You are here: Home > Shop Brands > Camden Door Controls > Door Activation Devices > Key Switches > Surface Mount Switch Box
We found 13 results matching your criteria.
Sort By:
Page of 2
Camden Marketing CM-1000 Surface Mount Switch Box, SPST Momentary, N/O Camden Marketing CM-1010 Surface Mount Key Switch SPST Maintained
  • Supplied with heavy duty diecast surface box
  • Accepts standard mortise cylinders (1" - 1 1/4")
  • Heavy duty 1/4" thick aluminum plate
  • 1 piece die cast construction
  • Locators prevent cylinder from spinning
  • Cylinder sits flush to faceplate
  • Tamper proof screws provided (No set screws required)
  • Indoor or outdoor applications
  • UL/CSA approved switches
  • 1 or 2 switches may be installed
  • Left and/or right operation
  • Wide range of switch configurations
  • Color coded 18 AWG soldered leads
  • Heat shrink protective sleeve over contacts
  • Casted centre rib protects switches from damage
  • Brushed aluminum finish
  • Custom color finishes and engraving available
  • Optional LED indicators
  • Optional 1-60 second pneumatic time delay.

    *Mortise cylinder sold seperately

  • Surface Mount Switch Box

  • Supplied with heavy duty diecast surface box
  • Accepts standard mortise cylinders (1" - 1 1/4")
  • Heavy duty 1/4" thick aluminum plate
  • 1 piece die cast construction
  • Locators prevent cylinder from spinning
  • Cylinder sits flush to faceplate
  • Tamper proof screws provided (No set screws required)
  • Indoor or outdoor applications
  • UL/CSA approved switches
  • 1 or 2 switches may be installed
  • Left and/or right operation
  • Wide range of switch configurations
  • Color coded 18 AWG soldered leads
  • Heat shrink protective sleeve over contacts
  • Casted centre rib protects switches from damage
  • Brushed aluminum finish
  • Custom color finishes and engraving available
  • Optional LED indicators
  • Optional 1-60 second pneumatic time delay.

    *Mortise cylinder sold seperately

  • Camden Marketing CM-1030 Surface Mount Key Switch SPDT Maintained Silent Knight IntelliKnight 5700 Single Loop Addressable Fire Alarm Control Panel
    Surface Mount Switch Box

  • Supplied with heavy duty diecast surface box
  • Accepts standard mortise cylinders (1" - 1 1/4")
  • Heavy duty 1/4" thick aluminum plate
  • 1 piece die cast construction
  • Locators prevent cylinder from spinning
  • Cylinder sits flush to faceplate
  • Tamper proof screws provided (No set screws required)
  • Indoor or outdoor applications
  • UL/CSA approved switches
  • 1 or 2 switches may be installed
  • Left and/or right operation
  • Wide range of switch configurations
  • Color coded 18 AWG soldered leads
  • Heat shrink protective sleeve over contacts
  • Casted centre rib protects switches from damage
  • Brushed aluminum finish
  • Custom color finishes and engraving available
  • Optional LED indicators
  • Optional 1-60 second pneumatic time delay.

    *Mortise cylinder sold seperately

  • SK-5700 IntelliKnight Model 5700 Single Loop Addressable Fire Alarm Control Panel

    The affordable addressable solution.

    IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system that provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight.

    FEATURES

    • Up to 50 addressable points.

    • Up to 125 zones and 125 output groups.

    • Uses standard wire - no shielded or twisted pair required.

    • Built-in digital communicator.

    • Central Station Reporting by Point or Zone.

    • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC.

    • Distributed, intelligent power.

    • Drift compensation.

    • 13 pre-programmed output cadences, (including ANSI-3.41), and 4 programmable outputs.

    • Notification circuits can be configured as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power.

    • Built-in synchronization for appliances from Gentex®, Faraday, System Sensor®, and Wheelock®.

    • Built-in annunciator with 80-character LCD display.

    • RS-485 bus provides communication to system accessories.

    • Up/Downloading programming, event history, or detector status via remote or direct connection.

    • Built-in RS-232 interface for programming via PC.

    • Built-in Form C trouble relay rated at 2.5 amps at 24 VDC.

    • Two Form C programmable relays rated at 2.5 amps at 24VDC.


    Specifications:
  • Primary AC: 120 VAC, 60 Hz, 1.5A
  • Total Accessory Load: 2.5A @ 27.4 VDC
  • Notification Power: 2.5A@ 27.4 VDC, power-limited
  • Standby Current: 200 mA
  • Alarm Current: 325 mA
  • Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power-limited
  • Battery Charging Capacity: 7.0-35.0 AH
  • Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet.
  • Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm)
  • Weight: 11.5 lbs. (5.2 kg)
  • Color: Red
  • Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required)
  • Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services.
  • Other Approvals: UL Listed; CSFM 7170-0559: 144; MEA 429-92-E Vol. XVI.

    IntelliKnight 5700 Installation and Operation Manual

  • Silent Knight IntelliKnight 5808 Single Loop Addressable Fire Alarm Control Panel Silent Knight SK-4XLM LED Interface Module

    IntelliKnight 5808 Single Loop Addressable Fire Alarm Control Panel

    The convenience of an addressable fire alarm control panel in a cost effective easy to use package.

    The IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system that provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, and easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered to this powerful FACP from Silent Knight.

    The lntelliknight 5808 performs drift compensation and calibration checks on each of the sensors in the system. The basic IntelliKnight 5808 system can be enhanced by adding modules such as the Model 5860 Remote Annunciator, the Model 5824 Serial/Parallel Interface (for printing system reports), and an Intelligent Power Module. The Model 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location.

    FEATURES

    • Up to 127 addressable points.

    • Uses standard wire - no shielded or twisted pair required.

    • Built-in digital communicator.

    • Central Station Reporting by Point or Zone.

    • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC.

    • Distributed, intelligent power.

    • Drift compensation.

    • 13 pre-programmed output cadences, (including ANSI-3.41), and 4 programmable outputs.

    • Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power.

    • Built-in annunciator with 80-character LCD display.

    • RS-485 bus provides communication to system accessories.

    • Built-in RS-232 interface for programming via PC.

    • Built-in Form C trouble relay rated at 2.5 amps at 24 VDC.

    • Two Form C programmable relays rated at 2.5 amps at 24VDC.



    Specifications:
  • Primary AC: 120 VRMS at 50/60 Hz, 2.75A
  • Total Accessory Load: 6A @ 27.4 VDC
  • Notification Power: 6A @ 27.4 VDC, power-limited
  • Standby Current: 170 mA
  • Alarm Current: 325 mA
  • Notification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit, power-limited
  • Battery Charging Capacity: 7.0-35.0 AH
  • Battery Size: 18 AH max. allowed in FACP. Larger capacity batteries can be housed in an RBB accessory cabinet
  • Flush Mount Dimensions: 14.5” W x 24.75” H x 3.5” D (36.8 W x 62.9 H x 8.73 D cm)
  • Overall Dimensions: 16" W x 26.4" H x 4.65" D (40.6 W x 67 H x 11.8 D cm)
  • Weight: 28 lbs. (12.8 kg)
  • Color: Red
  • Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required)
  • Approvals: NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 142; MEA 429-92-E Vol. XIV

    Downloads:

      IntelliKnight 5808 Installation and Operation Manual

  • SK-SK4XLM LED Interface Module

    SK4XLM LED Interface Module

    Silent Knight SK-4XTM Transmitter Module Silent Knight SK-4XZM Zone Relay Module
    SK-SK4XTM Transmitter Module

    SK4XTM Transmitter Module - Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity.

    SK-SK4XZM Zone Relay Module

    SK4XZM Zone Relay Module

    Silent Knight SK-5217 10 Zone Expander for 5208 Silent Knight SK-DP2/4 Dress Panel
    The cost affective way to expand your SK-5208 system

    The Model SK-5217 provides the SK-5208 with ten additional Class B (style B) zones. The SK-5217 can be installed in the SK-5208 control cabinet or remotely (up to 1500 ft.) in a SK-2190 accessory cabinet. The SK-5217 communicates to the SK-5208 control panel via a 4-wire connection to the SBUS.

    SK-5217 Zone Expander
    Adds 10 Class B zone inputs to the SK5208 FACP. Two SK-5217 expanders can be used with the SK-5208 for a total of 30 zones.

    The SK-5217 can be installed in the SK-5208 cabinet or remotely using a SK-2190 accessory cabinet.

    Features
    • Adds 10 zone inputs to the SK-5208 FACP
    • Can be remotely mounted from control (up to 1500 ft.)
    • Easy to install using a 4-wire SBUS connection
    • Supervised
    • UL Listed

    Specifications
    Operating Voltage: 24 VDC Nominal
    Current Draw:
    Max. Total: 1 Amp
    Standby per Zone: 3.0 mA
    Alarm per Zone: 95 mA
    Max. Initiation
    Circuit Resistance: 50W
    Max. Wiring Distance
    From FACP: 1500 ft.
    Operating Temp.: 32° to 120° F (0° to 49° C)
    Humidity: 10 to 85% RH

    SK-DP24 DRESS PANEL

    SK-DP2/4 Dress Panel. Allows access to the panel controls but restricts access to system wiring.

    Channel Vision 2106 BNC Connector Twist-On for RG59 Channel Vision 2129 BNC Female-to-RCA Male Connector 100pc Bag
    Channel Vision's BNC Twist on Type RG59 is a substitute for BNC Crimp on Type RG59 - 2 Piece (2114).

    Channel Vision 2106 BNC twist on type RG59 On sale now for $2 .Channel Vision Technology is a leading manufacturer of innovative technology products in Home Automation, Structured Wiring Systems, Wireless Audio, Multi-Room Audio, Whole House Intercom Systems, Security Cameras and DVR's in both residential and commercial applications.
    These BNC Female to RCA Male Connectors change cables with a male BNC connector into a male RCA connector. This adapter is commonly used to connect different types of audio-video devices together. If you have BNC cables already, this adapter will allow them to be used with video gear which has RCA inputs.

    Specifications:

    Manufacturer: Channel Vision
    Manufacturer Product No.: 2129
    Compatibility: Use to connect RCA connectors with BNC connectors
       
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please