17003 Key for Control Panel Lock & Pull Station BG8
|
17007 SPARE WRENCH 9/64" (BG10)
|
|
|
|
|
|
|
|
|
|
|
|
WP-10 Outdoor use backbox.
|
The Fire-Watch 411 Series from Fire•Lite are compact, multifaceted, slave Digital Alarm Communicator Transmitters (DACTs) designed for a variety of fire, and non-fire applications. The series consists of two models: the 411 and 411UD, providing three and four monitoring channels (inputs) respectively. These slave DACTs are a cost-effective solution for applications that require an existing (or new) Fire Alarm Control Panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. Due to extremely flexible programming options, the 411 Series slave DACTs are also ideal for monitoring non-fire control panels. With fifteen selectable transmission formats, including ADEMCO Contact ID, compatibility with virtually all Digital Alarm Communicator Receivers (DACR) is ensured. Programming can be accomplished on-site with a hand-held programmer (PRO-411), or remotely (411UD only) utilizing an optional PK-411UD Windows®-based remote upload/download software package. The PK-411UD upload/download software also permits system integration and revision from a remote site.
|
|
|
|
|
|
|
|
|
|
|
|
The Fire-Watch 411 Series from Fire•Lite are compact, multifaceted, slave Digital Alarm Communicator Transmitters (DACTs) designed for a variety of fire, and non-fire applications. The series consists of two models: the 411 and 411UD, providing three and four monitoring channels (inputs) respectively. These slave DACTs are a cost-effective solution for applications that require an existing (or new) Fire Alarm Control Panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. Due to extremely flexible programming options, the 411 Series slave DACTs are also ideal for monitoring non-fire control panels. With fifteen selectable transmission formats, including ADEMCO Contact ID, compatibility with virtually all Digital Alarm Communicator Receivers (DACR) is ensured. Programming can be accomplished on-site with a hand-held programmer (PRO-411), or remotely (411UD only) utilizing an optional PK-411UD Windows®-based remote upload/download software package. The PK-411UD upload/download software also permits system integration and revision from a remote site.
|
411UDAC Four-channel, dual-line, stand-alone or slave Fire Alarm Communicator. Includes housing, operating and programming instructions. Use PRO-411 hand-held DACT programmer for local programming; or PK-411UD Windows-based programming software for remote programming and real-time diagnostics. DP-2 Dead-front dress panel, required for Canadian applications. The Fire-Watch 411UDAC from Fire•Lite is a compact, multifaceted, stand-alone or slave Fire Alarm Communicator designed for a variety of fire and non-fire applications. It provides four channels (inputs) that accept waterflow devices, two- and four-wire smoke detectors, pull stations, and other normally-open contact devices. The 41UDAC is a cost-effective solution for applications that require an existing (or new) fire alarm control or non-fire control panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. Due to its extremely flexible programming options, the 411UDAC is also ideal for use as a stand-alone unit to monitor: sprinkler systems for waterflow and supervisory conditions; processes (i.e., water level, gas detection, loss of air flow); and normally-open contact devices. With fifteen selectable transmission formats, including Ademco Contact ID, compatibility with virtually all Digital Alarm Communicator Receivers (DACR) is ensured. Programming can be accomplished on-site with a hand-held programmer (PRO-411), or remotely utilizing an optional PK-411UD Windows®-based remote upload/download software package. The PK-411UD upload/download software also permits system interrogation and revision from a remote site.
|
|
|
|
|
|
|
|
|
|
|
|
4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5.
|
ABS-8RF Annunciator surface-mount backbox with blank faceplate.
|
|
|
|
|
|
|
|
|
|
|
|
ACC-AAM25 • 25 watt, 25 VRMS audio amplifier module. • Field-programmable for system expansion to 50 watts or as a backup to the primary 25 watt amplifier where required. • Provides single Class A or Class B speaker circuit. • Utilizes plug-in-style terminal blocks for ease of service and maintenance. • Fully supervised and power-limited. • Diagnostic LEDs include: yellow “trouble” LED (cable fault, amp fault) and green “amp functional” LED.
|
ACC-EPM • Provides interface to non-fire paging equipment for nonemergency paging applications. • Provides plug-in-style terminal blocks for ease of service and maintenance. • Transformer-isolated, 600-ohm audio connection to paging equipment. • Electrically-isolated, contact-closure trigger input for activation by the paging equipment.
|
|
|
|
|
|
|
|
|
|
|
|
ACC-TR: Trim Ring, semi-flush mounting.
|
FireLite ACCZSM Zone Splitter Module (ACC-ZSM) divides the output of the Audio Amplifier Module(s) (ACC-AAM25) into up to eight speaker circuits (i.e., zones).
|
|