|
|
|
|
|
|
|
|
|
|
Takex America (Pulnix) HTF24 High Out-put 24VDC Heater for Twin or Quad Beams
|
Fits all Quad Beams
|
|
|
|
|
|
|
|
|
|
|
|
Takex America (Pulnix) BP-220F Back Cover for pole mounting QUADS, 100AT, 100ST (1PAIR)
|
The COM-IN-50HF consists of 4-stacked photoelectric beams and 24.1 GHz microwave which reinforces the unit's range and stability in severe weather conditions. A special anti-frost/dew hood protects the beam even when the cover is screened by inclement weather. When the beam reception level is reduced below an acceptable level by poor weather conditions, an environmental output selector initiates an environmental signal. In addition, a special sensetivity attenuation LED lights up in cases of low sensitivty. Additional Features Alarm memory LED indicated which sensor issues an alarm when two or more sensors are placed on a zone. Photoelectric beam sensor features 4 synchronized high-ower infrared beams. Four frequency selections make it possible to avoid crosstalk between sensors. Specifications 165' Outdoor Combination Intelligent Double Modulated Quad Photoelectric Beam and Microwave sensor, Improved catch performance during difficult weather conditions, Auto Gain control, Environmental Monitoring circuit, 2 frequencies available, Tamper circuit, 12V to 30VDC
|
|
|
|
|
|
|
|
|
|
|
|
Takex America (Pulnix) COMIN50HF 155' Outdoor / 330' Indoor Double Quad Beam, Intelligent Modulator Micro Combo
|
Takex America (Pulnix) HS-02 Heater Strip Kit w/Thermostat, One ended, Large Twin or Quad
|
|
|
|
|
|
|
|
|
|
|
|
Takex America (Pulnix) HS-04 Heater Strip Kit w/Thermostat, One ended, Large Twin or Quad
|
Takex America (Pulnix) HTF24 Heater for Synchro Quad Beam
|
|
|
|
|
|
|
|
|
|
|
|
The PA-7000 Series "Digital-Quad" passive infrared sensors are the newest line of quad elements PIRs. Each unit contains two dual-element sensors which are linked by a digital central rocesing unit. This results in calculation of a true motion signal in order to initiate an alarm. It can detect a human-like pattern definition and reject other potential false alarm causes. Sensetivity of the unit is automatically adjusted relative to the environmental temperature. In addition, the unit contains special circuitry to indicate that it had activated an alarm during its armed period. 50’ x 50’ Wide-Angle Digital Quad, Mirror Optic, On-board pattern locator, Automatic temperature compensation, Form “C” output, Tamper Circuit, Alarm Memory, 9 to 18 VDC, UL Listed Remote control LED EMI Immunity
|
The PA-7000 Series "Digital-Quad" passive infrared sensors are the newest line of quad elements PIRs. Each unit contains two dual-element sensors which are linked by a digital central rocesing unit. This results in calculation of a true motion signal in order to initiate an alarm. It can detect a human-like pattern definition and reject other potential false alarm causes. Sensetivity of the unit is automatically adjusted relative to the environmental temperature. In addition, the unit contains special circuitry to indicate that it had activated an alarm during its armed period. 100’ x 6’ Long RangeDigital Quad, Mirror Optic, On-board pattern locator, Automatic temperature compensation, Form “C” output, Tamper Circuit, Alarm Memory, 9 to 18 VDC, UL Listed Remote control LED EMI Immunity
|
|
|
|
|
|
|
|
|
|
|
|
PA-7100 360° x 40’ diameter when mounted at 12’, Digital Quad, Mirror Optic, On-board pattern locator, Automatic temperature compensation, Form “C” output, Tamper Circuit, Alarm Memory, 9 to 18VDC, UL Listed
|
Takex's PB Series Sensors feature double modulation frequency and phased-locked loop system which result in high-power beams that have 10x the maximum arrival distance and 100x maximum sensetivity. Simultaneous breaking of 4 beams is required to initiate an alarm, thus eliminating the most common causes of false alarms - small animals, falling leaves. Features Anti-external light circuit provides tolerance for sunlight, mercury or fluorescent light. Excellent tolerance for bad weather. Confirm visual and audible beam alignment with Sound Check Function Attentuation LED lights up when beam attenuates under a certain level. AGC Circuit automatically maintains proper sensitivity depending on environmental conditions. Special noise eliminator provides excellent RFI. Special hood protects sensor against inclement weather Specifications Detection System Quad, Active Infrared Beam Wavelength 940nm Modulation Double Pulse Modulation Protection Distance Outdoors 50m (165ft) Protection Distance Indoors 100m (330ft) Signal Arrival Distance 500m (1650) Response Time 50-700msec.
|
|