Fire-Lite CHG-120F Remote Battery Charger (120 AH) Fire-Lite CHG-75 State-of-the-Art Charging System (25&75 AH)
The Fire•Lite CHG-120F is a state-of-the-art battery charging system designed for use with the Fire•Lite MS-9600, MS-9200 (requires MS-9200 circuit board #71741) and the Sensiscan 2000. It is designed to charge lead-acid batteries between 25 and 120 ampere-hours (AH). (for the Sensiscan 2000, MS-9200 and MS-9600) The Fire•Lite CHG-75 is a state-of-the-art battery charging system designed for use with the Fire•Lite MS-9600, MS-9200 and the Sensiscan 2000. * Has built-in monitor module for direct connection to the MS-9200UD or MS-9600 SLC loop. It is designed to charge lead-acid batteries between 25 and 75 ampere-hours (AH). (for the Sensiscan 2000, MS-9200 and MS-9600)
Fire-Lite FCPS-24FS6 (6 amps/4 NACs/Built In Sync) Fire-Lite FCPS-24FS8 (8 amps/4 NACs/Built In Sync)

FCPS-24FS6 Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions.

The FCPS-24FS6 is a compact, cost-effective, 6-amp remote power supply with battery charger. The FCPS-24FS6 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS6 also contains a battery charger capable ofcharging up to 18 Amp Hour batteries.

FEATURES
• UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex appliances.
• Cascadable up to 10 power supplies with strobe timing maintained.
• Operates as a sync follower or a sync generator (default).
• Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode]).
• Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF-300) for alarm activation.
• Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits.
• 6 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864).
• 4 Amp continuous output in stand-alone mode (UL 1481).
• In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two.
• Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power).
• Power-limiting technology meets UL power-limiting requirements.
• Form-C normally-closed trouble relay.
• Fully supervised power supply, battery and Notification Appliance Circuits.
• Selectable earth fault detection.
• AC trouble report selectable for immediate or 8 hour delay.
• Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power).
• Requires input trigger voltage of 9.0 - 32 VDC.
• Self-contained in compact, lockable cabinet (15" [381 mm] H x 14.5" [368 mm] W x 2.75" [70 mm] D).
• Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries.
• Battery charger may be disabled via dip switch for applications requiring larger batteries.
• Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.25 mm²) wire.

The FCPS-24FS8 is a compact, cost-effective, 8-amp remote power supply with battery charger. The FCPS-24FS8 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization or auxiliary power to support 24-volt system accessories. The FCPS-24FS8 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS8 also contains a battery charger capable of charging up to 18 Amp Hour batteries.

FEATURES
• UL Listed NAC Synchronization using System Sensor, Wheelock, or Gentex appliances.
• Cascadable up to 10 power supplies with strobe timing maintained.
• Operates as a sync follower or a sync generator (default).
• Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode]).
• Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation.
• Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits.
• 8 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864).
• 6 Amp continuous output in stand-alone mode (UL 1481).
• Compatible with coded inputs; signals passed through.
• Optional power supervision relay (A77-716B)
• In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two.
• Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power).
• Power-limiting technology meets power-limiting requirements.
• Normally-closed trouble contact.
• Fully supervised power supply, battery and Notification Appliance Circuits.
• Selectable earth fault detection.
• AC trouble report selectable for immediate or 8 hour delay.
• Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power).
• Requires input trigger voltage of 9.0 - 32 VDC.
• Self-contained in compact, lockable cabinet (15" [381 mm] H x 14.5" [368 mm] W x 2.75" [70 mm] D).
• Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries.
• Battery charger may be disabled via dip switch for applications requiring larger batteries.
• Fixed, clamp-type terminal blocks accommodate up to12 AWG (3.25 mm²) wire.

   
 
 
 