Gentex GEC3-24WW 24-VDC/FWR Horn Strobe Unit White Gentex GOELP-R  Low Profile WeatherProof Backbox in Red
The Gentex GE3-24 (Commander3) Series 24 V Low-Frequency Strobes and Horn-Strobe combinations offer dependable alarms, a low current draw, and a minimum flash rate of 1 Hz regardless of input voltage.

Features

  • Silence the horn while strobes flash
  • Use the SuperSlide? feature for easy testing
  • Wide voltage range; 16 to 33 VDC or FWR
  • Many candela choices
  • Select high or low frequency, high or low volume, and temporal Code 3 or continuous tone pattern
  • Rugged die-cast metal mounting plate
  • GOELP-R Low Profile WeatherProof Backbox in Red
    Gentex GOELP-W  Low Profile WeatherProof Backbox in White GN-503 Smoke Detector
    GOELP-W Low Profile WeatherProof Backbox in White The GN-503 (120VAC/9VDC) Series of combination photoelectric smoke and
    electrochemical sensor carbon monoxide alarms are for use as an evacuation device
    in all dwelling units, including but not limited to homes, apartments, hospitals, hotels,
    motels and other commercial occupancies. The GN-503 Series is listed in
    compliance with UL 217, UL 2034, for installation per NFPA 720 and NFPA 72.
    Available in two models, the GN-503 Series is engineered to virtually eliminate
    nuisance alarms and deliver outstanding performance wherever reliable smoke and
    CO protection is required.
    The GN-503 Series is provided with a 9VDC alkaline battery for electrical
    back-up in the event building power is lost. The battery impedance is verified and the
    alarm provides a low or missing battery warning. The battery drawer provides easy
    replacement without removing the unit from the wall or ceiling.
    The Gentex GN-503 Series are provided with a self test and functionality test feature.
    The self test notifies if the smoke/CO alarm is functioning properly or needs
    attention. The functionality tests that the smoke/CO alarm is operating properly. The
    self and functionality tests are in compliance with NFPA 72 and UL Standards.
    Features of the combination alarm series include DUALINK differentiating tones
    indicating a smoke alarm (temporal 3) or a CO alarm (temporal 4), tandem
    capabilities with all Gentex tandem interconnect capable alarms. Options include a
    Form A/Form C dry contacts for remote annunciation and connection to a protected
    premises alarm system to provide a supervisory/trouble signal. The GN- 503
    provides Temporal 3 evacuation tone for smoke alarm and all units provide
    Temporal 4 tone for CO alarm annunciation. The Temporal 3 evacuation tone for
    smoke alarm will take precedence of the Temporal 4 tone for CO alarm.
    GN-503F Smoke Detector
    The GN-503 (120VAC/9VDC) Series of combination photoelectric smoke and
    electrochemical sensor carbon monoxide alarms are for use as an evacuation device
    in all dwelling units, including but not limited to homes, apartments, hospitals, hotels,
    motels and other commercial occupancies. The GN-503 Series is listed in
    compliance with UL 217, UL 2034, for installation per NFPA 720 and NFPA 72.
    Available in two models, the GN-503 Series is engineered to virtually eliminate
    nuisance alarms and deliver outstanding performance wherever reliable smoke and
    CO protection is required.
    The GN-503 Series is provided with a 9VDC alkaline battery for electrical
    back-up in the event building power is lost. The battery impedance is verified and the
    alarm provides a low or missing battery warning. The battery drawer provides easy
    replacement without removing the unit from the wall or ceiling.
    The Gentex GN-503 Series are provided with a self test and functionality test feature.
    The self test notifies if the smoke/CO alarm is functioning properly or needs
    attention. The functionality tests that the smoke/CO alarm is operating properly. The
    self and functionality tests are in compliance with NFPA 72 and UL Standards.
    Features of the combination alarm series include DUALINK differentiating tones
    indicating a smoke alarm (temporal 3) or a CO alarm (temporal 4), tandem
    capabilities with all Gentex tandem interconnect capable alarms. Options include a
    Form A/Form C dry contacts for remote annunciation and connection to a protected
    premises alarm system to provide a supervisory/trouble signal. The GN- 503
    provides Temporal 3 evacuation tone for smoke alarm and all units provide
    Temporal 4 tone for CO alarm annunciation. The Temporal 3 evacuation tone for
    smoke alarm will take precedence of the Temporal 4 tone for CO alarm.
       
     
     
     