Specifications
The SK-Beam and SK-Beam-T are addressable beam smoke detectors for use with IntelliKnight series fire alarm control panels (FACPs). They are uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. The SK-Beam-T also includes an integrated sensitivity test feature.
The SK-Beam and SK-Beam-T are addressable beam smoke detectors for use with Silent Knight Intelliknight series fire alarm control panels (FACPs). The SK-Beam-T also includes an integrated sensitivity test feature.
Installation of the single-ended reflective design is much easier than dual ended projected beam detectors. Alignment is quickly accomplished using an optical sight and a two-digit signal strength meter incorporated into the SK-Beam and
SK-Beam-T.
Listed for operation from -22ºF to 131ºF (-30ºC to 55ºC), the SKBeam and SK-Beam-T can be used in applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detectors.
The SK-Beam and SK-Beam-T consist of transmitter/receiver unit and one reflector. When smoke enters the area between the unit and the reflector it causes a reduction in the signal. When the smoke level reaches the predetermined threshold, the detector generates an alarm signal.
These beam smoke detectors have four sensitivity selections along with two Acclimate settings. When either of the two Acclimate settings are selected, the detector will automatically adjust its sensitivity using advanced software algorithms to select the optimum sensitivity for the specific environment.
The SK-Beam-T is equipped with an integral sensitivity test feature that consists of a test filter attached to a servo motor inside the detector optics. Using the remote test station, System Sensor PN RTS151, the motor is activated and moves the filter in the pathway of the light beam, which tests the detector sensitivity. This integral sensitivity test feature allows the user to quickly and easily meet the annual maintenance and maintenance and test requirements of NFPA 72.
Operating
Protection Range: 16’ – 328’ (5 – 100 m)
Adjustment Angle: +/–10º horizontal & vertical (optics move
independent of the unit)
Sensitivity Levels: Level 1–25%; Level 2–30%; Level
3–40%; Level 4–50%; Level 5–30 to 50% ( Acclimate)
Level 6–40 to 50%(Acclimate)
Fault Condition (Trouble): 96% or more obscuration
blockage in alignment mode; improper alignment; selfcompensation
limit reached
Alignment Aid: Optical gunsight; integral signal strength
indication; 2-digit display
LEDs: Normal–flashing green; Yellow–trouble; Red–alarm
Test/Rest Feature: Integral sensitivity test filter (SK-Beam-T
only); sensitivity filter (incremental scale on reflector); local
test switch; local reset switch; remote test and reset switch
(compatible with RTS151 and RTS151KEY test station)
Physical
Detector: 10” H x 7.5” W x 3.3” D
(25.4cm x 19.1cm x 8.4cm)
Reflector for 16’ – 230’: 7.9” H x 9.1” W (20cm x 23cm)
Reflector for Beyond 230’: 15.7” H x 18.1” W (40cm x 46cm)
Shipping Weight: 3.9 lbs (1.77 kg)
Environmental
Operating Temperature: -22ºF – 131ºF (-30ºC – 55ºC)
Humidity: 10% – 93% non-condensing
Electrical
Operating Voltage: 15 – 32 VDC
Standby Current (Avg): 2 mA max
Current During Testing (Avg): 500 mA max
Alarm Current: 8.5 mA max
Fault Current: 4.5 mA max
Alignment Mode Current: 20 mA
Features
16 to 328 foot protection range
Single-ended, reflective design
Remote test station available
User friendly alignment procedure
Six user selectable sensitivity levels
Optional integral NFPA 72 sensitivity test feature
Removable plug-in terminal blocks
Digital display for easy alignment
Built-in automatic gain control compensates for
signal deterioration from dust build-up
Rotary address switches for fast installation
Paintable cover
Share your knowledge of this product with other customers...
Be the first to write a review
CCTV & Video Surveillance ->
Advanced Technology Video - ATV
AG Neovo displays
American Dynamics
APPro Technology Inc.
Bolide
DiGiMERGE
Digital Watchdog
Eastern CCTV
GeoVision
Honeywell Ademco Video
IC RealTime
Ikegami
LTS CCTV
Access Control & Biometrics Systems ->
Accutech
AWID Applied Wireless Identifications
Actuator / Bioaxiss
BioScrypt
GeoVision Access Control
Honeywell Access Control
IEI
Nedap Long Distance Vehicle ID System
RoamAlert Wander Prevention
Watchmate Wander Prevention