Loop status indicator Bell cut-off/automatic reset Regulated voltage output Built-in battery charger Latching panic circuit Remote keyswitch capability Remote loop status capability Dry contacts rated 5 amperes Full static and lighting protection
Specifications Power Input: 12 vac, class 2, plug-in transformer, transformer supplied Stand-by: 12 volt sealed lead acid battery, 4 a.h. capacity, battery not supplied Outputs Bell/Siren: 12 vdc, 2.5 apmeres Dry contacts: s.p.s.t., normally-open rated amperes @ 28 vdc or 120 vac Regulated Voltage: 13.8 vdc, 300 ma., filtered Keyswitch Maintained contact type, round or flat key, keyswitch not supplied Remote leds Armed Led: red Secure Led: green control will accept up to 3 led remote stations Adjustable bell cut-off Auto restore time: 2 to 15 minutes Inputs Open circuit instant loop Closed circuit Instant loop: maximum loop resistance 1000 ohms 24 hour latching panic circuit: open circuit, (resets with arming keyswitch) Cabinet Beige finish, knockout for optional camlock, knockout for cabinet mounted keyswitch, secure led, five additional knockouts Dimensions height 11", width 9", depth 3"
|
The 6131 Panel has all the most wanted features for most installations Adjustable Entry / Exit Delay. Fail Safe Arming Bell Cut-Off, Auto-Restore 24 Hour Latching Panic Circuit Four Wire Remotes Built in Battery Charger Built in Pulse Stretcher Delay Loop Back-Up Circuit Regulated Voltage Output Dry Contacts Rated @ 5A Remote Instant / Delay Switch Full Static & Lightning Protection Specifications Power Input: 12 vac, class 2, plug-in transformer, transformer supplied Stand-by: 12 volt sealed lead acid battery, 4 a.h. capacity, battery not supplied Outputs Bell/Siren: 12 vdc, 2.5 apmeres Dry contacts: s.p.s.t., normally-open rated 5 amperes @ 28 vdc or 120 vac Regulated Voltage: 13.8 vdc, 300 ma., filtered Remote leds Armed Led: red Secure Led: green control will accept up to 3 led remote stations Keyswitch Momentary type, round or flat key, keyswitch not supplied Remote instant/delay switch Single pole, single throw, (delay active when open) Adjustable bell cut-off Auto restore time: 2 to 15 minutes Adjustable entry/exit delay Entry/exit time: independently adjustable from 2 to 60 seconds Inputs Open circuit instant loop Closed circuit Instant loop: maximum loop resistance 1000 ohms Closed circuit delay loop: maximum loop resistance 1000 ohms 24 hour latching panic circuit: open circuit, (resets with arming keyswitch) Cabinet Beige finish, knockout for optional camlock, knockout for cabinet mounted keyswitch, secure led, five additional knockouts Dimensions height 11", width 9", depth 3"
|