Honeywells V-Plex addressable technology offers many new innovations while fully supporting our previous generation of addressable loop products.
Honeywell's smoke and heat detectors install quickly and easily. Point identification and maintenance alert capabilities make it easy to identify the detector in alarm and simplify service and maintenance.
Sort By:
Page of 1
Ademco 5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor Honeywell's 5193SD Addressable Photoelectric Smoke Detector
DISCONTINUED REPLACED BY 5193SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor

The ADEMCO 5192 Series low profile, addressable V-Plex smoke detectors deliver state-of the-art features and benefits in a cost-effective package. These detectors are designed to provide open area coverage and are compatible with ADEMCO’s VISTA controls supporting V-Plex technology.

An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range.

An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability - a feature normally found in today’s high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions.

These HIGH and LOW SENSITIVITY signals are communicated back to the control, via the V-Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with Vista-32FB, 128FB, 128B and First Alert Professional FA1600C.

More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity/viability.

Moreover. the smoke detectors are able to operate on existing wiring. There's no need to run special twisted pair, data grade or shielded wires. That adds up to valuable savings in time and materials!

  • Low profile design
  • V-Plex™ addressable loop device
  • Automatic maintenance reporting
  • Available with integral heat sensor
  • Simple 2 wire installation
  • Tamper resistant
  • DIP switch or serial number programmable
  • Lines on existing or conventional wiring
Honeywell's 5193SD / 5193SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL-listed Honeywell control panels that support V-Plex technology. The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit's chamber. The 5193SDT also features a restorable, built-in, fixed temperature (135° F/57.2° C) thermal detector.
Honeywell's 5193SDT Addressable Photoelectric Smoke Detector
Honeywell's 5193SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL-listed Honeywell control panels that support V-Plex technology. The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit's chamber. The 5193SDT also features a restorable, built-in, fixed temperature (135° F/57.2° C) thermal detector.
   
 
 
 

Enter your email for a chance to WIN $100 Amex Gift Card.

Please Enter Your Email Address

*One entry per household please