Home > Shop Brands > Silent Knight by Honeywell >

  Silent Knight SK-5824 Printer Interface Module Serial/Parallel

Silent Knight SK-5824 Printer Interface Module Serial/Parallel


 

Our Price : $224.32


Product Code: SK-5824

Qty:

Description
 
With one parallel and one RS-232 serial port, the 5824 Serial/Parallel Interface allows you to connect virtually any standard PC-compatible printer to the IntelliKnight system and to generate reports on-site. You can print a log of real-time events and generate user-friendly reports of event history and detector status. And, because a system can have multiple 5824s, you can locate printers strategically within the installation.

The 5824 also provides the Gateway interface for communicating to other systems, such as a building control system. The Gateway protocol is a data stream produced by the FACP that can be used to display system events on a PC monitor. The protocol allows a building control system to handle events and to silence or reset the FACP.

The 5824 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6,000 feet from the panel

The 5824 has one parallel port and one RS-232 serial port for compatibility with most printers. Two 5824 interfaces can be used with the system, and each can be located as far as 6,000 feet from the IntelliKnight panel, allowing for flexibility in locating printers and accessing data.

The 5824 Gateway protocol allows for interface with other systems, such as building control systems.

Engineering Specifications:

The serial/parallel gateway module must be compatible with a IntelliKnight fire alarm control panel and with any standard PC-compatible printer such as the type normally connected to a computer. The FACP must support up to eight 5824 gateway modules.

The unit shall contain two ports, one parallel and one RS-232 serial and must allow for printing the following types of IntelliKnight system data reports: event log, event history, and detector status. The unit shall use a Gateway protocol that allows for communication with other systems, such as building control software.

Specifications:

Operating Voltage: 24 VDC
Current (Alarm and Standby): 50 mA
Max Per FACP Addressable FACPs: 8; 5208 FACP: 1
Ambient Temperature: 32F to 120F (0C to 49C)
Max Wiring Distance from FACP: 6000 ft. (1829 m)
Mounting: Surface
Dimensions: 6"W x 7-3/4"H x 1-7/16"D (15.2 cm W x 19.7 cm H x 3.7 cm D)
Parallel Port: Ancillary
Serial Port: Primary Fire Signaling
Features
  • Allows connection of standard computer printers.
  • Gateway protocol provides interface with building control programs.
  • Displays events on a PC monitor
  • Quick and easy to install.
  • DIP switches for setting ID codes
  • Prints detector status reports.
  • Housed in a sturdy, wall-mountable, plastic enclosure.
  • Out of paper/system trouble annunciated at fire panel.
  • Parallel and RS-232 serial output
  • Date, time, and event in userfriendly report format.
  • UL listed, complies with NFPA 72 and 101
  • UL listed with the Okidata Microline 320 parallel printer.
  • FM approved