Altronix AL1002UL2ADA - NAC Power Extender. 24VDC @ 10A. Class 2. Wheelock. Altronix AL1042UL2ADA - NAC Power Extender. 24VDC @ 10A. Class 2. Wheelock.

AL1002UL2ADA

NAC Power Extender

Overview

Model AL1002UL2ADA is an extremely cost effective 10 amp voltage regulated remote power supply/battery charger. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories. The unit delivers regulated and filtered 24 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.0A auxiliary output with reset for four (4)-wire smoke detectors is available. The 10 amp rated supply current can be divided between the four (4) outputs for powering NAC devices. Each output is rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also features “Loop Output” trouble memory indication to help identify troublesome sporatic problems.

Agency Listings


• UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL1481). File# S5075.
• CSFM - California State Fire Marshal Approved. File# 7315-1335:111.
• MEA - NYC Department of Buildings Approved.

Features/Specifications

Power Supply/Charger:
• 24VDC output.
• 10 amp max total alarm current.
• 115VAC 60Hz., 4.4 amp.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
• Lifetime Warranty.

Logic Board:


• Class 2 Rated power limited outputs.
• Two (2) Class A or two (2) Class B FACP inputs.
• Two (2) NC dry contact trigger inputs.
• Two (2) Class A or four (4) Class B Indicating Circuits.
• Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
• One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
• Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs.
• 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
• Horn/Strobe sync protocols include: Wheelock, Gentex, System Sensor, Faraday, Amseco.
• Temporal Code 3 Mode.
• Steady Mode.
• Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
• Compatible with 24VDC or 12VDC fire panels.
• Common Trouble inputs and outputs.
• Ground fault detection.
• Lifetime Warranty.

Enclosure


• Accommodates up to two (2) 12VDC/12AH batteries.
• Dimensions: 18”H x 14.5”W x 4.625”D.
• 1/2" and 3/4" combination knockouts.

AL1042UL2ADA

NAC Power Extender

Overview

Model AL1042UL2ADA is an extremely cost effective 10 amp voltage regulated remote NAC Power Extender. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories. The unit delivers regulated and filtered 24 volt power via up to eight (8) Class B, four (4) Class A or combination of Class B and Class A Notification Appliance Circuits. Additionally, the unit can supply up to 1 amp from continous AUX output and up to 1 amp from AC disconnected AUX output. The 10 amp rated supply current can be divided between the four (4) outputs for powering notification appliances and the AUX outputs. Each output is rated at 2.5 amp max (total not to exceed 10 amp), and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition units provide independent loop supervision for Class A and/or Class B FACP NAC circuits. In the event of a loop trouble the FACP will be notified via steered inputs (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be connected to power extender inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also feature “Loop Output” trouble memory indication to help identify troublesome sporatic loop problems.

Agency Listings


• UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL1481). File# S5075.
• CSFM - California State Fire Marshal Approved. File# 7315-1335:112.
• MEA - NYC Department of Buildings Approved.

Features/Specifications

Power Supply/Charger:
• 24VDC output.
• 10 amp max total alarm current.
• 115VAC 60Hz., 4.4 amp.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
• Lifetime Warranty.

Logic Board:


• Class 2 Rated power limited outputs.
• Two (2) Class A or two (2) Class B FACP inputs.
• Two (2) NC dry contact trigger inputs.
• Four (4) Class A or four (4) Class B Indicating Circuits.
• Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
• One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
• One (1) Aux. Power Output @ 1 amp supply current (w/o Battery Back Up).
• Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs.
• 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
• Horn/Strobe sync protocols include: Wheelock, Gentex, System Sensor, Faraday, Amseco.
• Temporal Code 3 Mode.
• Steady Mode.
• Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
• Compatible with 24VDC or 12VDC fire panels.
• Common Trouble inputs and outputs.
• Ground fault detection.
• Lifetime Warranty.

Enclosure


• Accommodates up to two (2) 12VDC/12AH batteries.
• Dimensions: 18”H x 14.5”W x 4.625”D.
• 1/2" and 3/4" combination knockouts.
Altronix AL602UL2ADA - NAC Power Extender. 12/24VDC @ 6.5A. Class 2. Wheelock. Altronix AL642UL2ADA - NAC Power Extender. 12/24VDC @ 6.5A. Class 2. Wheelock.

AL602UL2ADA

NAC Power Extender

Overview

Model AL602UL2ADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery charger. It may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories. The unit delivers regulated and filtered 24 or 12 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.0A auxiliary output with reset for four (4)-wire smoke detectors is available. The 6.5 amp rated supply current can be divided between the four (4) outputs for powering NAC devices. Each output is rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also features “Loop Output” trouble memory indication to help identify troublesome sporatic problems.

Agency Listings


• UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL1481). File# S5075.
• CSFM - California State Fire Marshal Approved. File# 7315-1335:111.
• MEA - NYC Department of Buildings Approved.

Features/Specifications

Power Supply/Charger:
• 12VDC or 24VDC selectable output.
• 6.5 amp max total alarm current.
• 115VAC 60Hz., 1.45 amp.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
• Lifetime Warranty.

Logic Board:


• Class 2 Rated power limited outputs.
• Two (2) Class A or two (2) Class B FACP inputs.
• Two (2) Class A or four (4) Class B Indicating Circuits.
• Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
• One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
• Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs.
• 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
• Horn/Strobe sync protocols include: Wheelock, Gentex, System Sensor, Faraday, Amseco.
• Temporal Code 3 Mode.
• Steady Mode.
• Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
• Compatible with 24VDC or 12VDC fire panels.
• Common Trouble inputs and outputs.
• Ground fault detection.
• Lifetime Warranty.

Enclosure


• Accommodates up to two (2) 12VDC/12AH batteries.
• Dimensions: 18”H x 14.5”W x 4.625”D.
• 1/2" and 3/4" combination knockouts.

AL642UL2ADA

NAC Power Extender

Overview

Model AL642UL2ADA is an extremely cost effective 6.5 amp voltage regulated remote NAC Power Extender. It may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories. The unit delivers regulated and filtered 24 or 12 volt power via up to eight (8) Class B, four (4) Class A or combination of Class B and Class A Notification Appliance Circuits. Additionally, the unit can supply up to 1 amp from continous AUX output and up to 1 amp from AC disconnected AUX ouput. The 6.5 amp rated supply current can be divided between the four (4) outputs for powering notification appliances and the AUX outputs. Each output is rated at 2.5 amp max (total not to exceed 6.5 amp), and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition units provide independent loop supervision for Class A and/or Class B FACP NAC circuits. In the event of a loop trouble the FACP will be notified via steered inputs (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be connected to power extender inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also feature “Loop Output” trouble memory indication to help identify troublesome sporatic loop problems.

Agency Listings


• UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL1481). File# S5075.
• CSFM - California State Fire Marshal Approved. File# 7315-1335:112.
• MEA - NYC Department of Buildings Approved.

Features/Specifications

Power Supply/Charger:
• 12VDC or 24VDC selectable output.
• 6.5 amp max total alarm current.
• 115VAC 60Hz., 3.2 amp.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
• Lifetime Warranty.

Logic Board:


• Class 2 Rated power limited outputs.
• Two (2) Class A or two (2) Class B FACP inputs.
• Two (2) NC dry contact trigger inputs.
• Four (4) Class A or four (4) Class B Indicating Circuits.
• Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
• One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
• One (1) Aux. Power Output @ 1 amp supply current (w/o Battery Back Up).
• Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs.
• 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
• Horn/Strobe sync protocols include: Wheelock, Gentex, System Sensor, Faraday, Amseco.
• Temporal Code 3 Mode.
• Steady Mode.
• Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
• Compatible with 24VDC or 12VDC fire panels.
• Common Trouble inputs and outputs.
• Ground fault detection.
• Lifetime Warranty.

Enclosure


• Accommodates up to two (2) 12VDC/12AH batteries.
• Dimensions: 18”H x 14.5”W x 4.625”D.
• 1/2" and 3/4" combination knockouts.
Altronix AL802UL2ADA - NAC Power Extender. 12/24VDC @ 8A. Class 2. Wheelock. Altronix AL842UL2ADA - NAC Power Extender. 12/24VDC @ 8A. Class 2. Wheelock.

AL802UL2ADA

NAC Power Extender

Overview

Model AL802UL2ADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery charger. It may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories. The unit delivers regulated and filtered 24 or 12 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.0A auxiliary output with reset for four (4)-wire smoke detectors is available. The 8 amp rated supply current can be divided between the four (4) outputs for powering NAC devices. Each output is rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also features “Loop Output” trouble.

Agency Listings


• UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL1481). File# S5075.
• CSFM - California State Fire Marshal Approved. File# 7315-1335:111.
• MEA - NYC Department of Buildings Approved.

Features/Specifications

Power Supply/Charger:
• 12VDC or 24VDC selectable output.
• 8 amp max total alarm current.
• 115VAC 60Hz., 1.45 amp.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
• Lifetime Warranty.

Logic Board:


• Class 2 Rated power limited outputs.
• Two (2) Class A or two (2) Class B FACP inputs.
• Two (2) NC dry contact trigger inputs.
• Two (2) Class A or four (4) Class B Indicating Circuits.
• Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
• One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
• Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs.
• 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
• Horn/Strobe sync protocols include: Wheelock, Gentex, System Sensor, Faraday, Amseco.
• Temporal Code 3 Mode.
• Steady Mode.
• Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
• Compatible with 24VDC or 12VDC fire panels.
• Common Trouble inputs and outputs.
• Ground fault detection.
• Lifetime Warranty.

Enclosure


• Accommodates up to two (2) 12VDC/12AH batteries.
• Dimensions: 18”H x 14.5”W x 4.625”D.
• 1/2" and 3/4" combination knockouts.

AL842UL2ADA

NAC Power Extender

Overview

Model AL842UL2ADA is an extremely cost effective 8 amp voltage regulated remote NAC Power Extender. It may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories. The unit delivers regulated and filtered 24 or 12 volt power via four (4) Class B, four (4) Class A or two (2) Class B and two (2) Class A Notification Appliance Circuits. Additionally, the unit can supply up to 1 amp from continous AUX output and up to 1 amp from AC disconnected AUX ouput. The 8 amp rated supply current can be divided between the four (4) outputs for powering notification appliances and the AUX outputs. Each output is rated at 2.5 amp max (total not to exceed 8 amp), and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition units provide independent loop supervision for Class A and/or Class B FACP NAC circuits. In the event of a loop trouble the FACP will be notified via steered inputs (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be connected to power extender inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also feature “Loop Output” trouble memory indication to help identify troublesome sporatic loop problems.

Agency Listings


• UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL1481). File# S5075.
• CSFM - California State Fire Marshal Approved. File# 7315-1335:112.
• MEA - NYC Department of Buildings Approved.

Features/Specifications

Power Supply/Charger:
• 12VDC or 24VDC selectable output.
• 8 amp max total alarm current.
• 115VAC 60Hz., 3.2 amp.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
• Lifetime Warranty.

Logic Board:


• Class 2 Rated power limited outputs.
• Two (2) Class A or two (2) Class B FACP inputs.
• Two (2) NC dry contact trigger inputs.
• Four (4) Class A or four (4) Class B Indicating Circuits.
• Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
• One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
• One (1) Aux. Power Output @ 1 amp supply current (w/o Battery Back Up).
• Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs.
• 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
• Horn/Strobe sync protocols include: Wheelock, Gentex, System Sensor, Faraday, Amseco.
• Temporal Code 3 Mode.
• Steady Mode.
• Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
• Compatible with 24VDC or 12VDC fire panels.
• Common Trouble inputs and outputs.
• Ground fault detection.
• Lifetime Warranty.

Enclosure


• Dimensions: 18”H x 14.5”W x 4.625”D.
• 1/2" and 3/4" combination knockouts.
Bioscrypt BV-VENCHT V-Prox/V-Pass/V-Flex Outdoor Enclosure With Heater Bioscrypt BV-VENCW V-Prox/V-Pass/V-Flex Outdoor Enclosure With Window
BVVENCHT V-Prox/V-Pass/V-Flex Outdoor Enclosure with Heater

Dimensions: 11.5" H x 8.07" W x 5.5" D (29.2cm H x 20.5cm W x 14.0cm D). Lid lifts up and is 11.25" H x 9.25" W (28.6cm H x 23.5cm W).

BVVENCW V-Prox/V-Pass/V-Flex Outdoor Enclosure with Window

Dimensions: 11.5" H x 8.07" W x 5.5" D (29.2cm H x 20.5cm W x 14.0cm D). Lid lifts up and is 11.25" H x 9.25" W (28.6cm H x 23.5cm W).

Bioscrypt BV-VENCWEHT V-Station A Outdoor Enclosure With Heater Bioscrypt BV-VTENCWHT V-Smart Outdoor Enclosure With Window & Heater
BV-VENCWEHT OUTDOOR HOUSING W/HEATER FOR BV-VSTATIONA BVVTENCWHT V-Smart Outdoor Enclosure with Window & Heater

Dimensions: 11.5" H x 8.07" W x 5.5" D (29.2cm H x 20.5cm W x 14.0cm D). Lid lifts up and is 11.25" H 9.25" W x (28.6cm H x 23.5cm W). Reader not included.

GE/Kalatel KA-KBI540A Black And White High Resolution Indoor ExView 600 3.5-8VA GE/Kalatel KA-KBI540B Black And White High Resolution Indoor ExView 600 3.5-8VM
GE Security makes ordering cameras as easy as a single part number with our brand new CamPlete camera. Choose from more than a dozen solutions, all of which include: camera with lens, back focused, installed power supply, mounting kit, housing (for outdoor applications), choose Black&White, Color, Day/Night or even the new UltraView Wide Dynamic range camera. Look for the single part number that fits your needs and you're all set.


Features and Benefits:

- Complete camera system in a box

- Easy installation

- Special pricing

- Convenient just one part number

B/W, high resolution, ExView, 600 TVL, 0.01 lux, Indoor, 3.5-8mm manual


CamPlete camera kits come with everything you need for a complete video camera solution. Indoor kits include camera, lens, and wall mount. Outdoor kits come with camera, lens, wall mount, housing, and ready-to-connect power and video cables. With everything preassembled, installation time is dramatically reduced. The lens is attached, the camera is in the housing, and even the back focus is set at the factory. Ordering is made easier: use one part number instead of several.


Standard Features:

* Factory assembled and ready to install, reducing labor and installation costs

* Preconfigured indoor camera system includes camera, lens, and wall mount

* Preconfigured outdoor camera system includes camera, lens, wall mount, housing, and ready-to- connect power and video cables

* Wide range of CamPlus color and black-and-white cameras available

* UltraView and Day/Night technology available

* Autoiris lenses installed and back focus set at factory

   
 
 
 

Enter your email for a chance to WIN $100 Amex Gift Card.

Please Enter Your Email Address

*One entry per household please