You are here: Home > Shop Brands > Signal Communications > Emergency Communication Systems > DVS+ Voice Evacuation Control Panels
We found 17 results matching your criteria.
DVS Plus panels expand protection, with choices from 50w to 200w. DVS Plus panels offer extended capacities up to 20 selectable loops (Class A/B), 8 selectable alarm tones and 14 distinct messages. Live voice MIC and 25 or 70.7 Vrms option are standard. D
Sort By:
Page of 2
Signal Communications DVA-CAB-PHON-A - TELEPHONE HANDSET STORAGE CABINET FOR FIREFIGHTERS Signal Communications DVA-CAB-PHON-S - TELEPHONE HANDSET STORAGE CABINET

Signal Communications DVA-CAB-PHON-A - TELEPHONE HANDSET STORAGE CABINET FOR FIREFIGHTERS

Signal Communications DVA-CAB-PHON-S - TELEPHONE HANDSET STORAGE CABINET

Signal Communications DVA-RMT-JACK - REMOTE PLUG IN JACK ON SS PLATE Signal Communications DVARMTTEL - REMOTE HAND SET WITH COILED CORD AND PLUG

Signal Communications DVA-RMT-JACK - REMOTE PLUG IN JACK ON SS PLATE

Signal Communications DVARMTTEL - REMOTE HAND SET WITH COILED CORD AND PLUG

Signal Communications DVS-100-12 - 100 WATTS 12 ZONE MICROPHONE, DM PS. Signal Communications DVS-100-4 - 100 WATTS 4 ZONES MIC DM PS
Overview

Effective life safety for many buildings requires improved methods of emergency notification and occupant response. Recognizing this, national, state and local authorities are implementing new requirements for Emergency Voice Alarm systems. Combining audible tones, pre-recorded instructional messages and live voice has proven to enhance occupant awareness, understanding and reaction during an emergency. SigCom’s DVS+ EVAC panels are fully equipped, pre-engineered solutions, designed to meet these requirements.

Description

DVS+ panels include all of the functionality and features required to provide a complete notification and emergency response system. Designed to provide life safety during a fire emergency, DVS+ performs equally well for notification and control of other emergency and non-emergency conditions. Using a modular design DVS+ panels can be configured to meet the specific needs of an installation. Modularity allows modification and expansion to suit changing needs within a building or system.
The DVS+ can provide between 50 and 200 Watts of audio power, field selectable for 25/70.7Vrms operation. Automatic amplifier backup can protect any installed amplifier. Audio output power can be distributed over as many as 20 supervised speaker circuits, field programmed for Class A (Style Z) or Class B (Style Y) wiring. Each amplifier incorporates SigCom’s Intelligent Overload Protection to avoid panel damage without disconnecting the load and disabling the system.
A supervised reverse polarity circuit (NAC), dry contact input or a serial interface can provide the means for DVS+ activation and control. Alarm signals can be automatically or manually directed to selected speaker circuits or to all circuits simultaneously. Eight selectable tones and 2 standard voice messages can be field configured for type, sequence and duration. A total of 14 messages of 30 second duration can be pre-recorded when the DVS-DM8 board is used. Facilities are provided for dual simultaneous messaging. An integral, supervised (Push-To-Talk) microphone is supplied, with the capability for an optional supervised remote microphone. The DVS+ will accept an auxiliary audio input from a telephone page system or similar source.
Every DVS+ panel is pre-engineered, pre-assembled and fully tested.

Features
• 50 To 200 Watts audio power
• Up to 20 supervised speaker loops
• Class A or B wiring, field selectable
• 25 or 70.7 Vrms, field selectable
• 8 selectable alarm tones
• Up to 14 pre-recorded messages,
30 sec. each
• Dual channel capability
• Remote microphone option
• Integral amplifier back-up option
• Integral auxiliary audio input option
• Intelligent amplifier overload protection
• Modular design flexibility

Overview

Effective life safety for many buildings requires improved methods of emergency notification and occupant response. Recognizing this, national, state and local authorities are implementing new requirements for Emergency Voice Alarm systems. Combining audible tones, pre-recorded instructional messages and live voice has proven to enhance occupant awareness, understanding and reaction during an emergency. SigCom’s DVS+ EVAC panels are fully equipped, pre-engineered solutions, designed to meet these requirements.

Description

DVS+ panels include all of the functionality and features required to provide a complete notification and emergency response system. Designed to provide life safety during a fire emergency, DVS+ performs equally well for notification and control of other emergency and non-emergency conditions. Using a modular design DVS+ panels can be configured to meet the specific needs of an installation. Modularity allows modification and expansion to suit changing needs within a building or system.
The DVS+ can provide between 50 and 200 Watts of audio power, field selectable for 25/70.7Vrms operation. Automatic amplifier backup can protect any installed amplifier. Audio output power can be distributed over as many as 20 supervised speaker circuits, field programmed for Class A (Style Z) or Class B (Style Y) wiring. Each amplifier incorporates SigCom’s Intelligent Overload Protection to avoid panel damage without disconnecting the load and disabling the system.
A supervised reverse polarity circuit (NAC), dry contact input or a serial interface can provide the means for DVS+ activation and control. Alarm signals can be automatically or manually directed to selected speaker circuits or to all circuits simultaneously. Eight selectable tones and 2 standard voice messages can be field configured for type, sequence and duration. A total of 14 messages of 30 second duration can be pre-recorded when the DVS-DM8 board is used. Facilities are provided for dual simultaneous messaging. An integral, supervised (Push-To-Talk) microphone is supplied, with the capability for an optional supervised remote microphone. The DVS+ will accept an auxiliary audio input from a telephone page system or similar source.
Every DVS+ panel is pre-engineered, pre-assembled and fully tested.

Features
• 50 To 200 Watts audio power
• Up to 20 supervised speaker loops
• Class A or B wiring, field selectable
• 25 or 70.7 Vrms, field selectable
• 8 selectable alarm tones
• Up to 14 pre-recorded messages,
30 sec. each
• Dual channel capability
• Remote microphone option
• Integral amplifier back-up option
• Integral auxiliary audio input option
• Intelligent amplifier overload protection
• Modular design flexibility

Signal Communications DVS-100-8 - 100 WATTS 8 ZONES MIC DM PS Signal Communications DVS-150-4 - 150 WATT 4 ZONES MIC DM PS
Overview

Effective life safety for many buildings requires improved methods of emergency notification and occupant response. Recognizing this, national, state and local authorities are implementing new requirements for Emergency Voice Alarm systems. Combining audible tones, pre-recorded instructional messages and live voice has proven to enhance occupant awareness, understanding and reaction during an emergency. SigCom’s DVS+ EVAC panels are fully equipped, pre-engineered solutions, designed to meet these requirements.

Description

DVS+ panels include all of the functionality and features required to provide a complete notification and emergency response system. Designed to provide life safety during a fire emergency, DVS+ performs equally well for notification and control of other emergency and non-emergency conditions. Using a modular design DVS+ panels can be configured to meet the specific needs of an installation. Modularity allows modification and expansion to suit changing needs within a building or system.
The DVS+ can provide between 50 and 200 Watts of audio power, field selectable for 25/70.7Vrms operation. Automatic amplifier backup can protect any installed amplifier. Audio output power can be distributed over as many as 20 supervised speaker circuits, field programmed for Class A (Style Z) or Class B (Style Y) wiring. Each amplifier incorporates SigCom’s Intelligent Overload Protection to avoid panel damage without disconnecting the load and disabling the system.
A supervised reverse polarity circuit (NAC), dry contact input or a serial interface can provide the means for DVS+ activation and control. Alarm signals can be automatically or manually directed to selected speaker circuits or to all circuits simultaneously. Eight selectable tones and 2 standard voice messages can be field configured for type, sequence and duration. A total of 14 messages of 30 second duration can be pre-recorded when the DVS-DM8 board is used. Facilities are provided for dual simultaneous messaging. An integral, supervised (Push-To-Talk) microphone is supplied, with the capability for an optional supervised remote microphone. The DVS+ will accept an auxiliary audio input from a telephone page system or similar source.
Every DVS+ panel is pre-engineered, pre-assembled and fully tested.

Features
• 50 To 200 Watts audio power
• Up to 20 supervised speaker loops
• Class A or B wiring, field selectable
• 25 or 70.7 Vrms, field selectable
• 8 selectable alarm tones
• Up to 14 pre-recorded messages,
30 sec. each
• Dual channel capability
• Remote microphone option
• Integral amplifier back-up option
• Integral auxiliary audio input option
• Intelligent amplifier overload protection
• Modular design flexibility

Overview

Effective life safety for many buildings requires improved methods of emergency notification and occupant response. Recognizing this, national, state and local authorities are implementing new requirements for Emergency Voice Alarm systems. Combining audible tones, pre-recorded instructional messages and live voice has proven to enhance occupant awareness, understanding and reaction during an emergency. SigCom’s DVS+ EVAC panels are fully equipped, pre-engineered solutions, designed to meet these requirements.

Description

DVS+ panels include all of the functionality and features required to provide a complete notification and emergency response system. Designed to provide life safety during a fire emergency, DVS+ performs equally well for notification and control of other emergency and non-emergency conditions. Using a modular design DVS+ panels can be configured to meet the specific needs of an installation. Modularity allows modification and expansion to suit changing needs within a building or system.
The DVS+ can provide between 50 and 200 Watts of audio power, field selectable for 25/70.7Vrms operation. Automatic amplifier backup can protect any installed amplifier. Audio output power can be distributed over as many as 20 supervised speaker circuits, field programmed for Class A (Style Z) or Class B (Style Y) wiring. Each amplifier incorporates SigCom’s Intelligent Overload Protection to avoid panel damage without disconnecting the load and disabling the system.
A supervised reverse polarity circuit (NAC), dry contact input or a serial interface can provide the means for DVS+ activation and control. Alarm signals can be automatically or manually directed to selected speaker circuits or to all circuits simultaneously. Eight selectable tones and 2 standard voice messages can be field configured for type, sequence and duration. A total of 14 messages of 30 second duration can be pre-recorded when the DVS-DM8 board is used. Facilities are provided for dual simultaneous messaging. An integral, supervised (Push-To-Talk) microphone is supplied, with the capability for an optional supervised remote microphone. The DVS+ will accept an auxiliary audio input from a telephone page system or similar source.
Every DVS+ panel is pre-engineered, pre-assembled and fully tested.

Features
• 50 To 200 Watts audio power
• Up to 20 supervised speaker loops
• Class A or B wiring, field selectable
• 25 or 70.7 Vrms, field selectable
• 8 selectable alarm tones
• Up to 14 pre-recorded messages,
30 sec. each
• Dual channel capability
• Remote microphone option
• Integral amplifier back-up option
• Integral auxiliary audio input option
• Intelligent amplifier overload protection
• Modular design flexibility

Signal Communications DVS-200-12 - 200 WATT 12 ZONE MIC DM PS Signal Communications DVS-200-16 - 200 WATT 16 ZONE MIC DM
Overview

Effective life safety for many buildings requires improved methods of emergency notification and occupant response. Recognizing this, national, state and local authorities are implementing new requirements for Emergency Voice Alarm systems. Combining audible tones, pre-recorded instructional messages and live voice has proven to enhance occupant awareness, understanding and reaction during an emergency. SigCom’s DVS+ EVAC panels are fully equipped, pre-engineered solutions, designed to meet these requirements.

Description

DVS+ panels include all of the functionality and features required to provide a complete notification and emergency response system. Designed to provide life safety during a fire emergency, DVS+ performs equally well for notification and control of other emergency and non-emergency conditions. Using a modular design DVS+ panels can be configured to meet the specific needs of an installation. Modularity allows modification and expansion to suit changing needs within a building or system.
The DVS+ can provide between 50 and 200 Watts of audio power, field selectable for 25/70.7Vrms operation. Automatic amplifier backup can protect any installed amplifier. Audio output power can be distributed over as many as 20 supervised speaker circuits, field programmed for Class A (Style Z) or Class B (Style Y) wiring. Each amplifier incorporates SigCom’s Intelligent Overload Protection to avoid panel damage without disconnecting the load and disabling the system.
A supervised reverse polarity circuit (NAC), dry contact input or a serial interface can provide the means for DVS+ activation and control. Alarm signals can be automatically or manually directed to selected speaker circuits or to all circuits simultaneously. Eight selectable tones and 2 standard voice messages can be field configured for type, sequence and duration. A total of 14 messages of 30 second duration can be pre-recorded when the DVS-DM8 board is used. Facilities are provided for dual simultaneous messaging. An integral, supervised (Push-To-Talk) microphone is supplied, with the capability for an optional supervised remote microphone. The DVS+ will accept an auxiliary audio input from a telephone page system or similar source.
Every DVS+ panel is pre-engineered, pre-assembled and fully tested.

Features
• 50 To 200 Watts audio power
• Up to 20 supervised speaker loops
• Class A or B wiring, field selectable
• 25 or 70.7 Vrms, field selectable
• 8 selectable alarm tones
• Up to 14 pre-recorded messages,
30 sec. each
• Dual channel capability
• Remote microphone option
• Integral amplifier back-up option
• Integral auxiliary audio input option
• Intelligent amplifier overload protection
• Modular design flexibility

Overview

Effective life safety for many buildings requires improved methods of emergency notification and occupant response. Recognizing this, national, state and local authorities are implementing new requirements for Emergency Voice Alarm systems. Combining audible tones, pre-recorded instructional messages and live voice has proven to enhance occupant awareness, understanding and reaction during an emergency. SigCom’s DVS+ EVAC panels are fully equipped, pre-engineered solutions, designed to meet these requirements.

Description

DVS+ panels include all of the functionality and features required to provide a complete notification and emergency response system. Designed to provide life safety during a fire emergency, DVS+ performs equally well for notification and control of other emergency and non-emergency conditions. Using a modular design DVS+ panels can be configured to meet the specific needs of an installation. Modularity allows modification and expansion to suit changing needs within a building or system.
The DVS+ can provide between 50 and 200 Watts of audio power, field selectable for 25/70.7Vrms operation. Automatic amplifier backup can protect any installed amplifier. Audio output power can be distributed over as many as 20 supervised speaker circuits, field programmed for Class A (Style Z) or Class B (Style Y) wiring. Each amplifier incorporates SigCom’s Intelligent Overload Protection to avoid panel damage without disconnecting the load and disabling the system.
A supervised reverse polarity circuit (NAC), dry contact input or a serial interface can provide the means for DVS+ activation and control. Alarm signals can be automatically or manually directed to selected speaker circuits or to all circuits simultaneously. Eight selectable tones and 2 standard voice messages can be field configured for type, sequence and duration. A total of 14 messages of 30 second duration can be pre-recorded when the DVS-DM8 board is used. Facilities are provided for dual simultaneous messaging. An integral, supervised (Push-To-Talk) microphone is supplied, with the capability for an optional supervised remote microphone. The DVS+ will accept an auxiliary audio input from a telephone page system or similar source.
Every DVS+ panel is pre-engineered, pre-assembled and fully tested.

Features
• 50 To 200 Watts audio power
• Up to 20 supervised speaker loops
• Class A or B wiring, field selectable
• 25 or 70.7 Vrms, field selectable
• 8 selectable alarm tones
• Up to 14 pre-recorded messages,
30 sec. each
• Dual channel capability
• Remote microphone option
• Integral amplifier back-up option
• Integral auxiliary audio input option
• Intelligent amplifier overload protection
• Modular design flexibility

Signal Communications DVS-AM50 - 50 WATT DUAL CHANNEL AMPLIFIER Signal Communications DVS-CM1 - CONTROLLER BOARD
Each DVS-AM50 Amplifier Module is capable of delivering a single 50 Watt output or dual channels of 25W each, 25/70.7 Vrms (programmable). Amplifier outputs can be direct wired (Style Y or Z programmable) to system speakers or multiple zones via DVS-ZM4 Zone Boards. A DVS+ panel can include up to four 50W Amplifier Modules for a total of 200 Watts of audio power. A backup Amplifier can be configured to backup any other amplifier. The DVS-CM1 Controller Board is the heart of the system, providing control and interface circuits to operate the DVS+ panel. The Controller Board incorporates the primary digital message circuit that generates emergency alarm/alert tones and pre-recorded messages. An integral, supervised local microphone can be used during system standby for normal paging or to override the pre-recorded messaging during alarm. Announcements can be made selectively to individual zones or “ALL CALL”. The DVS-CM1 provides the interfaces for a DVS-DM8 Auxiliary Digital Message Board, an auxiliary audio input and the optional Remote Microphone.
   
 
 
 

Enter your email for a chance to WIN $100 Amex Gift Card.

Please Enter Your Email Address

*One entry per household please