You are here: Home > Shop Brands > Alarm Controls Corp > Panels
We found 2 results matching your criteria.
Sort By:
Page of 1
Alarm Controls 6126NT - 6126 CONTROL PANEL WITH OUT TRANSFORMER. Alarm Controls 6131NT - 6131 WITHOUT TRANSFORMER, SUGGESTED REPLACEMENT FOR 6129
  • Loop status indicator
  • Bell cut-off/automatic reset
  • Regulated voltage output
  • Built-in battery charger
  • Latching panic circuit
  • Remote keyswitch capability
  • Remote loop status capability
  • Dry contacts rated 5 amperes
  • Full static and lighting protection

    Specifications


    Power


    Input: 12 vac, class 2, plug-in transformer, transformer supplied
    Stand-by: 12 volt sealed lead acid battery, 4 a.h. capacity, battery not supplied

    Outputs


    Bell/Siren: 12 vdc, 2.5 apmeres
    Dry contacts: s.p.s.t., normally-open rated amperes @ 28 vdc or 120 vac
    Regulated Voltage: 13.8 vdc, 300 ma., filtered

    Keyswitch


    Maintained contact type, round or flat key, keyswitch not supplied

    Remote leds


    Armed Led: red
    Secure Led: green
    control will accept up to 3 led remote stations

    Adjustable bell cut-off


    Auto restore time: 2 to 15 minutes

    Inputs


    Open circuit instant loop
    Closed circuit Instant loop: maximum loop resistance 1000 ohms
    24 hour latching panic circuit: open circuit, (resets with arming keyswitch)

    Cabinet


    Beige finish, knockout for optional camlock, knockout for cabinet mounted keyswitch,
    secure led, five additional knockouts

    Dimensions


    height 11", width 9", depth 3"



  • The 6131 Panel has all the most wanted features for most installations

  • Adjustable Entry / Exit Delay.
  • Fail Safe Arming
  • Bell Cut-Off, Auto-Restore
  • 24 Hour Latching Panic Circuit
  • Four Wire Remotes
  • Built in Battery Charger
  • Built in Pulse Stretcher
  • Delay Loop Back-Up Circuit
  • Regulated Voltage Output
  • Dry Contacts Rated @ 5A
  • Remote Instant / Delay Switch
  • Full Static & Lightning Protection

    Specifications


    Power


    Input: 12 vac, class 2, plug-in transformer, transformer supplied
    Stand-by: 12 volt sealed lead acid battery, 4 a.h. capacity, battery not supplied

    Outputs


    Bell/Siren: 12 vdc, 2.5 apmeres
    Dry contacts: s.p.s.t., normally-open rated 5 amperes @ 28 vdc or 120 vac
    Regulated Voltage: 13.8 vdc, 300 ma., filtered

    Remote leds


    Armed Led: red
    Secure Led: green
    control will accept up to 3 led remote stations

    Keyswitch


    Momentary type, round or flat key, keyswitch not supplied

    Remote instant/delay switch


    Single pole, single throw, (delay active when open)

    Adjustable bell cut-off


    Auto restore time: 2 to 15 minutes

    Adjustable entry/exit delay


    Entry/exit time: independently adjustable from 2 to 60 seconds

    Inputs


    Open circuit instant loop
    Closed circuit Instant loop: maximum loop resistance 1000 ohms
    Closed circuit delay loop: maximum loop resistance 1000 ohms
    24 hour latching panic circuit: open circuit, (resets with arming keyswitch)

    Cabinet


    Beige finish, knockout for optional camlock, knockout for cabinet mounted keyswitch,
    secure led, five additional knockouts

    Dimensions


    height 11", width 9", depth 3"



  •    
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please