, (0C to 50C)

    Mounting: 4 SQR, 4 OCT, Single gang mud ring

     

    Downloads:

    SD505-DUCT Addressable Duct Smoke Detector & Housing

    The SD505DUCT addressable duct smoke detector including the SD505-APS Photoelectric Smoke Sensor is used for detecting smoke and products of combustion present in air moving through HVAC air handling system. When smoke is detected in a duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. Now there's even more power and flexibility available to the IntelliKnight family of products!

    Ademco / Honeywell V128FB-PAK10 - V128FB-24 24-VOLT  FIRE/BURGLARY 128 ZONE COMMERCIAL CONTROL  + 6160CR  KEYPAD, ALPHA, FIRE, RED  + 5140DLM  SUPERVISED DIALER (FOR 5140XM)  + 5192SD  ADDRESSABLE P/E SMOKE DETECTOR - V128FBPAK10 Ademco 5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor
    KIT CONSISTS OF:
  • V128FB-24 24-VOLT FIRE/BURGLARY 128 ZONE COMMERCIAL CONTROL
  • 6160CR KEYPAD ,ALPHA, FIRE, RED
  • 5140DLM SUPERVISED DIALER (FOR 5140XM)
  • 5192SD ADDRESSABLE P/E SMOKE DETECTOR

    Commercial Fire and Partitioned Burglary Alarm Control Panel

    Designed to integrate seamlessly with CCTV, access control, and ADEMCOs full range of fire and burglary components, the NEW VISTA-128FBP provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions, and supports up to 128 zones/points using hardwired, wireless and V-Plex addressable technologies. A diverse line of ADEMCO initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays are supported by extremely powerful control platform. The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. A revolutionary new feature called Panel Linking allows multiple partitions, panels - even buildings to be armed, disarmed and have status checked from one location.

    FEATURES
    • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones
    • Can control eight separate areas independently (8 partitions)
    • Supports Panel-Linking allows up to 8 systems or buildings to be controlled from one central location (using VA8200)
    • Supports commercial UL wireless fire and burg
    • Stores up to 512 events and can accommodate 150 user codes
    • Supports addressable V-Plex access control points using VistaKey (1 to 8 doors)
    • Supports up to 16 doors of access control using Vista Gateway Module (VGM)*
    • Supports CCTV applications with the new VistaView-100 CCTV Switcher Module
    • Identifies the point or zone of a fire or alarm, using the new FSA-8/FSA-24 Fire System Annunciator
    • Programmable to meet SIA false alarm prevention specifications. To meet UL approval forANSI/SIA CP-01-2000 order part number VISTA-128SIA
    • Two on-board notification (bell) circuits delivering 2.3 amp @ 12V or 3.4 amp @ 24V
    • Automatic smoke detector sensitivity maintenance testing
    • 4-wire smoke reset using onboard J2 output trigger
    • Supports Dynamic Signaling for LRR
    • Supports Remote Control-via the internet**
    • Supports Internet Alarm Reporting**
    • Supports the new Graphical User Interface Consoles
    • Supports up to 250 access card holders using VistaKey
    • Supports AlphaNumeric pager up to 8 different numbers using the VA8201
    * Connects to Northern Computers Passpoint Access Control Systems. Maximum 32 doors.

    ** When used with AlarmNet-i

    ADDITIONAL FEATURES

    • Notification Appliance Circuits (two):
      - Programmable
      - Temporal code compliant
      - Individually silenceable
    • Programmable on-board auxiliary relay
    • SIA false alarm reduction features:
      - Exit error logic
      - Exit delay reset
      - Cross zoning
      - Call waiting defeat
      - Recent close report
    • Supports commercial hardwired, addressable V-Plex polling loop and wireless zones
    • Hardwired zones
      - Provides eight style B hardwired zones
      - EOLR supervised for Fire and UL burglary installations
      - Supports N.O or N.C. sensors
      - Individually assignable to any eight partition
      - Up to 32 two-wire smoke detectors each on zone one and two (64 total)
      - Up to 50 two-wire glassbreak detectors on zone eight
    • Patented addressable V-Plex polling loop technology
      - Supports 120 two-wire zones points
      - Global polling technology for faster processing
      - Increased current draw capacity (128mA)
      - Supervised by panel
      - Individually assignable to partitions, notification circuit (bell) output or aux relay
      - 4,000 ft capability without the use of shielded cable
      - Extender/Isolation bus module
      - Two-wire smoke detector zone/group expansion module adds two or four zones
      - Eight zone - Class A and B extender module
      - Eight zone - Class B extender module
      - One zone supervised contact monitor module
    • UL Listed wireless expansion
      - Supports up to 128 wireless zones/points using 5881ENHC receiver
      - Supervised by control for check-in signals
      - Tamper protection for transmitters
      - Individually assignable up to eight partitions
      - Supports UL864/NFPA approved wireless smoke detectors
    • Access Control integration
      - Full integration with PassPoint Access Control System Complete Gateway interface of VISTA and access functions
    • Up to 8 doors using VistaKey V-Plex Access Control
    • Event reporting
    • Local printer of access or VISTA related event
    • Scheduled uploading of events to central station
    • Stored events for one call retrieval
    • Communication 
      - Phone mapping by zone response type
      - Supports VIP interactive phone voice module
      - Panel operation during download
      - Uploading equipment list to central station
      - Communication to PassPoint via Vista Gateway Module
    • CCTV integration
      - Supports VistaView-100 ECP based CCTV switchers
    APPLICATIONS
    The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments.


    Installation
    The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations.

    CONTROL PANEL SPECIFICATIONS:

    Applications:
    The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments.

    Installation: The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations.

    Electrical Specifications :
  • Primary power: 18VAC @ 72VA Honeywell No. 1451
  • Control panel quiescent current draw: 350mA
  • Backup battery:
    12VDC, 12AH min to 34.4AH max
    Lead acid battery (gel type)
  • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3amps @ 12V
  • Aux. standby pwr: 12VDC, 1Amax
  • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources
  • Standby time: 24 hours with 1A standby load using 34.4AH battery
  • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited.
  • Optional 24-volt power supply, PS 24 Supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputsMain Dialer:
  • Line seize: Double Pole
  • Ringer equiv.: 0.7B
  • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics
  • Dual phone line capability (using 5140DLM module)

    Cabinet dimensions:
  • 18H X 14.5W X 4.3D

    Environmental:
  • Storage temp: 14F to 158F (-10C to 70C)
  • Operating temp: 32F to 122F (0C to 50C)
  • Humidity: 85% RH
  • EMI: Meets or exceeds the following requirements:
    FCC Part 15, Class B Device
    FCC Part 68
    IEC EMC Directive

    Agency Listings Burglary:
  • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault
  • UL611/1610 Grades A, AA, Central Station
  • UL365 Grades A, AA Police Connect

    Fire:
  • UL864/NFPA72 Local, Central Station and Remote Station
  • Factory Mutual
  • California State Fire Marshal
  • MEA
  • UL985

    Auxiliary Devices:
  • 6160CR
    Red Alpha Keypad
  • 6139R
    Red Alpha Keypad/Annunciator
  • FSA-8 & FSA-24 annunciator modules
  • 4204
    Relay Module, four form C contacts
  • 4204CF
    Two supervised output circuits
  • 5881 Series
    RF receiver supporting 5800 wireless detectors
  • 6220S
    System printer used with 4100SM serial module

    Two-wire smoke detectors, conventional:
  • 2100 Series Photoelectric
  • 2400 Series Photoelectric
  • 1100 Series Ionization

    Four-wire smoke detectors, conventional:
  • 2112/24 Series Photoelectric
  • 1412 Series Ionization

    Horn/Strobes:
  • System Sensor Notification Appliances

    Manual Pull Stations:
  • 5140MPS-1
  • 5140MPS-2

    V-Plex (addressable) Devices:
  • 4208U Loop Expansion Module
    eight zones
  • 4101SN Single Relay/Zone Module
  • 4208SNF Class A/B Expander Module
  • 4209U Group Zoning Module
    two/four zones
  • 4190SN Remote Point Module
    two zones
  • 4193SN Two Zone Serial Interface Module
  • 4293SN One Zone Serial Interface Module
  • 4297 Isolation/Extender Module

    V-Plex (addressable) Smoke Detectors:
  • 5192SD
  • 4192SD
  • 4192CP
  • 5192SDT
  • 4192SDT
  • 4192CPM
  • 4192SDTM

    V-Plex Passive Infrared Detectors:
  • 998MX
  • 4275EX-SN
  • 4278EX-SN

    V-Plex (addressable) Contacts:
  • 4939SN-WH
  • 4944SN-WH
  • 4959SN

    V-Plex Glassbreak Detectors:
  • 9500SN

    VISTA interactive phone module:
  • 4286 Voice Module

    Optional 24V Power Supply:
  • PS24
    24V power supply
    3.4A

    Long Range Radio:
  • Long Range Radio 7720ULF-XX, 7835C, 7835CF, 7845C

    Upgraded software:
  • Upgraded Compass Downloader Windows compatible

    Wireless Devices:
  • 5804BDV
    Bi-directional with voice
  • 5804BD
    Bi-directional Key
  • 5804Watch
    Wireless Key & sports watch combined
  • 5816
    Door/Window Transmitter
  • 5804
    Wireless key
  • 5827BD
    Bi-directional Keypad
  • 5890
    PIR
  • 5849
    Glassbreak Detector
  • 5819
    Shock Sensor

    Commercial Wireless Devices:
  • 5808W3
    Photoelectric Smoke/Heat Detector
  • 5809
    Wireless Heat Detector
  • 5817CB
    Wireless Commercial Transmitter
  • 5869
    Hold-Up Transmitter
  • 5881ENHC
    Commercial Fire/Burg Receiver Access Control
  • VistaKey V-Plex (addressable)

    Access Control:
  • VistaKey-SK Starter Kit
  • VistaKey-EX Expansion Kit
  • VGM Vista Gateway Module to PassPoint Access Control (Northern Computers)

    CCTV:
  • VistaView-100 CCTV Switcher or Module

    Alarm Communications:
  • Graphical user interface with Internet capability
  • Internet Remote Control-Networking Module
  • Internet Alarm Communicator (7845i)
  • 7845GSM
    Digital Cellular Communicator
  • 7845i-GSM
    Internet and Digital Cellular Communicator

    Paging:
  • VA8201 AlphaNumeric Pager
  • DISCONTINUED REPLACED BY 5193SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor

    The ADEMCO 5192 Series low profile, addressable V-Plex smoke detectors deliver state-of the-art features and benefits in a cost-effective package. These detectors are designed to provide open area coverage and are compatible with ADEMCOs VISTA controls supporting V-Plex technology.

    An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range.

    An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability - a feature normally found in todays high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions.

    These HIGH and LOW SENSITIVITY signals are communicated back to the control, via the V-Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with Vista-32FB, 128FB, 128B and First Alert Professional FA1600C.

    More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity/viability.

    Moreover. the smoke detectors are able to operate on existing wiring. There's no need to run special twisted pair, data grade or shielded wires. That adds up to valuable savings in time and materials!

    • Low profile design
    • V-Plex addressable loop device
    • Automatic maintenance reporting
    • Available with integral heat sensor
    • Simple 2 wire installation
    • Tamper resistant
    • DIP switch or serial number programmable
    • Lines on existing or conventional wiring
       
     
    Hold Up Buttons & Switches
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please