Fire Systems

  Bells
  Fire Alarm Panels
  PULL STATION SERIES
  Smoke Detectors
  Sprinkler
  Tamper/Supervisory Switches
  Voice Evacuation
Potter Fire Systems
Bells
PBA-AC & PBD-DC BELLS
Fire Alarm Panels
Fire Alarm Panels
PULL STATION SERIES
PULL STATION SERIES
Smoke Detectors
Smoke Detectors
Sprinkler
Sprinkler
Tamper/Supervisory Switches
Voice Evacuation
Voice Evacuation
Sort By:
Page of 7
Potter 16.5 VAC Transformer Potter ARM-2 Auxiliary Relay Module 3006300
1000394 16.5 VAC Transformer The ARM-2 Auxiliary Relay Module is a UL listed option when factory installed in the Potter PFC- 2000RC or the Potter PFC-4410.

When the ARM-2 is used the additional power required for this relay module must be subtracted from the total circuit current available. See PFC- 2000RC Manual 5403521, DWG. #3521-1, Note 12 or PFC-4410 Manual 5403527, page 7, Output Circuits.

The ARM-2 Auxiliary Relay Module is a nonsupervised DPDT Relay designed to be activated by 24VDC Indicating and/or Releasing, polarity reversing circuits. The module can be used for fan shutdown, door release, elevator recall, etc. Note: One to three ARM-2 modules in the PFC- 2000RC or one to four ARM-2 modules in the PFC-4410 may be utilized to provide multiple auxiliary functions.

  • UL Listed: For use with the PFC-2000RC and PFC-4410
  • Dimensions: 2 1/4" x 3 1/2" x 3"
  • Weight: .315 lb.
  • Assembly: Socketed relay in plastic mounting track
  • Power Requirements: 40mA at 24VDC
  • Contact Ratings: Each relay has DPDT contacts, Rated at 10 amps resistive, 120/240VAC, 0-30VDC
  • Stock No. 3004725
  • Potter Auxiliary Form C relay Potter BT-120 Battery, 12V 12.0AH for 90 Hr. Standby
    1000314 Auxiliary Form C relay

    PL-1000314 A RELAY MODULE FOR 7500 SERIES

    5130090 BT-120 Battery, 12V 12.0AH for 90 Hr. Standby (2 pcs required)
    Potter BT-260 Battery, 12V 26AH 5130097 Potter BT-40 Battery, 12V 4.0AH for 24 Hr. Standby
    BT-260 26 AH Battery (requires battery cabinet) 5130097 5130092 BT-40 Battery, 12V 4.0AH for 24 Hr. Standby (2 pcs required)
    Potter BT-80 Battery, 12V 8.0AH for 60 Hr. Standby Potter CA2Z 2 Zone Class A Initiating Circuit Module 3006013
    5130084 BT-80 Battery, 12V 8.0AH for 60 Hr. Standby (2 pcs required) The Model CA2Z Class A Module is designed to be used with the PFC-4410 Fire Control Releasing Panel to convert from two (Class B) initiating device circuits to two (Class A) circuits.

    The module is to be mounted in the upper right hand corner of the panel. Connection to the panel is made via the 8 pin header mounted on the back side of the CA2Z.

  • UL LISTED: Option for use with the PFC-4410
  • TRANSIENT PROTECTED
  • BUILT IN 5.1K END OF LINE RESISTOR
  • PC BOARD ASSEMBLY: Mounts to PFC-4410 Panel stand-offs
  • Stock No. 3006013 PL-CA2Z
  • Potter CFG-5000 Configuration and Diagnostics Tool for the DACT-5000 Potter CFG-5000 Programmer for UDACT
    3002110 CFG-5000 Configuration and Diagnostics Tool for the DACT-5000

    PL-CFG5000 DIALER CONFIGURATION TOOL

    3002110 CFG-5000 Programmer for UDACT

    PL-CFG5000 DIALER CONFIGURATION TOOL

    Potter DACT-5000 Digital Alarm Communication Transmitter / Dialer Module Potter Electric OSYSU1 - A SUPERVISORY SWITCH SINGLE PULL DOUBLE THROW
    3002105 DACT-5000 Digital Alarm Communication Transmitter / Dialer Module (Requires CFG-5000) PL-DACT5000 2 LINE TELEPHONE DIALER POTTER ELECTRIC - U.S. 141.88 General Information
    The OSYSU is used to monitor the open position of an OS&Y (outside
    screw and yoke) type gate valve. This device is available in two models;
    the OSYSU1,
    containing one set of SPDT (Form C) contacts and the
    OSYSU2,
    containing two sets of SPDT (Form C) contacts. These
    switches mount conveniently to most OS&Y valves ranging in size from
    2" to 12" (50mm to 300mm). They will mount on some valves as small
    as " (12,5mm).
    The cover is held in place by two tamper resistant screws that require a
    special tool to remove. The tool is furnished with each device and should be
    left with the building owner or responsible party. Replacement or additional
    cover screws and hex keys are available. See Ordering Information.
    Optional Cover Tamper Switch
    A fi eld installable cover tamper switch is available as an option which may
    be used to indicate removal of the cover. See Ordering Information.
    Testing
    The OSYSU and its associated protective monitoring system should
    be inspected and tested in accordance with applicable NFPA codes
    and standards and/or the authority having jurisdiction (manufacturer
    recommends quarterly or more frequently).

       
     
     
     