You are here: Home > Shop Brands > Honeywell Security & Communications > Honeywell Security Kits > Burglary > Omni
We found 5 results matching your criteria.
Sort By:
Page of 1
Omni   848ATPK2 -  OMNI848EU  48 zone hybrid control system + XK108 KEYPAD + SIREN + PIR + BATTERY + TRANSFORMER + CORD + PHONEJACK - FB848ATPK Omni FB-408ATPK5 - OMNI408 control + XK108 LED keypad + 747 sounder + IS215T motion detector + 467 battery + 1321 transformer + 620 jack + 621 cord - FB408ATPK5
Honeywell’s FB-848ATPK offers Lightning Fast installation solutions and complete customer satisfaction.

The FB-848ATPK delivers unsurpassed power and versatility. Capable of handling a total of 48 zones using both wired and wireless on the same control, the FB-848ATPK is perfect for any home, apartment or business – with standard features such as a built-in telephone line monitor, 64 user codes, 128 event SmartLog, four partitions, four programmable trigger outputs, up to 20 relays and much more! Also, take advantage of our unique zone doubling option which allows you to expand the FB-848ATPK with ease and at no cost! Our unique zone doubling feature is not a system wide option as with most other security systems. You decide which zones to double or when to add-on wireless, allowing you the flexibility and comfort you deserve to meet the most demanding installation challenges.

PACK INCLUDES:

  • 1 x FB-OMNI848EU C/COM 8-48 ZONES,EURO L/TRANS
  • 1 x FB-XK108 KEYPAD, 8ZN LED, SURFACE MOUNT
  • 1 x 747 INDOOR SIREN 2 TONE WALL MOUNT
  • 1 x CK-IS215T PIR, 40 X40 W/TAMPER,IS215T
  • 1 x 467 12V4.0AH LEAD ACID RECHARG BAT
  • 1 x 1321 TRANSFORMER PLUG-IN 16.5V
  • 1 x 620 TELCO CONNECTOR CORD
  • 1 x 621 RJ31X TELEPHONE JACK

    Features:

  • Eight fully programmable wired zones standard (16 zones with our unique zone doubling option)
  • Expandable to 48 zones with hardwired or wireless
  • 16 fully programmable wired zones with our OMNIEXP8 eight hardwired zone expander (32 zones with our unique zone doubling option)
  • Operates with 5800 (exept bi-directional) wireless devices
  • Supports eight independent keyfob zones
  • Four totally programmable trigger outputs on board
  • Up to 20 fully programmable relay outputs
  • System log retains the past 128 events
    – new selectable SmartLog
  • 64 user codes with four authorization levels
  • Up to 4 partitions (3 partitions plus a common area)
  • Auto-Arming by partition
  • Tamper option by zone
  • Built-in telephone line monitor
  • Zones may be configured as wired, wireless, E.O.L., D.E.O.L., N.O., N.C. or Zone Doubling
  • Follow Me (Beeps audio format) domestic dialing
  • Paging
  • Inactivity zones programmable by partition

    INTERNATIONAL COMPASS DOWNLOADER MUST BE USED FOR PROGRAMMING

    CONTROL PANEL SPECIFICATIONS:

    Zones:
  • Eight fully programmable EOL or DEOL supervised wired zones on main board (up to 16 N.C. wired zones with our unique zone doubling option)
  • Expandable to 48 zones through plug-in modules OPTIONS: model OMNIEXP8 (eight zone wired expander), ZR401 (48 zone wireless receiver)
  • 16 traditional EOL or DEOL supervised wired zones with OMNIEXP8 zone expander module (up to 32 N.C. wired zones with our unique zone doubling option)
  • Zones seven and eight may be programmed as fast zones (10 msec)
  • Zone programming selectable as EOL, DEOL, Zone Doubling, NO, NC
  • Four Emergency keypad conditions (Fire, Panic, Personal Emergency, Duress)
  • Versatile Zone Types:
    – Controlled Zone types include: Instant, Exit/ Entry, Interior, Day, and keyswitch, with options for Fast Loop Response (zones 7 and 8), Restore, Chime, Bypass and Dialer delay by zone
    – 24 Hour Zone Types include: Fire, Burglary, Silent, Trouble, and Medical
  • Programmable central station reporting codes per zone
  • Individual reporting codes for Ambush, Panic, AC Loss, 24 Hour Test, Low Battery, Open/Close, Trouble, Restore
  • Cross zoning
  • Stay Delay Mode provides an additional 40 seconds of dialer and/or siren delay for special interior zones when armed in the stay mode
  • Arm while a zone is faulted option
  • Restore options: after siren timeout or follows loop
  • Keyswitch option per zone
  • Chime option by zone
  • Inactivity option by zone transmits signal to C.S. if zone has not been activated in a preset time

    Wireless Operation:
  • Zone wireless receiver (ZR401) attaches directly to PCB
  • Compatible with 5800 wireless peripherals (except bi-directional devices)
  • Dual diversity antenna
  • RF Jamming Option
  • Fully supervised wireless displays complete zone status, low battery and RF trouble by zone on all keypads
  • System supports eight independent keyfob zones
  • Wireless remote keyfob transmits Open/Close ID’s for each remote
  • Separate dings for arming and disarming with remote keys

    Partitions:
  • Three partitions plus a common partition
  • Zones, user codes, keypads, and remote keyfobs may be assigned to each partition
  • Extensive cross partition support
  • Separate account and pager numbers for each partition
  • Auto arming by partition
  • Inactivity zones programmable by partition
  • View all partitions from a single keypad
  • Partition descriptor uniquely identifies each partition
  • Multi partition mode allows secure operation of the system through any keypad by authorized users
  • Arm/disarm all partitions through a single keypad by authorized user
  • Partition Status keypad mode

    Outputs:
  • Four (inverted) voltage level output triggers on board and up to 20 relays programmable as follows: Burg Siren, Fire Siren, Partition Armed, Partition Ready, Entry Delay, Exit Delay, Armed Instant, Armed Stay, Sounder On, Chime, Line Seize, Phone Fail, AC Loss, Low Battery, 24 Hour Zone Trouble, 24 Hour Zone Alarm, Instant Zone Fault, Delay Zone Fault, Interior Zone Fault, Zone Tamper, RF Low Battery, RF Supervision, Communication Failure, Keypad Tamper*, Duress Code*, Panic Key*, Memory of Alarm Strobe, Trigger Zone*, Shock Sensor reset*, CS Test*, Alarm/Restore, Two-Way Voice, Momentary (seconds), Momentary (minutes), Toggle (On/Off)
    *Outputs/relays programmable duration in seconds and minutes for each partition
  • Supports up to 20 relays per system (five/per XL4705 external relay module)
  • Relays and triggers can be linked to zones, wireless remote keyfobs, keypad emergency and system conditions
  • Select time duration for momentary conditions

    User Codes:
  • 64 user codes, with four authorization levels
  • Four or six digit user codes
  • Programmable open/close ID’s for each user
  • Programmable access to partitions for each user
  • Option to transmit O/C signals by user
  • Ambush/Duress and Door Strike Codes
  • Arm/Disarm all partitions through any keypad by authorized users
  • Quick Arming, Quick Forced Arming, Quick Bypass options
  • Arm only code
  • Paging option by user

    Additional Features:
  • Cancel Code feature, with siren verify option
  • Dual entry delay timers
  • Installer Walk Test feature
  • Telephone line monitor
  • Real-time clock with reminder when time needs to be reset
  • Siren Test option, Smoke Detector reset and verification options
  • Separate alarm cutoff times for BURG and FIRE siren
  • Programmable entry/delay times, and siren lockout feature
  • Intermittent sensor shutdown option
  • Built-in Siren Driver
  • AC Based Real-time Clock (50/60hz selectable)
  • Siren Supervision
  • Busy Tone Detection
  • End-user Chime selection
  • System stabilization mode prevents false alarms during power-up
  • Recent Close and Exit Error options
  • Keypad Tamper function with optional C.S. transmission
  • Keypad Lockout Option
  • Quick Exit
  • Arm while a zone is faulted
  • Option to display zone status upon entry delay
  • Programmable Dialer Attempts programmable between 1-16
  • LED Extinguish option
  • Group Bypass option
  • AC/LB sounder disable option
  • Display bypassed zones during armed state
  • Chime on/off option through keypad
  • Single Key Arming Options by pressing either the “Stay” or “Instant” key on all FBII keypads, or by using the Chatbak-V or wireless remotes
  • Auto Stay option
  • Auto-Unbypass option
  • Flexible system test timers (1, 7, 27, 60, 90 days) with options for test by time, event or both Additional one hour test time option for high security applications

    SmartLog:
  • OMNI’s unique SmartLog option allows you to choose the events to be stored in memory
  • Panel retains past 128 events
  • 90% or 100% full indication of system log transmitted to C.S.
  • System log viewable locally at LCD keypad or uploaded to Alarm Company
  • Date (DD/MM or MM/DD) and time (24 hr. or AM/PM) option
  • End-user view option

    Keypads:
  • Supports up to 12 keypads per system. (Fixed English and custom language programmable LCD)
  • ONMI-KP-US: Fixed word LCD keypad displays status of each zone, with indications of Alarm, Fire, Trouble, Tamper, Bypass, Page, RF Supervision, Canceled, Chime, Phone, Test, AC, Battery, and Not Ready conditions
  • ONMI-LCD-US: Custom language LCD keypads display complete system status, in two line by 16 character Supertwist display for easy viewing

    Programming/Remote Operations:
  • International Compass downloader must be used for programming
  • On-site programming directly through keypads
  • Security features include special CSID and Installer codes,
  • Remote operations can be performed through single or a two call method
  • Remote operations include: arm, disarm, bypass zones, change user codes, read system status, view event log and more

    Central Station Communications:
  • Dual central station telephone numbers for each partition
  • Two CS account numbers (3 or 4 digits) for each partition
  • Pulse or DTMF dialing options
  • Pulse formats include 3+1, 4+1, 4+2, Expanded: Speeds 10, 20, 40PPS with or without parity
  • OMNI superfast, Ademco Express 4+1, and 4+2 formats, Ademco CID format
  • Split and Dual reporting option for each partition
  • Sounder ringback feature
  • Follow Me (domestic dialing), paging, beeps audio formats

    Power Specifications:
  • Total Aux. power: 500mA. regulated
  • Transformer: 16.5V 25VA
  • Alarm Power: 1 Amp

    Listings:
  • UL Household Burglary/Fire
  • California State Fire Marshal (CSFM)
  • CE, TBR21 approved

    Accessories:
  • OMNI-KP-US: Fixed word LCD keypad
  • OMNI-LCD-US: Custom language LCD keypad
  • OMNIEXP8: Eight zone wired expander (16 zones with our unique zone doubling option)
  • ZR401: 48 zone wireless receiver available in 345Mhz
  • XL4705: Relay expansion module
  • Honeywell’s powerful FB-408ATPK is the cost-effective hybrid solution for entry level installations.

    The FB-408ATPK offers lightning fast installation solutions and complete customer satisfaction.

    The FB-408ATPK is a simple, yet versatile, hybrid control panel system that provides easy installation and end-user convenience.

    The FB-408ATPK is compatible with 5800 wireless devices and supports up to six remote keyfobs without taking up any zones. With flexible trigger outputs and a large event log, the FB-408ATPK is simply the finest system in its class.

    PACK INCLUDES:

  • FB-408ATPK OMNI408 PREBOXED KIT:
    • OMNI408 control
    • XK108 LED keypad
    • 747 sounder
    • IS215T motion
    • 467 battery
    • 1321 transformer
    • 620 jack
    • 621 cord.
  • FB-ZR401 ZR401 RECEIVER 1

    Features:

  • Four hardwired zones standard
  • Eight total zones with wireless
  • Operates with 5800 (exept bi-directional) wireless devices
  • 6 user codes
  • Six independent keyfob zones
  • Two output triggers
  • 128 event history log
  • Supervised bell with temporal sound
  • False alarm prevention features
    – Exit Error
    – Fire Verification
    – Cancel Report Option
    – System Stabilization
  • Dual entry timer
  • Transmits Point ID format

    INTERNATIONAL COMPASS DOWNLOADER MUST BE USED FOR PROGRAMMING

    CONTROL PANEL SPECIFICATIONS:

    Wireless Operation:
  • ZR401- Wireless receiver attaches directly to PCB
  • Operates with 5800 (exept bi-directional) wireless devices
  • Fully supervised wireless provides zone status, low battery and RF trouble by zone
  • Six independent keyfob zones
  • Separate dings for arming and disarming with remote keyfob

    System:
  • Flexible system test times (1, 7, 27, 60, 90 days) with options for test by time, event or both
  • 128 event log, viewable locally or remotely
  • Supervised bell with temporal sound
  • Real-time clock
  • Dual entry timers
  • System stabilization mode
  • Quick exit capability
  • End-user chime control
  • Cancel code capability
  • Swinger shutdown
  • Exit error warning
  • Instant arming selection
  • Multilingual support

    Output:
  • Two voltage level trigger outputs selectable for normal or inverted operation. Options include: smoke reset, smoke power with out verification, two-way voice, burg bell, ready, armed, exit time, entry time, fire, burglary, strobe, panic, shockreset, panic, duress, RF trouble, keyfob, alarm/restore, chime

    Zones:
  • Eight zones (four wired or up to eight wireless)
  • Four emergency keypad conditions
  • Versatile zone types:
    – Controlled zone types include: instant, exit/entry, interior, day, with options for chime, bypass and dialer delay per zone
    – 24-hour types include: fire, burglary, trouble, medical
  • Arm faulted zone option
  • Restore options: after bell or follows loop

    Programming:
  • International Compass downloader must be used for programming
  • Keypad and remote programming
  • Security features include CSID, installer code, callback number, default lockout
  • On-line and unattended downloading
  • Answering machine bypass through single or two-call method

    User Codes:
  • Six user codes, programmable by master user
  • Ambush code and alarm only capability
  • Open/close by user ID CS Communications
  • Dual CS telephone and account numbers
  • Pulse or touch tone operation
  • Formats include: Ademco CID, 4+2 Express, 3+1, 4+1, 4+2, Expanded
  • Follow me, paging, beeps

    Keypads:
  • Supports up to four LED keypads (XK108)
  • Keypads display zone status, RF low battery, and RF trouble by zone
  • Dedicated LEDs display system status including: armed, ready, stay, instant, AC/low battery

    Power Specifications:
  • Total aux. power: 500mA. Regulated
  • Bell power: 1 amp.

    Listings:
  • CE, TBR21 approved
  • Omni FB-624ATPK3 - OMNI624EU 24 zone hybrid control system + OMNILCDUS KEYPAD + 747 SIREN + IS215T  PIR + BATTERY + TRANSFORMER + CORD + JACK - FB624ATPK3 Optex CA-1W Multi-Angle Wall Mounting Bracket, for use with Optex LX-402 and LX-802N Outdoor PIR Detectors
    FB-624ATPK3 24 Zone Hybrid Control System

    Honeywells FB-624ATPK offers lightning fast installation solutions and complete customer satisfaction.

    The FB-624ATPK delivers unsurpassed power and versatility. Capable of handling a total of 24 zones using both wired and wireless on the same control, the FB-624ATPK is perfect for any home, apartment or business. Standard features include a built-in telephone line monitor, 32 user codes, a 128 event SmartLog, four programmable trigger outputs, up to 20 relays and much more. Installers can also take advantage of the unique zone doubling option, which expands the FB-624ATPK with ease and at no extra cost.

    You can decide which zones to double or when to add on wireless, allowing you the flexibility and comfort you deserve to meet the most demanding installation challenges.

    PACK INCLUDES:

  • FB-OMNI624EU CONTROL & COM, 6-24 ZONES, EURO LANGUAGE TRANSLATIONS
  • FB-OMNILCDUS KEYPAD,ALPHA,W/PL3 PLASTICS
  • 747 INDOOR SIREN 2 TONE WALL MOUNT
  • CK-IS215T PIR, 40 X40 W/TAMPER
  • 467 - 12V 4.0AH LEAD ACID RECHARG. BATTERY
  • 1321 TRANSFORMER PLUG-IN 16.5V
  • 620 TELCO CONNECTOR CORD
  • 621 RJ31X TELEPHONE JACK

    Features:

  • Six fully programmable wired zones standard (12 zones with our unique zone doubling option)
  • Expandable to 24 zones with hardwired or wireless
  • Operates with 5800 (exept bi-directional) wireless devices
  • Supports eight independent keyfob zones
  • Four totally programmable trigger outputs on board
  • Up to 20 fully programmable relay outputs
  • Two partitions
  • System Log retains the past 128 Events New selectable SmartLog
  • 32 user codes with four authorization levels
  • Auto Arming
  • Tamper option by zone
  • Built-in telephone line monitor
  • Zones may be configured as wired, wireless, E.O.L., D.E.O.L., N.O.,
  • N.C. or zone doubling
  • Follow Me (Beeps audio format), domestic dialing
  • Paging
  • Inactivity zones

    INTERNATIONAL COMPASS DOWNLOADER MUST BE USED FOR PROGRAMMING

    CONTROL PANEL SPECIFICATIONS:

    Zones:
  • Six fully programmable EOL or DEOL supervised wired zones on main board (up to 12 N.C. wired zones with our unique zone doubling option)
  • Expansion through plug-in modules - OPTIONS: Model OMNIEXP8 (Eight Zone Wired Expander), ZR401 (345 MHz) wireless receivers
  • 14 traditional EOL or DEOL supervised wired zones with OMNIEXP8 zone expander module (up to 24 N.C. wired zones with our unique zone doubling option)
  • Zones five and six may be programmed as fast zones (10 msec)
  • Zone programming selectable as EOL, DEOL, Zone Doubling, NO, NC
  • Four emergency keypad conditions (Fire, Panic, Personal Emergency, Duress)
  • Versatile Zone Types:
    Controlled zone types include: instant, exit/entry, interior, day, and keyswitch, with options for fast loop response (zones 5 & 6), restore, chime, bypass and dialer delay by zone
    24 Hour Zone Types include: Fire, Burglary, Silent, Trouble, and Medical
  • Programmable central station reporting codes per zone
  • Individual reporting codes for Ambush, Panic, AC Loss, 24 Hour Test, Low Battery, Open/ Close, Trouble, Restore
  • Cross zoning
  • Stay Delay Mode provides an additional 40 seconds of dialer and/or siren delay for special interior zones when armed in the stay mode
  • Arm while a zone is faulted option
  • Restore options: after siren timeout or follows loop
  • Keyswitch option per zone
  • Chime option by zone
  • Inactivity option by partition transmits signal to C.S. if zones have not been activated in a preset time

    Wireless Operation:
  • 48 zone (ZR401) wireless receiver attaches directly to PCB
  • Compatible with 5800 wireless peripherals (except bi-directional devices)
  • Dual diversity antenna
  • Fully supervised wireless displays complete zone status, low battery and RF trouble by zone on all keypads
  • System supports eight independent keyfob zones
  • Wireless remote keyfob transmits Open/Close IDs for each remote
  • Separate dings for arming and disarming with remote keys

    Outputs:
  • Supports up to 20 relays per system (five per XL4705 External Relay Module)
  • Relays and triggers can be linked to zones, wireless remote keyfobs, keypad emergency and system conditions
  • Select time duration for momentary conditions

    Partitions:
  • Two partitions
  • Zones, user codes, keypads, and remote keyfobs may be assigned to each partition
  • Extensive cross partition support
  • Separate account and pager numbers for each partition
  • Auto arming by partition
  • Inactivity zones programmable by partition
  • View all partitions from a single keypad
  • Partition descriptor uniquely identifies each partition
  • Multi Partition mode allows secure operation of the system through any keypad by authorized users
  • Arm/disarm all partitions through a single keypad by authorized user
  • Partition Status keypad mode

    User Codes:
  • 32 user codes, with four authorization levels
  • Four or six digit user codes
  • Programmable Open/Close IDs for each user
  • Option to transmit O/C signals by user
  • Ambush/Duress and Door Strike codes
  • Quick Arming, Quick Forced Arming, Quick Bypass, QUICK EXIT options
  • Arm only code
  • Paging option by user

    Additional Features:
  • Cancel code feature, with siren verify option
  • Dual entry delay timers
  • Installer walk test feature
  • Telephone line monitor
  • Real-time clock with reminder when time needs to be reset
  • Siren Test option, Smoke Detector Reset and Verification options
  • Separate alarm cutoff times for BURG and FIRE siren
  • Programmable entry/delay times, and siren lockout feature
  • Intermittent sensor shutdown option
  • AC or crystal based Real-time clock (50/60hz selectable)
  • Siren supervision
  • End-user chime selection
  • System stabilization mode prevents false alarms during power-up
  • Recent close and exit error options
  • Keypad tamper function with optional C.S. transmission
  • Keypad lockout option
  • Quick Exit
  • Arm while a zone is faulted
  • Option to display zone status upon entry delay
  • Programmable dialer attempts programmable between 1-16
  • LED Extinguish option
  • AC/LB sounder disable option
  • Display bypassed zones during armed state
  • Chime on/off option through keypad
  • Single key arming options by pressing either the Stay or Instant key on all FBII keypads, or by using the Chatbak-V or wireless remotes
  • Auto Stay option
  • Auto Unbypass option
  • Flexible system test timers (1, 7, 27, 60, 90 days) with options for test by time, event or both. Additional one hour test time option for high security applications

    SmartLog:
  • OMNIs unique SmartLog option allows you to choose the events to be stored in memory
  • Panel retains past 128 events
  • 90% or 100% full indication of system log transmitted to C.S.
  • System log viewable locally at LCD keypad or uploaded to Alarm Company
  • Date (DD/MM or MM/DD) and time (24 hour or AM/PM) option
  • End-user log view option

    Keypads:
  • Supports up to twelve keypads per system (fixed word LCD, and custom language programmable LCD)
  • OMNI-KP-US: Fixed word LCD keypad displays status of each zone, with indications of Alarm, Fire, Trouble, Tamper, Bypass, Page, RF Supervision, Canceled, Chime, Phone, Test, AC, Battery, and Not Ready conditions
  • OMNI-LCD-US: Custom language LCD keypads display complete system status, in 2 line by 16 character Supertwist display for easy viewing

    Programming/Remote Operations:
  • International Compass downloader must be used for programming
  • On-site programming directly through keypads
  • Security features include special CSID and Installer codes, callback number, default lockout feature and option to inhibit keypad programming
  • Online and unattended downloading
  • Up/Download remotely even in the presence of fax/answering machines
  • Remote operations can be performed through single or a two call method
  • Remote operations include: arm, disarm, bypass zones, change user codes, read system status, view event log and more

    Central Station Communications:
  • Two CS account numbers (3 or 4 digits)
  • Pulse or DTMF dialing options
  • Pulse formats include 3+1, 4+1, 4+2, Expanded: Speeds 10, 20, 40PPS with or without parity
  • OMNI Superfast, Ademco Express 4+1, and 4+2 formats, Ademco CID format
  • Split and Dual reporting option
  • Sounder ringback feature
  • Follow me (domestic dialing), paging, beeps audio formats

    Power Specifications:
  • Total Aux. power: 500mA. regulated
  • Transformer: 16.5V 25VA
  • Alarm Power: 1 Amp

    Listings:
  • UL Household Burglary/Fire
  • California State Fire Marshal (CSFM)
  • CE, TBR21 approved

    Accessories:
  • OMNI-KP-US: Fixed Word LCD Keypad.
  • OMNI-LCD-US: Custom Language LCD Keypad
  • OMNIEXPX8: Eight Zone Wired Expander (16 zones with our unique zone doubling option)
  • ZR401: 48 zone wireless receiver available in 345Mhz
  • XL4705: Relay Expansion Module
  • See Optex LX-402 and LX-802N
    Optex CA-2C Multi-Angle Ceiling Mounting Bracket, for use with Optex LX-402 and LX-802N Outdoor PIR Detectors
    See Optex LX-402 and LX-802N Outdoor PIR Detectors
       
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address