These listed strobes have been designed for use in potentially explosive atmospheres and harsh environmental conditions. The enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance is required. The housings are manufactured completely from a U.V. stable, glass reinforced polyester. Stainless steel screws and mounting bracket are available ensuring a totally corrosionfree product. The model XB15 contains a polarization diode and four wire lead connections for fire alarm applications. Units can be painted to customer specification and supplied with identification labels.
Specifications:
Certification: UL Listed for USA and Canada:
Hazardous locations:
Class I, Div 2, groups A, B, C & D. Class 1, Zone 1 Class II, Div 2, groups F & G, AExd IIC T4/T5
UL listing No. E187894 Ordinary locations: Visual Signal Device, Marine Listed UL listing No. S8128 CENELEC EN50014 & EN50018 ATEX Cert. No. Baseefa 04ATEX0009X
Material:
Body: Glass reinforced polyester Lens: Glass Backstrap: stainless steel 316 Wire Guard (optional): Stainless steel wire Cast Guard (optional): Aluminium LM25M Finish: Natural black or epoxy painted to customer specification Voltage: 24, 48V d.c. 110, 120, 230, 240, 254V a.c Tube Energy: 15 Joules Tube Life: >1 x 6 power of 10 flashes Flash Rate: 60, 80, 120 fpm Certified: -67°F to +104°F (T6) -55°C to +40°C (T6) Temperature: -67°F to +131°F (T5) -55°C to +55°C (T5) Weight: Pipe mount: 5.75lb./2.6kg; Direct mount: 6.5lb./3.0kg Ingress: NEMA 4x &6, IP66 & IP67
Entries:
Supplied as 2 x 3/4" NPT (direct mount) or 3/4" (pipe mount) as standard
Other options available:
Up to 3 x 1/2" NPT or 3 x 3/4" NPT (direct mount) 1/2" NPT (pipe mount) - contact sales office to order
Terminals:
Direct mount: 12 x 14 AWG Pipe mount: 8 x 14 AWG
Relay Initiate: Available on all units - suitable for 24V d.c. supplies only Labels: Tag/Duty label option
Electrical Ratings:
Voltage: 120 Current (A): .4
Effective Candela: 330
Multiplying Factor for Colored Lenses:
Red: 0.15
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- UL listed for USA and Canada
- Hazardous locations:
- Class I, Div. 2, Groups A, B, C & D.
- Class I, Zone 1, AExd IIC T5/T6
- Class II, Div. 2, Groups F & G
- Ordinary locations: Visual-Signal Device
- Marine Listed
- CSFM Listed
- ULC Listed to Canadian Safety Standards
- Conforms to ULC regulated a.c. power supplies
- ATEX approved
- NEMA 4x & 6, IP66 & 67
- Certified temperature -67°F to +158°F (-55°C to +70°C)
- 520,000 peak candlepower
- Pipe mount or direct mount enclosure
- Corrosion-free GRP
- Four wire monitored connection and supervisory Diode
- Optional stainless steel backstrap (direct mount version only)
- Various lens colors
- Optional relay initiate
- Optional cast or wire lens guard
- Up to 3 x 3/4" NPT entries
- Filament version available (100W max)
|
|
 |
 |
 |
 |
|
 |

|