8 Zone Hybrid Control Expandable To 32 Zones Or 48 Wireless Points, with Transformer
- Operating temperature: 0-49ºC (32-120ºF)
- Input power: 16.5Vac via Class 2 Plug-In 40VA Transformer, supplied
- Loop voltage: 10-13VAC
- Loop current: 2.5mA with 2.2ohm end-of-line resistor (model EOL2.2K); 5mA for 2-wire smoke-detector zones
- Loop resistance: 300W max.; 50W for 2-wire smoke detector zones
- Relay outputs (burglary; reset; aux): wet, 12Vdc, 1.2A max.; dry (cut related jumper for dry contacts), SPDT contacts 24Vdc, 2A, 0:6 PF
- Auxiliary power output: 12 Vdc regulated
- Remote power output: 12Vdc regulated (for keypads) 650 mA combined Standby Current (Remote Power + Aux. Power + Reset Relay Power)
- Standby time: Residential fire/burglary & commercial burglary, 4 hours minimum
- EZM Module: GEM-EZM8: input, 50mA (including PGM Output)
- PGM output: 5mA, 12V special application
- Keypad current: GEM-RP1CAe2, GEM K1CA: 100mA; 35mA if back lighting is disabled (cut W1, W2 & W3)
- PGM output: 5mA, 12V special application
- Maximum number of keypads: 15 maximum wiring length for each run (#22AWG): 1000’ divided by total number of keypads & EZMs on run
- Keypad Dimensions: 4 3/8” x 5 7/8” x 1 1/6” (HWD); 11.1cm x 14.9cm x 2.7cm (HWD)
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- 8 End-of-line-resistor burglary zones programmable for area, exit/entry delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, zone anding and a variety of other features
- Up to 48 points of up to 32 zones with optional zone-expansion modules 4- zone keypad EZMs (built-in)
- Including up to 2 2-wire fire zones
- Up to 32 individually coded users, each with a programmable authority level
- 3 on-board relay outputs, expandable 24 external relay outputs
- 3 keypad panics: fire, police & auxiliary
- 2 independent area partitions
- Up to 7 separate access stations by up to 32 users
- Up to 24 separately-addressable X-10 devices with the GEM-X10KIT
- English-language prompts & system status messages from choice of keypad (8) models
- User-customized zone descriptions, reprogrammable as required
- 2-wire and 4-wire smoke detectors
- Reports alarms, restores and troubles by zone
- 255 event schedule
- 800 event log
- Overview mode permits monitoring and control of total system from one keypad
- 2 programmable entry delay times
- Interior-bypass group
- Dynamic battery test interrupts charging and places battery under load every four hours
- Chime by zone; programmable duration
- Non-volatile RAM retains memory during power losses
- Quickloader™ programmable
- Auto-Download Log
- Exclusive V.A.L.I.D.™ feature (Verifying Automatic Line Integrity Diagnostic) reduces false alarms due to changes in line resistance Communicator features
- Compatible with all major receiver formats, including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4 + 2 Express and Point ID
- Rotary dial and TouchTone™ with Rotary backup
- 3 20-digit telephone numbers
- Backup reporting, double reporting; split reporting
- 32 User codes with opening/closing reporting by user
- AC failure reporting with programmable report delay
- Supervised telephone line cut with programmable delay
- Pager capability
|
|
 |
 |
 |
 |
|
 |

|