PL-APCB POTTER ACCUMULATOR F/ EVD
|
2000106 APC - Accumulation Pulse Counter
|
|
|
|
|
|
|
|
|
|
|
|
5090008 Back Box for PSM-F PL-5090008 BACK BOX FOR PSMF
|
5090033 Back Box for PTU-B PL-5090033 A BACKBOX FOR PTUB CANNOT BE USED IN CANADA
|
|
|
|
|
|
|
|
|
|
|
|
5130080 Battery 6V, 4 AH PL-5130080
|
PL-EVD2 Electronic Vibration Detection System EVD-2 SYSTEM 2020300 CONSISTING OF: 1 EVD-M Controller 2020250 1 EVD-R Remote Pickup 2020260 EVD-2C Safe/Vault Pak Includes: HSC-1 High security safe contact The EVD-2, Electronic Vibration Detector System, is listed by Underwriters Laboratories, Inc. for primary protection of Mercantile or Bank, safe or vault, ATM machines and supplementary protection of interior units such as file cabinets, display cases, walls and ceilings. The System must be used with an appropriate UL listed control unit. The standard EVD-2 system consists of a model EVD-M controller and a model EVD-R remote pickup. FEATURES • Detects all common threats to safes and vaults. • Sophisticated signal processing provides unprecedented sensitivity without false alarms. • Expandable system allows up to 15 remote pickups, (Model EVD-R). • Reliable, sensitive piezo sensor technology. • On board high security safe contact interface. • Integral, multi-color status LED. • Built in test circuit on both controller and remote pickups. • Remote test and annunciator capabilities. • Supervised microprocessor. • Independent tamper output. • On board test point facilitates installation and service. • Built in accumulator.
EVD-M CONTROLLER The EVD-M controller detects short duration, large amplitude signals like those produced in attacks from explosions, hammering or chiseling. It also detects long duration, small amplitude signals like those produced in attacks from torches, thermic lances, drills, grinders or cutting discs. As soon as the EVD-M detects a large amplitude alarm source it signals an alarm. The EVD-M controller supports up to 15 EVD-R remote pickups, (or may be used as a stand alone unit), and fully supervises EVDR wiring.
|
|
|
|
|
|
|
|
|
|
|
|
PL-EVDC Electronic Vibration Amplifier The amplifier unit, model EVD-C, provides SPDT alarm contacts for connection into the alarm protective circuit. The EVD-C is housed in a metal cabinet protected by a cover tamper and a housing vibration detector. The housing detector is provided with a housing sensitivity control. A low voltage plug-in transformer and a regulated battery charging circuit maintain the standby battery at a fully charged state. An auxiliary output is provided to power the APC-B (accumulator option) when required. The battery provides in excess of 80 hours standby operation even if the maximum 6VDC auxiliary output is utilized. The EVD-C provides an AC on indicator (green LED), a test button, and an alarm indicator (red LED) for subscriber testing of the EVD-S System. Terminals are also provided for connection of a remote test unit, Model PTU-B, and/or connection of dry contacts from any Underwriters Laboratories Listed central station test unit. From 2 to 15 pickup units may be connected to the EVD-C in a series supervised pickup loop. The supervision of the pickup loop is maintained by a factory adjusted DC differential circuit, which makes
|
PL-EVDM MASTER UNIT EXPANDBLE EVD-M CONTROLLER The EVD-M controller detects short duration, large amplitude signals like those produced in attacks from explosions, hammering or chiseling. It also detects long duration, small amplitude signals like those produced in attacks from torches, thermic lances, drills, grinders or cutting discs. As soon as the EVD-M detects a large amplitude alarm source it signals an alarm. The EVD-M controller supports up to 15 EVD-R remote pickups, (or may be used as a stand alone unit), and fully supervises EVDR wiring.
|
|
|
|
|
|
|
|
|
|
|
|
PL-EVDP Electronic Vibration Pick-up Unit EVD-P PICKUP UNIT Model EVD-P pickup units detect sound vibrations in the protected material. These signals are fed to the amplifier unit where the pickup loop sensitivity control determines the signal level necessary to create an alarm condition. A Model EOLR resistor assembly must be installed in the last EVDP.
The pickup units are housed in a 4 1/4"H x 3"W x 1 1/4"D metal enclosure with cover and back tampers and are to be mounted with the speaker opening against the protected material.
|
EVD-R Remote Pickup 2020260 for EVD-2 PL-EVDR
|
|
|
|
|
|
|
|
|
|
|
|
REPLACES AS-MBA824 PBA248 1808024 8" (200mm) 24VAC CURRENT (MAX.) .17A TYPICAL dB AT 10 FT. (3m) (2) 94 MINIMUM dB AT 10 FT. (3m) (1) 76 These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL Listed, FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION
|
PFC-100RC RELEASING CONTROL PANEL General Description The PFC-100RC is a full featured single hazard releasing control panel for use on pre-action and deluge type sprinkler systems. The model PFC-100RC is Underwriters Laboratories Listed and complies with UL Standard 864 for Local Control Units for Releasing Service. It is designed to be compatible with the requirements of NFPA- 72, NFPA-12, NFPA-12A, NFPA-12B, NFPA-13 and NFPA-17. The PFC-100RC is FM, NYMEA and CSFM Approved.
The PFC-100RC features LED indicators for AC, ALARM, TROUBLE, SILENCE, and SUPERVISORY conditions that are visible with the door closed. Operator controls are provided for RESET, SILENCE, and RELEASE CIRCUIT DISABLE. Thirteen on board LED indicators provide extensive diagnostic ability to ease troubleshooting. Alarm and trouble relays are provided to interface with auxiliary equipment.
Dimensions: 18 1/4" X 14 1/4" X 4 3/4" The PFC-100RC is housed in a steel cabinet with removable door and key lock. Standard finish is off-white with grey and red trim. Red cabinets with black and white trim are also available. A matching bezel is available as an option for semi-flush mounting in a wall. The cabinet will house up to a 12AH standby battery which is capable of powering the unit in excess of 90 hours. Features • One Initiating Device Circuit Selectable Class A or Class B • One Class B Circuit for dry contact devices • One 500mA Class B Indicating Circuit • One 1 Amp Class B Releasing Circuit • One Class B Supervisory Circuit • 2 Amps Alarm and Trouble Contacts • 200mA Auxiliary Power Output • Supervised Integral Battery Charger • Supports 2 or 4-Wire Detectors • Field Selectable Pre-Discharge and Releasing Circuit Times The PL-PFC100RCW REPLACES PL-PFC100RW
|
|