Fire-Lite ABS-8RF Annunciator surface-mount backbox Fire-Lite LDM-CBL24 Ribbon cable set 24" (60.96 cm)
ABS-8RF Annunciator surface-mount backbox with blank faceplate. Optional – LDM-CBL24, LDM-CBL48: Ribbon cable sets to provide either a 24" (60.96 cm) or 48" (121.96 cm) connection between LDM-32F/LDM-E32F and LEDs or lamps on a custom graphic panel. Includes all cables necessary for one LDM-32F or LDM-E32F. Cables have connector on one end only (split, strip and connect other end to graphic annunciator).
Fire-Lite LDM-CBL48 Ribbon cable set 48" (121.96 cm) Fire-Lite LDM-E32F: Lamp Driver Module
Optional – LDM-CBL24, LDM-CBL48: Ribbon cable sets to provide either a 24" (60.96 cm) or 48" (121.96 cm) connection between LDM-32F/LDM-E32F and LEDs or lamps on a custom graphic panel. Includes all cables necessary for one LDM-32F or LDM-E32F. Cables have connector on one end only (split, strip and connect other end to graphic annunciator). LDM-E32F: Lamp Driver Module with 32 alarm drivers; or 16 alarm, 16 trouble and 16 switch inputs. One LDME32F is allowed per LDM-32F in alarm-only mode. Three LDM-E32F modules are allowed per LDM-32F in alarm/ trouble mode. Includes expander ribbon cable.

The LDM Series Lamp Driver Modules, when combined with a custom graphic display, provide annunciation and control for the Sensiscan 2000, MS-9200, MS-9200UD, MS-9600 and MS-5210UD fire alarm control panels. These modules use a serial communications interface, and may be located up to 6,000 feet from the panel.

• ALARM/CIRCUIT ON and TROUBLE lamp/LED per-point option, or more dense alarm-only option (field-selectable).
• Control switch option for remote control per point.
• Lamps/LEDs may be programmed to display status of notification circuits or control relays as well as system status conditions.
• System trouble lamp/LED signal.
• On-line/power LED indicator.
• Alarm and trouble resound with flash of new conditions.
• Local sounder for both alarm/circuit-on and trouble conditions with silence/acknowledge switch connection.
• Serial EIA-485 interface for reduced installation cost.
• May be powered by 24 VDC from the panel or by remote power supplies.
• Efficient switched-power converter reduces power consumption.
• Microprocessor-controlled electronics, fully supervised.
• Plug-in terminal blocks for ease of installation and service.
• Trouble monitor option for remote power supplies.

Two basic models are available: the LDM-32F control module and the LDM-E32F expander module. Each may be selected to provide 32 alarm indications; or 16 alarm, 16 trouble, and 16 control points.

The LDM-32F/LDM-E32F with a custom graphic array may be used to indicate point status and, in some versions, to control the state of output points.

Fire-Lite LED-10 Remote LED-type fire annunciator Fire-Lite LED-10IM LED-10 Interface Module

LED-10 Remote LED-type fire annunciator with ten Alarm (red) and Trouble (yellow) LEDs for displaying initiating device circuit (zone) status. Includes control switches for remote control of critical system functions and key switch lock.

The Fire•Lite LED-10 Series are compact, cost-effective LED Fire Annunciators for use with the MicroScan-5210UD tenzone Fire Alarm Control/Communicator. The LED-10 Series consists of three models: the basic LED-10, the low-cost LED-10L and the Canadian LED-10LS2. The LED-10(L) is capable of illuminating Alarm (red) and Trouble (yellow) LEDs for all ten Initiating Device Circuits (IDCs). The LED-10LS2 is primarily designed for Canadian applications, and includes two yellow LEDs on zones 9 and 10 for annunciating supervisory conditions. The LED-10 Series also provides system status LEDs to display Power (green), Alarm (red), Trouble (yellow), Supervisory (yellow) and Signals Silenced (yellow). Remote control of critical system functions, such as Reset, Silence, Acknowledge and Drill, can be accomplished with the model LED-10 only.

FEATURES
• Control Switches for System Acknowledge, Signal Silence, Drill and Reset with enable key are included on model LED- 10 only (shown).
• All models include system status LEDs for Power (green), Alarm (red), Trouble (yellow), Supervisory (yellow) and Signals Silenced (yellow).
• No programming necessary.
• Aesthetically pleasing, semi-flush-mount design.
• Serial EIA-485 interface for reduced installation cost (see reverse side for wiring diagram).
• May be powered by 24 VDC from the host FACP or by remote power supplies (requires filtered, regulated power).
• Up to 32 LED-10 Series annunciators per MS-5210UD.
• Plug-in terminal blocks for ease of installation and service.
• Can be remotely located up to 6,000 feet from host control panel.
• Local piezo sounder with alarm and trouble resound.
• Semi-flush-mounts to 2-3/16" deep (minimum), threegang electrical box (Fire•Lite P/N 10103 or equivalent); or surface-mounts to Fire•Lite SBB-3 surface backbox.

LED-10IM LED-10 Interface Module (one required per MS-5210UD; supports up to 32 LED-10's).
   
 
 
 