Sophisticated Performance at Low Cost
The new Fire-Lite MS-5UD-3, five zone, and MS-10UD-7, ten zone, conventional fire control panels have features normally found in more expensive addressable systems.
Key features include:
FL-MS10UD7 / MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet).
The Fire-Lite MS-2 and MS-2E Fire Alarm Control Panels bring the latest in microprocessor technology to conventional fire controls. The MS-2 is compatible with the new i³ smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using three selections for manufacturer protocol. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires. The MS-2 also is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally- open contact devices. For 240 VAC operation, order MS-2E. See the FireLite Device Compatibility Document 15384 for a complete list of compatible devices. NOTE: Unless indicated otherwise, the term MS-2 refers to both MS-2 and MS-2E models.
FEATURES Two Style B (Class B) IDCs (Initiating Device Circuits). One Style Y (Class B) NAC (Notification Appliance Circuit). 24 VDC. i³ Technology features: Drift compensation automatically adjusts detector sensitivity and increases resistance to false alarms caused by dust accumulation. Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. Wireless handheld sensitivity meter eliminates the need for voltmeters, magnets and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication. Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing. Special test protocol and LED indication allows quick test of all detectors without need for a ladder. NAC synchronization features: Provides synchronization of standard ANSI audible signals as required by NFPA 72. Provides synchronization of ADA compliant strobes per NFPA 72. Selectable for System Sensor, Wheelock and Gentex protocols. Selective Silence feature allows manual silence of horns while strobes continue to flash on the same NAC. Silent or Audible Walk Test operation mode commanded from the front keypad, with automatic return to normal after one hour of inactivity. Alarm verification selectable per zone. Each zone may be programmed for supervisory or fire, with separate red and yellow LEDs. Disable switches provided per zone. NACs programmable for: Silence Inhibit Auto Silence Strobe Synchronization Selective Silence (horn-strobe mute) Temporal or Steady signal Silenceable or Nonsilenceable Form-C Alarm and Trouble relays. 3.0 amps total usable current. Optional dress panel (P/N DP-MS2/4).
REPLACES FL-MS4424
GENThe FireLite MS-4 and MS-4E Fire Alarm Control Panels bring the latest in microprocessor technology to conventional fire controls. The MS-4 is compatible with the i³ smoke detectors from System Sensor, and provide such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using three selections for manufacturer protocol. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.
The MS-4 also is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. For 240 VAC operation, order MS-4E. See the FireLite Device Compatibility Document 15384 for a complete list of compatible devices. NOTE: Unless indicated otherwise, the term MS-4 refers to both MS-4 and MS-4E models.
FEATURES Four Style B (Class B) IDCs (Initiating Device Circuits). Two Style Y (Class B) NACs (Notification Appliance Circuits). Optional module that converts all four IDCs and two NACs to Class A. 24 VDC. i³ Technology features: Drift compensation automatically adjusts detector sensitivity and increases resistance to false alarms caused by dust accumulation. Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. Wireless hand-held sensitivity meter eliminates the need for voltmeters, magnets and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication. Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing. Special test protocol and LED indication allows quick test of all detectors without need for a ladder. NAC synchronization features: Provides synchronization of standard ANSI audible signals as required by NFPA 72. Provides synchronization of ADA compliant strobes per NFPA 72. Selectable for System Sensor, Wheelock and Gentex protocols. Selective Silence feature allows manual silence of horns while strobes continue to flash on the same NAC. Silent or Audible Walk Test operation mode commanded from the front keypad, with automatic return to normal after one hour of inactivity. Programmable for combination tamper supervisory monitor and waterflow alarm on one zone. Alarm verification selectable per zone. Each zone may be programmed for supervisory or fire, with separate red and yellow LEDs. Disable switches provided per zone. NACs programmable for: Silence Inhibit Auto Silence Strobe Synchronization Selective Silence (horn-strobe mute) Temporal or Steady signal Silenceable or Nonsilenceable Form-C Alarm, Trouble and Supervisory relays. 3.0 A total usable current. 6.0 A total usable current available with optional second transformer. Optional dress panel (P/N DP-MS2/4).
REPLACES FL-MS4424 FL-MS4424B
FL-MS5UD3 / MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet).
Sophisticated Performance at the Cost of a Conventional System. The MS-9050UD Fire Alarm Control Panel offers state-of-the-art technology with easy installation, operation, and maintenance. Suited for stand-alone applications, the MS-9050UD is ideal for smaller facilities such as apartment complexes, banks, cinemas, child care and elementary schools, department stores, food stores, places of worship, restaurants, small retail outlet stores, and other facilities requiring performance-based, sophisticated technology at reasonable cost.
With capabilities such as remote upload/download programming and diagnostics, addressable point identification, drift compensation, built-in digital communication, and NAC synchronization, the MS-9050UD delivers features typically found only in more expensive, larger systems.
High Performance with Remarkable Flexibility. The panel supports a wide range of addressable sensors, control outputs, and notification devices capable of meeting the most challenging design specifications. With support for up to 50 addressable points of any type on a single SLC loop, the MS-9050UD provides advanced addressable features at a price that competes with conventional systems.
With an integrated Digital Alarm Communicator Transmitter (DACT) for off-premises monitoring and remote Upload/Download programming support, the MS-9050UD is a compact Fire Alarm Control Panel that provides large system technology with remarkable flexibility.
Standard Colors and Messages:
You can have anything you wanted printed, provided it fits. There are no returns on custom printed product.
This North American style, multipurpose push button switch and clear Bopper Stopper cover protect a wide range of applications indoors. The button incorporates a unique, patented design and the clear cover helps prevent accidental activation. The highly advanced Stopper Station push button unit is ADA compliant. The button incorporates a unique, patented design that helps dramatically to stop accidental activation. Molded unit has key to reset button. The Bopper Stopper cover can take hard knocks in stride while protecting important devices. It's molded of super tough polycarbonate material. Features: