PFC4410RC Releasing Control Panel PL-PFC4410RC REPLACES PL-PFC4410 & REPLACES PL-PFC2000RC
PFC4410-RC RELEASING CONTROL PANEL DIMENSIONS: 18 1/4" X 14 1/4" X 4 3/4"g
UL Listed, FM Approved, NYMEA Accepted, CSFM Approved
PFC-4410-RC Water OR Agent Extinguishing Panel - Potter Electric Signal Company announces the release of our new PFC-4410-RC Releasing Panel. Our Water OR Chemical based extinguishing panel includes 4 Class B programmable initiating zones, 4 programmable Class B outputs, and 20 pre-configured programs. This single or dual hazard panel is also compatible with 3500 feet of Linear Heat Detection per zone. The new, innovative technology of the PFC-4410-RC allows you to use the same panel to control water OR chemical discharge. The PFC-4410-RC is UL, CSFM, NYMEA Listed, and FM approved.
The Potter Model PFC-4410-RC is a microprocessor based multihazard releasing control panel for use on pre-action and deluge type sprinkler systems as well as chemical extinguishing systems. The model PFC-4410-RC is Underwriters Laboratories Listed and complies with UL Standard 864 for Local Control Units for Releasing Service. It is designed to be compatible with the requirements of: NFPA-12, NFPA-12A, NFPA-13, NFPA-15, NFPA-16, NFPA-17, NFPA-17A, NFPA-72, NFPA-750, and NFPA-2001.
The PFC-4410-RC is housed in a steel cabinet with removable door and key lock. Standard fi nish is off-white with gray and red trim. Red cabinets with black and white trim are also available. A matching bezel is available as an option for semi-fl ush mounting in a wall. The cabinet will house up to a 12AH standby battery which is capable of powering the unit in excess of 90 hours.
Features:
Multi-Hazard Operation
Supervised Microprocessor
32 Character Alpha-Numeric LCD Display
Custom Banner Message Text
Custom Zone Description Text
On Board Menu Driven Programming Controls
Releasing Circuits Protected From False Activation
Four Class B Initiating Circuits
One Class B Supervisory Circuit
Four Class B Output Circuits
Programmable Cross Zoning
Continuous or Timed Discharge
40 Event History Buffer
Walktest with Automatic Time-out
Alarm, Trouble and Supervisory Relays
Optional Class A Initiating Zone Module
Optional Class A Output Zone Module
19 Standard Programs in Panel Memory
Password Protection for all Programming
24 Hour Clock
Supervised Remote annunciator output
Suitable for chemical or waterbased extinguishing
Programmable 0-60 second pre-discharge timer*
Programmable 0-30 second manual release pre-discharge timer*
One Class B Abort circuit*
Three Abort modes*
* Available in Chemical mode only