GE ESL  702E-10PK - 4" Universal Mounting Base 700 Series 10/Pack, 4" Universal Mounting Base With 6 Terminals For All Heads GE ESL 211 - Replaceable Optical Chambers For Esl Smoke Detectors 10/Pack, For Esl 300, 400, 500, 500N, 700 And Ts7 Smokes
The 700 series mounting bases are specifically designed for the demands of commercial and industrial environments. The common, removable and interchangeable head and base design of the 700 series makes each sensor easy to install and maintain. Each detector head simply twists off its universal 4- or 6-inch base for fast cleaning or replacement.
Options include 6- and 4-inch bases with three or six terminals that can be used with all heads or with heads that have relays.
Remote LED indicators for the 700 series are also available.
GE Security offers a 10 pack of Replaceable Optical Chambers For Esl Smoke Detectors
GE ESL 211 - Replaceable Optical Chambers For Esl Smoke Detectors 10/Pack, For Esl 300, 400, 500, 500N, 700 And Ts7 Smokes GE ESL TS7-2 - 2-Wire Photoelectric Smoke Detector, 12/24 Vdc. S10A Compatible, 711U Head With 701U Base
GE Security offers a 10 pack of Replaceable Optical Chambers For Esl Smoke Detectors

The TS7 Series features photoelectric smoke detectors with an easy to install and maintain head and base design.The TS7 smoke detector heads meet NFPA 72 field sensitivity testing requirements withut the need for external meters.

The photoelectric smoke detector heads are self diagnostic and have field replacable optical chambers. They feature automatic drift compensation which adjusts the alarm sensitivity when the detector gets dirty.

The TS7-2 combines a 711U 2-wire, photoelectric sensor and a 701U 6" base.

Standard Features

  • Two or four wire head and base models
  • Intelligent, self-diagnostic
  • Built-in drift compensation
  • Field replaceable opical chamber
  • Low-profile design

    The TS7 Series also features standard features of 500N Series:

  • Built-in sounder available in two- and four-wire models
  • Patented CleanMeŽ feature
  • Built-in dust compensation
  • Field-replaceable optical chamber
  • GE ESL TS7-2R - 2-Wire Photoelectric Smoke Detector W/Auxiliary Relay, 12/24 Vdc. Form C Auxiliary Relay. S11A Compatible, 731U With 702U Base GE ESL TS7-2T - 2-Wire Photoelectric Smoke Detector, W/Remote Alarm/Trouble LED, and Heat Sensors, 12/24 VDC, Remote Alarm/Trouble, S10A Compatible, 721UT w/ 702U Base

    The TS7 Series features photoelectric smoke detectors with an easy to install and maintain head and base design. The TS7 smoke detector heads meet NFPA 72 field sensitivity testing requirements withut the need for external meters.

    The photoelectric smoke detector heads are self diagnostic and have field replacable optical chambers. They feature automatic drift compensation which adjusts the alarm sensitivity when the detector gets dirty.

    The TS7-2R combines a 731U 2-wire photoelectric sensor, Form C relay, and a 702U 6" base.

    Standard Features

  • Two or four wire head and base models
  • Intelligent, self-diagnostic
  • Built-in drift compensation
  • Field replaceable opical chamber
  • Low-profile design

    The TS7 Series also features standard features of 500N Series:

  • Built-in sounder available in two- and four-wire models
  • Patented CleanMeŽ feature
  • Built-in dust compensation
  • Field-replaceable optical chamber
  • The TS7 Series features photoelectric smoke detectors with an easy to install and maintain head and base design. The TS7 smoke detector heads meet NFPA 72 field sensitivity testing requirements withut the need for external meters.

    The photoelectric smoke detector heads are self diagnostic and have field replacable optical chambers. They feature automatic drift compensation which adjusts the alarm sensitivity when the detector gets dirty.

    The TS7-2T combines a 721UT 2-wire photoelectric sensor with rate-of-rise and fixed heat sensors for quick detection of both flaming and smoldering fires, a remote alarm trouble LED, and a 702U 6" base.

    Standard Features

  • Two or four wire head and base models
  • Intelligent, self-diagnostic
  • Built-in drift compensation
  • Field replaceable opical chamber
  • Low-profile design

    The TS7 Series also features standard features of 500N Series:

  • Built-in sounder available in two- and four-wire models
  • Patented CleanMeŽ feature
  • Built-in dust compensation
  • Field-replaceable optical chamber
  • GE ESL TS7-4 - 4-Wire Photoelectric Detector W/ Remote Alarm/Trouble LED, 12/24VDC, Not Listed FM, 741U With 702U Base GE ESL TS7-4T - 4-Wire Photoelectric Smoke Detector, Remote Alarm And Trouble LED And Heat Sensors, 12/24 VDC, Smoke/Heat Algorithms, Not Listed FM, 741UT w/ 702U Base

    The TS7 Series features photoelectric smoke detectors with an easy to install and maintain head and base design. The TS7 smoke detector heads meet NFPA 72 field sensitivity testing requirements without the need for external meters.

    The photoelectric smoke detector heads are self diagnostic and have field replacable optical chambers. They feature automatic drift compensation which adjusts the alarm sensitivity when the detector gets dirty.

    The TS7-4 combines a 741U 4-wire, photoelectric sensor and 702U 6" base.

    Standard Features

  • Two or four wire head and base models
  • Intelligent, self-diagnostic
  • Built-in drift compensation
  • Field replaceable opical chamber
  • Low-profile design

    The TS7 Series also features standard features of 500N Series:

  • Built-in sounder available in two- and four-wire models
  • Patented CleanMeŽ feature
  • Built-in dust compensation
  • Field-replaceable optical chamber
  • The TS7 Series features photoelectric smoke detectors with an easy to install and maintain head and base design. The TS7 smoke detector heads meet NFPA 72 field sensitivity testing requirements withut the need for external meters.

    The photoelectric smoke detector heads are self diagnostic and have field replacable optical chambers. They feature automatic drift compensation which adjusts the alarm sensitivity when the detector gets dirty.

    The TS7-4T combines a 741UT 4-wire, photoelectric sensor, with rate-of-rise and fixed heat sensors for quick detection of both flaming and smoldering fires, and a 702U 6" base.

    Standard Features

  • Two or four wire head and base models
  • Intelligent, self-diagnostic
  • Built-in drift compensation
  • Field replaceable opical chamber
  • Low-profile design

    The TS7 Series also features standard features of 500N Series:

  • Built-in sounder available in two- and four-wire models
  • Patented CleanMeŽ feature
  • Built-in dust compensation
  • Field-replaceable optical chamber
  •    
     
     
     