The GEM-P1664 Hybrid 8 to 64-Zone Control/Communicator features 8 zones expandable to 64 zones with multiplexing and supports proven, reliable, NAPCO crystal-control transmitters and uses advanced helically-filtered receivers, too. Supporting up to 64 user codes and 8 16 relays, the GEM-P1664 comes in two configurations suitable for EN50131-1 and/or CE installations. This Gem control features easy “Self-Programming Plus” keypad programming (for all zones), which includes new alpha keypad question-prompts, even for setting test timer, fire zones and exit/entry and follower zones. Additionally, the panel can be remote up/downloaded using easy-to-use NAPCO Quickloader Software (V5.0 or greater) with true Windows-style functionality, including cut/paste, drop/drag, etc.
Specifications:
Environmental Classification: Class I (+5C to +40C), Class II (-10C to +40C) and Class III (-25C to +50C) Input power: 16.5VAC via Class 2 plug-in 20VA, 40VA or 50VA transformer Loop voltage: 10-13VDCdc Loop current: 32.5mA with 2.2k ohm EOLR; 5mA for 2-wire fire Loop resistance: 300 ohm max.; 50 ohm max for 2-wire fire Aux & remote power: 12VDC regulated (11.7 to 12.5VDC) Maximum Combined standby current: 650mA Maximum Alarm current: 2A Burg. voltage output: 1 Programmable negative outputs: 2 Loop response 750ms, programmable 50ms to 2,000ms
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- 8 Hardwire/Wireless Zones on board
- Up to 64 zones with multiplex expansion including 2 two 2-wire fire zones
- With multiplexing, can accommodate up to 64 EOL zones (from custom alpha keypads or multiplex modules)
- EZ Programming2 More comprehensive, menu-driven programming for all zones plus test timer.
- Up to 64 user codes
- Up to 4 areas
- 3 on-board outputs, up to16 external relay outputs (RM3008s).
- Up to 2 NAPCO helically-filtered, crystalcontrol RF receivers
- Interior bypass group with programmable automatic interior bypass
- 600 event log
- Auto Arm
- Uses up to 7 of any of the Classic/RP- or KSeries Stay & Away keypads
- Programmable telephone line cut supervision with delay
- 3 Keypad panics (F, P, A)
- Supports all major communicator formats, including: 4/2, SIA, 4+2 and Point ID, plus pager
- Backup/double/split reporting; three 20-digit telephone numbers
- Dynamic battery test
- Reports alarms, restores and troubles by zone.
- 2 programmable entry delay times
- Chime by zone
- 8 EOL burglary zones programmable for area, E/E delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, cross zoning , etc.
- Supports series zone doubling and Loop supervision using double EOL resistors (feature requires use of GEM-EZM4/8 Multiplex Modules)
- Multiplex Expandability with GEM EZM4/8 or GEM EZM8 zone expansion modules
- Quickloader up/downloading, including unique unattended method
- Choice of RF receivers
- Partitioning by area
- Event log with open/close suppression
- Event log viewable at keypad (total log,burglar alarm log, fire alarm log, system trouble log, o/c log)
- Cellphone-style keypad programming of zone descriptions ( text)
- Programmable 50Hz Clock Setting
- Programmable Daylight Savings Time
- Programmable Security Bypass (code required for bypass)
- Un-Bypassing while disarmed (code required)
- Temperature Display at Keypad (-30 to 600C Celsius or -22 to 1400F Fahrenheit) with optional GEM-TEMP64 Indoor/Outdoor Temperature Sensor (Note: Keypad Temperature Display replaces Date on Display)
- Programmable High/Low Temperature Alarm Reporting (requires feature enabled; zone 6)
- 24 Hour day zone trouble
- Programmable security blocking of keypad display messages –Informational displays made visible contingent on user’s assigned area(s) within system
- Programmable Swinger Shutdown (2 or 3 activations – selectable)
- Zone Anding/Cross Zoning (Grouping of zones in which sequential zone activation is required to generate an alarm)
|
|
 |
 |
 |
 |
|
 |

|