You are here: Home > Shop Brands > Corby Industries
We found 118 results matching your criteria.

McAfee Secure sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams

Corby Industries

  Accessories
  System 10
  System 2
  System 5
Corby Access Control Systems and Corby Keypads have been locking doors and protecting millions of people for over 35 years. We're so good at it that our customers put us in the same league as a Mercedes-Benz. We invented the first Digital Keypad back in 1
Accessories
A wide range of accessories for use with Corby Systems.
System 10
The System 10 Access Control System supports thousands of users. Each user can be added or deleted in seconds using a computer which Corby can supply (part #4450) and printer (part #4006). The built-in relays can switch power to electric Door Locks, arm o
System 2
Our rugged and time tested System2 Access Control System supports over 6,000 users and each user can be added or deleted in seconds using the built-in Programming Keypad. The programmable relays can control almost any device including electric door locks,
System 5
The System 5 Access Control System supports up to 750 users. Each user can be added or deleted in seconds using the supplied Video Display Terminal (VDT). The built-in relays can switch power to electric Door Locks, arm or disarm Alarm Systems, shunt Alar
Sort By:
Page of 10
Corby 4009 - SCU/SLAVE/BATT TRANSFER Corby 6566 - Programmable Digital Keypad - Cast metal,Heavy-duty, Outdoor
System 5 Expansion Panel ● Also called a "slave" control unit ● Connects to a master panel (25-4000) via 3 shielded wires ● Increases total system capacity to 8 doors, 8 zones and 1 aux ● All functions of the slave panel are the same as the master, except the master is used for all programming functions ● Telecommunications Board (41-4021) not included nor required with slave expansion panel ● Includes battery and transformer ● Cabinet: 11" W x 15.5" H x 4.5" D (279mm x 394mm x 114mm)

Programmable Digital Keypad - Cast metal,Heavy-duty, Outdoor

This is a "stand-alone" access control system designed for low cost and easy installation using a minimal amount of additional components. All you need for minimal operation is a simple 12 or 24 VDC power supply and an electric door lock. All necessary relays and other security features are built into its thin profile, allowing most models to be installed into a standard electrical box.

This 6500 Series replaces our 6000 Series. It is exactly the same as the 6000 except the printer option has been removed and replaced with 165 user codes, a security lockout feature and increased voltage range to 24 VDC. This keypad is ideal for storage rooms, garage door, utility rooms, vehicle alarms, activating a security camera, arming, disarming or shunting a security system and other security applications. A tamper switch should be used or a fused line should be activated when the unit is removed from the mounting area.

  • EEPROM Memory
  • 165 User Codes
  • Security Lockout
  • Duress Codes
  • Auxiliary Codes
  • Forced Entry Input
  • 3-6 Code Length
  • Door Ajar
  • Time Cancel
  • 12-24 VDC Operation
  • RTE Input
  • Audible Key Beep
  • Panic Code
  • Cast metal
  • Heavy-duty
  • Outdoor
  • Flush mount
  • Green and Red LED
  • 3.23" X 5.0"
  • Corby 7520 - Platinum Series Keypad - Mullion-Style,Slim Corby 7530 - Platinum Series Keypad - Aluminum Cover, Outdoor

    Platinum Series Keypad - Mullion-Style,Slim

    The Platinum Series Keypad is made from a solid block of aluminum, this keypad utilizes piezoelectric technology to provide the security installer with the elegance your customer wants and the ruggedness that your customer needs! It is resistant to the effects of Mother Nature and vandals.

    The keypad is a stand-alone unit, requiring only a power supply and electric door lock to operate. Programming is done at the keypad, and it has the capacity to hold over 200 different user codes! Code lengths may be from 4 to 8 digits in length, giving your customer 100 million code combinations! All codes are stored in nonvolatile memory, so if you lose power to the unit, your codes will still be there when power returns.

    To ease the installation, this keypad requires only four (4) wires to install (two for power and two for the lock) and can operate on 12 to 24 Volts DC or 12 Volts AC. For magnetic lock installations, a request-to-exit button can be wired in for fail-safe operation.

    For extra security, the keypad features a lockout option that will disable the keypad for 30 seconds if 3 consecutive invalid codes are entered. It also has a code time-out feature - if a partial code is entered, the keypad will reset after 15 seconds.

    This model is a slim version that is designed to be surface mounted on a door frame and is laid out in a 2 x 6 matrix. It features screwplugs that prevent removal of the unit from the wall.

  • Resistant to Vandals
  • Resistant to Weather
  • Resistant to Water
  • One-Piece
  • Metal Construction
  • No Moving Parts
  • Piezo Switches
  • Anodized Graphic
  • Tamper-Resistant Mounting

    Model includes:
    Mullion-Style
    Slim
    Surface-Mount
    Green LED
    Red LED
  • Platinum Series Keypad - Aluminum Cover,Outdoor

    The Platinum Series Keypad is made from a solid block of aluminum, this keypad utilizes piezoelectric technology to provide the security installer with the elegance your customer wants and the ruggedness that your customer needs! It is resistant to the effects of Mother Nature and vandals.

    The keypad is a stand-alone unit, requiring only a power supply and electric door lock to operate. Programming is done at the keypad, and it has the capacity to hold over 200 different user codes! Code lengths may be from 4 to 8 digits in length, giving your customer 100 million code combinations! All codes are stored in nonvolatile memory, so if you lose power to the unit, your codes will still be there when power returns.

    To ease the installation, this keypad requires only four (4) wires to install (two for power and two for the lock) and can operate on 12 to 24 Volts DC or 12 Volts AC. For magnetic lock installations, a request-to-exit button can be wired in for fail-safe operation.

    For extra security, the keypad features a lockout option that will disable the keypad for 30 seconds if 3 consecutive invalid codes are entered. It also has a code time-out feature - if a partial code is entered, the keypad will reset after 15 seconds.

    This model is a slim version that is designed to be flush mounted on a door frame and is laid out in a 2 x 6 matrix.

  • Resistant to Vandals
  • Resistant to Weather
  • Resistant to Water
  • One-Piece
  • Metal Construction
  • No Moving Parts
  • Piezo Switches
  • Anodized Graphic
  • Tamper-Resistant Mounting

    Model includes:
    Aluminum Cover
    Outdoor
    Surface Mount
    Green LED
    Red LED
    Night light
  • Corby Industries 1000 - SYSTEM 1 SINGLE DOOR ACCESS CONTROL Corby Industries 1008 - REPLACMENT BOARD FOR SYSTEM 1
    System 1 Single-door Access Control System ● 250 users, 50 event buffer, 3 time schedules, forced entry, door ajar, request-to-exit, serial printer output, non-volatile EEPROM ● 1 main relay, 1 aux relay ● Program with built-in keypad & LED display or full duplex RS232 using PC or VDT ● Keypad, bar code, magnetic stripe, 30-bit Weigand, 30-bit prox, data chip ● Requires 48-4301 for data chip ● Includes transformer, mounting hardware, 50' eight conductor wire ● Does not support 26-bit cards ● Cabinet: 9' W x 12" H x 4.5" D (229mm x 305mm x 114mm)

    Corby Industries 1008 - REPLACMENT BOARD FOR SYSTEM 1

    Corby Industries 11 - 11 GEM BOX WITH TAMPER SWITCH SPDT Corby Industries 12 - 12 SURFACE MOUNT BACK BOX
    Tamper Box ● Recessed ● Single-gang ● Flush mount for old and new work ● Easy-mount swing tabs ● High impact lightweight PVC w/ knockouts ● Tamper switch w/ SPDT form C contacts & leaf-style adjustable contact arm & 6" (152mm) wires attached ● Use with any single-gang device except our 52-4012 71-6522 72-7022 ● Volume is 14 cubic inches ● 2.25" W x 4.125" L x 2.75" D (57mm x 105mm x 70mm) Tamper Box ● Surface mount ● Front tamper switch w/SPDT form C contacts & leaf-style adjustable contact arm & 6" (152mm) wires attached ● One rear tamper form A hermetically sealed plunger type switch with two wires attached ● Use with any single-gang device ● Box is single-gang, surface mount, die cast aluminum painted gray with one-half inch threaded conduit holes (3) ● Mounting hardware included (gaskets not included) ● Volume is 25 cubic inches ● 2.75" W x 4.5" L x 2" D (70mm x 114mm x 51mm)
    Corby Industries 14 - SURFACE MOUNT FOR HEAVY DUTY,METAL KEYPAD Corby Industries 2000 - System 2000 Windows Access Control
    Mounting Box ● Surface mount ● Heavy duty 0.045" thick welded steel with gray corrosion proof coating ● Form A hermetically sealed, plunger type, front mounted tamper switch with two 6" (152mm) wires attached ● Use with any single-gang device ● Front and rear sealing gaskets and mounting hardware included ● Unit has a 0.875"(22 mm) rear hole for exit wiring ● Volume is 18 cubic inches ● 3.31" W x 5.06" L x 1.1" D (84mm x 129mm x 28mm)

    System 2000 Windows Access Control

    Corby's System 2000 controls up to 62 doors and may upgrade to 248. If you need to open one garage door or control an office building, now you can do it.

    The new System 2000 two-door controller is a networked enhanced version of our reliable and field-tested System 2. The System 2000 requires a Network Interface Controller (NIC) and our System 2000 software for Windows. If you already have System 2's installed, they are easily upgraded to System 2000 specifications.

    Users can pass through an entry point secured by a Keypad, Reader, or combination of both by entering a correct code into the Keypad or presenting a valid Card or Data Chip to the reader. The panel then decides if the user is allowed access to this door at the current time and date, either grants or denies access and logs the transaction in the event buffer of the panel and the PCs database.

    A door can be programmed for public access to automatically lock and unlock according to the programmed time schedules set up by the System Administrator. System 2000 has a built-in clock and calendar that automatically adjusts for daylight savings time and leap year. Also, there are hundreds of holidays which allow the System to selectively engage alternate holiday schedules for users and doors.

    Each System panel is equipped with two of the following outputs/inputs: Main Relays, Auxiliary Relays, Voltage Outputs, Door Ajar / Forced Entry Inputs, Request-To-Exit Inputs, Zone Inputs and one Emergency Drop Input.

    Contains the necessary components to install a basic system 2000 package.

    System 2000 NIC
    (Network Controller)
    System 2000 Software
    System 2000 Manual
    Corby Industries 2003 - 1 DR 400USRS BATTRY XFRMR R5232 Corby Industries 2016 - SYS.2/2 DR 3000 USR/R5232 2010
    System 2 ● Single-door Access Control System ● On-site programming w/built-in keypad ● RS-232 port for local programming & monitoring w/VDT or PC or printing ● Up to 424 users per panel ● 8 time schedules, anti-passback, temp users, holidays, door ajar, forced entry, emergency drop inputs, request-to-exit input, zone input ● 1 main relay, 1 aux relay & 1 voltage output ● Supports keypads, data chip, 26 & 30-bit Wiegand & proximity, mag stripe or bar code ● 2nd door option ● Upgradeable to networked System 2000 ● 54-8021 RS-232 to Ethernet Adapter available ● Cabinet: 11" W x 15.5" H x 4.5" D (279mm x 394mm x 114mm)

    System 2 Access Control

    The standard SYSTEM 2 (Model 2016) supports 2700 users and each user can be added or deleted in seconds using the built-in Programming Keypad. The programmable relays can control almost any device including electric Door Locks, arm or disarm Alarm Systems, shunt Alarm Devices, or operate Garage Doors.

    Users can access a secured area using Keypads, Card Readers, or Data Chip Readers. A Request-To-Exit button can be used to exit an area and Magnetic Contacts can be installed to report Door Ajar and Forced Entry conditions. For applications requiring time restriction of users and/or automatic relay operation, 16 time schedules with 1024 time zones are supported.

    Users can pass through an entry point secured by a keypad, reader, or combination of both by entering a correct code into the keypad or presenting a valid card or Data Chip to the reader. The System then decides if the user is allowed access to this door at the current time and date, either grants or denies access and logs the transaction.

    Public access doors can be programmed to automatically lock and unlock according to the programmed time schedules set up by the System Administrator. System 2 has a built-in clock and calendar that automatically adjusts for daylight savings times and leap year. System 2 can be monitored and reports can be printed from an off-site location using dial-up phone modems.

    Each door on the System 2 has two heavy-duty relays and one voltage output. One relay is usually used to lock and unlock a door and the other relay (auxiliary relay) is available for any other purpose. The auxiliary relay and voltage output can be programmed to activate from any System event such as: System Reset, Door Ajar, Memory Clear, Invalid Code, PIN Error, Forced Entry, etc. System 2 also has an emergency 12VDC input which, when activated, will open the normally closed contacts of the door relay(s).

  • Supports 2 Door
  • Expandable to 16 Doors
  • 16 Programmable Time Schedules
  • Brilliant 48 Character Display
  • Expands to Thousands of Users
  • 26 Bit Wiegand Format Capability
  • Off-Site Set-up & Reporting
  • RS485 & RS232 Outputs
  • Forced Entry & Door Ajar
  • Request-To-Exit Input

    This model includes:
    Heavy-Duty Steel Cabinet
    48 Character LCD
    16.5 VAC Class 2 Transformer
    12 V 4 AH Standby Battery
    Installation Manual
  •    
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please