D275 Power Supervision Module
|
USE INSTEAD OF DS-DS285 The D285 and D285TH detector heads detect the large smoke particles which typically result from wood, paper, and fabric combustion. The D285TH smoke detector also has a +135°F (+57°C) fixed temperature heat sensor. Use in areas where the ambient temperature does not exceed +100°F (+38°C). These detectors are compatible with twowire or fourwire, 12 VDC or 24 VDC circuits. Also available are addressable bases for use on the POPEX bus. Modular designCommercial or residential applicationsTwo-wire or four-wire application, depending on baseChamber Check rapid-flash LED sends contaminated chamber reportsFlashing LED power indicatorSteady-on LED alarm indicator
|
|
|
|
|
|
|
|
|
|
|
|
The D285 and D285TH detector heads detect the large smoke particles which typically result from wood, paper, and fabric combustion. The D285TH smoke detector also has a +135°F (+57°C) fixed temperature heat sensor. Use in areas where the ambient temperature does not exceed +100°F (+38°C). These detectors are compatible with twowire or fourwire, 12 VDC or 24 VDC circuits. Also available are addressable bases for use on the POPEX bus. Modular designCommercial or residential applicationsTwo-wire or four-wire application, depending on baseChamber Check rapid-flash LED sends contaminated chamber reportsFlashing LED power indicatorSteady-on LED alarm indicator
|
REPLACES DS-DS250TH The D285 and D285TH detector heads detect the large smoke particles which typically result from wood, paper, and fabric combustion. The D285TH smoke detector also has a +135°F (+57°C) fixed temperature heat sensor. Use in areas where the ambient temperature does not exceed +100°F (+38°C). These detectors are compatible with twowire or fourwire, 12 VDC or 24 VDC circuits. Also available are addressable bases for use on the POPEX bus. Modular designCommercial or residential applicationsTwo-wire or four-wire application, depending on baseChamber Check rapid-flash LED sends contaminated chamber reportsFlashing LED power indicatorSteady-on LED alarm indicator
|
|
|
|
|
|
|
|
|
|
|
|
Use the D306 Remote Indicator Plate with the D296/D297 LongRange Beam Smoke Detectors and the D340 Series Duct Smoke Detector Housings. This plate has LEDs to indicate the detector's status and test points to read the sensitivity voltage.Highlyvisible LED indicatorsSensitivity voltage test pointEasy to mount and wireAttractive faceplate
|
REPLACES DS-DIS240 Use the D307 Remote Test and Indicator Plate with the D296/D297 Long-Range Beam Smoke Detectors and the D340 Series Duct Smoke Detector Housings. This plate has LEDs to indicate the detector's status, test points to read the signal voltage, and a keyoperated test switch to test or reset the detector. Highly-visible LED indicatorsSensitivity voltage test pointKey-operated remote test and reset switchEasy to mount and wire
|
|
|
|
|
|
|
|
|
|
|
|
Includes four blocking screens and holder device for testing projected beam smoke detectors REPLACES DS-TK240
|
REPLACES DS-AL240 Installation accessory tool for ensuring proper alignment of transmitter and receiver ends of projected beam smoke detectors
|
|
|
|
|
|
|
|
|
|
|
|
REPLACES DS-DS282 Each of the D263 Series Detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. 12 V or 24 V inputDesigned for commercial or residential useLight emitting diodes (LEDs) indicate the status of the chamber, power, and alarmRemovable terminal block to simplify wiring connectionsCable connection point for voltmeter sensitivity testTrim Plate TP280 for retrofit and remodeling purposes
|
REPLACES DS-DS282TH Each of the D263 Series Detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. 12 V or 24 V inputDesigned for commercial or residential useLight emitting diodes (LEDs) indicate the status of the chamber, power, and alarmRemovable terminal block to simplify wiring connectionsCable connection point for voltmeter sensitivity testTrim Plate TP280 for retrofit and remodeling purposes
|
|
|
|
|
|
|
|
|
|
|
|
REPLACES DS-DS282THC Each of the D263 Series Detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. 12 V or 24 V inputDesigned for commercial or residential useLight emitting diodes (LEDs) indicate the status of the chamber, power, and alarmRemovable terminal block to simplify wiring connectionsCable connection point for voltmeter sensitivity testTrim Plate TP280 for retrofit and remodeling purposes
|
REPLACES DS-DS284 Each of the D273 Series Detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. The D273 Series Detector models use an infrared (IR) LED light source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to reduce dust accumulation, deter insects, and reduce nuisance alarms. 12 VDC or 24 VDC inputDesigned for commercial or residential use; Four-wire applications Light emitting diodes (LEDs) indicate the status of the chamber, power, and alarm Removable terminal block to simplify wiring connections Cable connection point for voltmeter sensitivity testTrim Plate TP280 for retrofit and remodeling purposes
|
|