Conettix IP C900V2 Dialer Capture Module is Compatible with control panels using a standard digital dialer format. Provides end-to-end security. Allows digital dialer control panels to work over an IP network (such as LAN, WAN, or the Internet). The C900V2 Dialer Capture Module works with most control panels using a standard digital dialer format and provides end-to-end security. The module links the digital dialer to the Public Switched Telephone Network (PSTN), the digital dialer?s telephone interface, and an Ethernet network. With the Ethernet link, the C900V2 can: communicate with the control panel dialer, decode and deliver signals to a D6600 Communications Receiver/Gateway, and relay a confirmation message back to the control panel dialer. Whether a control panel dials through a telephone line or through the C900V2 Dialer Capture Module, the data remains the same. The C900V2 empowers digital dialer control panels to work over an IP network such as a Local Area Network (LAN), a Wide Area Network (WAN), or the Internet. Features Captures alarm and event data from dialer-based control panels using CONTACT ID, SIA, Modem II, Modem IIe, Modem IIIa2, Pulse, and other formatsPerforms full data transmissions without changing the data12 VDC to 24 VDC voltage rangeRe-routes signals using UDP/IP-based data networksConvenient connection (RJ-45 Jack) to Ethernet networksIntegrated 10/100 Network Interface Module (NIM)
|
D8125 Addressable Expansion Module Provides expansion up to 240 points. The D8125 Addressable Expansion Module works with the D9127U or D9127T POPIT Modules to provide multiplex technology that combines zone or point supervision with individual device addressing on one pair of wires. Use the D8125 to provide expansion beyond the standard number of control panel zones, up to a total of 240 points. Each D8125 module can fully supervise 120 D9127U or D9127T POPIT Modules. Provides point identification of initiating devices Supervises wiring to devices for circuit integrity Expands the number of points in the system Compact size Terminal connections for reliability Multiplex technology Low installation costs For Control Panels D9412GV2, D7412GV2, D7212GV2, D9412G, D7412G, D7212G, D9412, D7412, D7212, D7212B1, D9112, D9112B1, D8112G1, D8112G2, and D9124
|
|
|
|
|
|
|
|
|
|
|
DS7432 Eight-Input Remote Module - Addresses up to eight input loops of conventional contacts to the multiplex bus of the control panel. The DS7432 Series Eight-input Remote Modules include the DS7432 and the DS7432E. Both modules address up to eight input loops of conventional contacts to the multiplex bus of the control panel. The DS7432E has an additional serial dual end-of-line (EOL) wiring configuration. The DS7432E addresses up to sixteen input contacts (alarm and tamper for each loop).The DS7432 uses one 47 kΩ resistor per input. The DS7432E uses 22 kΩ + 47 kΩ per input. Address up to eight input loops Serial dual end-of-line (EOL) wiring with tamper status (DS7432E) Compatibility Information The DS7432 Series modules can only connect to the following control panels with an attached multiplex expansion module. Control Panels: D9412GV2 Control Panel D7412GV2 Control Panel D9412G Control Panel D7412G Control Panel DS7400XiV4 Control Panel DS7400Xi Control Panel Multiplex Modules: D8125MUX Multiplex Bus Interface DS7430 Multiplex Expansion Module DS7436 Multiplex Expansion Module Note The DS7432E is compatible with the D9412GV2, D9412G, D7412GV2, and D7412G when the PCB jumper is set to DS7432 mode.
|
DS7457i Single Zone Input Module Connects normally-open (NO) or normallyclosed (NC) contacts, and supervises the contacts using 47 kΩ end-of-line(EOL) resistors. Designed for intrusion applications. DS7457i Series Single Zone Input Modules includes the DS7457i and the DS7457iF. Each model has a supervised-input zone for connecting normally-open or normally-closed contacts. The DS7457i Series controls the contacts using 47 kilohm end-of-line resistors. Each model operates with compatible multiplex expansion modules and occupies one multiplex zone address on the system. The DS7457i is designed for intrusion applications while the DS7457iF is designed for fire applications. Features Power limited and supervised input zonesCompact enough to fit within most back boxes and enclosuresAddress settings through DIP switchesREPLACES DS-DS7457
|
|
|
|
|
|
|
|
|
|
|
|
DS7457iF Single Zone Input Module Connects normally-open (NO) or normallyclosed (NC) contacts, and supervises the contacts using 47 kΩ end-of-line(EOL) resistors. Designed for fire applications. DS7457i Series Single Zone Input Modules includes the DS7457i and the DS7457iF. Each model has a supervised-input zone for connecting normally-open or normally-closed contacts. The DS7457i Series controls the contacts using 47 kilohm end-of-line resistors. Each model operates with compatible multiplex expansion modules and occupies one multiplex zone address on the system. The DS7457i is designed for intrusion applications while the DS7457iF is designed for fire applications. Features Power limited and supervised input zonesCompact enough to fit within most back boxes and enclosuresAddress settings through DIP switchesREPLACES DS-DS7457
|
The DS7460i is a Dual Zone Input Module designed to operate with compatible multiplex systems. It is DIP switch programmable and provides two supervised input zones for connection of conventional normally-open (N/O) or normally-closed (N/C) contacts. Each DS7460i occupies two multiplex zone addresses on the system and can monitor up to two separate zones. The DS7460i is compatible the D8125MUX Multiplex Expansion Module, the G Series Control Panels, and the D9124 Control Panel. Features Supervises two protection loopsCan be used in UL Listed fire and security applicationsDIP switch programmable
|
|
|
|
|
|
|
|
|
|
|
|
The DS7461i is a Single Zone Input Module designed to operate with compatible multiplex systems. It is DIP switch programmable and provides a supervised input zone for connection of conventional normally open (N/O) or normally closed (N/C) inputs. Each DS7461i occupies one multiplex zone address on the system. Features Supervises one power-limited protection loopCan be used in UL Listed fire and security applicationsDIP switch programmable
|
The DS7465i works with compatible multiplex systems. It supplies a DIP switch programmable Form C relay (output zone) that activates on system events. The DS7465i provides an input zone intended to monitor conventional normally-open (NO) or normally-closed (NC) contacts and report their status as a multiplex address to the control system. The DS7465i occupies two multiplex addresses. Use up to sixty DS7465i modules with compatible control panels or multiplex expansion modules. Features Supervises one power-limited input zoneProvides one output relayCan be used in UL Listed fire and security applicationsDIP switch programmableREPLACES DS-DS7465
|
|
|
|
|
|
|
|
|
|
|
|
The DX2010 Input Expander Series includes the DX2010 Input Expander, the DX2011 Package, and the DX2012 Package. The DX2010 connects directly to the data bus of a compatible control panel. Each expander adds eight input loops. Install up to five expanders in a control panel's enclosure (three on the interior sidewalls and two on the back wall of the enclosure). The DX2010 Input Expander includes the DX2010 board. The DX2011 Package includes a DX2010 with a D203 Metal Enclosure. The DX2012 Package includes a DX2010 with an AE20 Plastic Enclosure. Features Up to eight sensor input loopsDirectly connects to the control panel data bus
|
DX2011 PackageAdds eight input loops. Connects directly to the control panel data bus. Five per enclosure.Includes a DX2010 Input Expander with a D203 Metal Enclosure.
|
|
|
|
|
|
|
|
|
|
|
|
DX4010V2 Serial Interface Module, which allows you to locally program compatible Bosch control panels The DX4010V2 USB/Serial Interface Module creates a local connection between compatible control panels and approved applications.
|
FutureSmart INS-BLRA 10-Pack of Blank Inserts for Receptacles - Almond
|
|