You are here: Home > Shop Brands > Camden Door Controls > Door Activation Devices > Accessories > Pressure Gauges
We found 19 results matching your criteria.
Sort By:
Page of 2
Camden CM-PG2 0-35 LB Pressure Gauge Wheelock 126097 - HORN STROBE WEATHERPROOF WORDING AGENT RED

0-35 LB Pressure Gauge

Used to measure the opening and closing force of automatic doors, manual door closers, or garage doors.

The ideal tool to ensure compliance with ADA, ANSI and similar standards.

Features:
  • Use PG-2 to measure auto door opening force (swinging, sliding or overhead)

Wheelock 126097 - HORN STROBE WEATHERPROOF WORDING AGENT RED

Wheelock AMT-12/24-W - AMT ALARM WHITE 12/24DC Wheelock AS-24MCC-FR - AS-24MCC-FR MULTI CD CEILING RED PLATE H/S  REPLACES 127411, 127400, 127401, 127402, 127403
Description:
The Wheelock Series AMT Multiple Input Electronic Appliances provide the industry with a UL Standard 1971 and UL Standard 464 combination audible/visual device that simplifies installation and offers three (3) distinct prioritized audible signals from three isolated inputs. Priority (1) will override all other commands upon activation.
The AMT offers a choice of eight (8) self-prioritized sound combinations for suppression releasing systems, combination security and emergency evacuation systems and high risk installations as well as many other applications.
The AMT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72 (the National Fire Alarm Code), ANSI 117.1 (the American National Standard For Accessible and Usable Buildings and Facilities) and UL Standard 1971 (Standard for Signaling Devices for the Hearing Impaired).
Each AMT Audible and AMT Strobe appliance has two user selective sound output levels: STANDARD dBA and HIGH dBA. The AMT Audible provides 12VDC or 24VDC operation, filtered or FWR. The AMT Strobe Electronic Appliances operate at 24VDC and may be used with filtered or unfiltered (full-wave-rectified) input voltages. Separate supervised sets of input terminals are available for each prioritized input. Jumper plugs are provided to enable both tone and strobe to operate simultaneously for all inputs.
The AMT Multitone Strobe Appliances are UL Listed for indoor use, wall mount, under Standard 1971 for Signaling Devices for the Hearing Impaired and Standard 464 for Audible Signal Appliances, and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visible signaling.

Features:
• Approvals include: UL Standard 1971, UL Standard 464 and New York City (MEA) ULC
• Compliance with RFI limits in FCC Part 15, Class B for compatibility with sensitive detection and communication circuits
• Designed to meet or exceed NFPA/ANSI Standards and ADA Accessibility Guidelines. Meets OSHA 29 Parts 1910.165
• Three separate prioritized inputs that will activate three isolated signals
• All inputs are supervised
• Code-3 Horn and Tone meet ANSI/NFPA/ISO temporal pattern.
• Two power taps for high dBA and standard dBA @ 10 feet
• Low current draw with low temperature compensation to reduce power consumption and wiring costs
• AMT Strobe models available with 15/75 and 75 candela ratings for independent or combination input activations
• AMT with strobe can flash independently or in unison with all audible signals
• 12VDC and 24VDC models with wide listed voltage range, filtered (DC) and FWR. (AMT Strobe version in 24 volts only.)
• Polarized inputs for compatibility with standard reverse polarity type supervision of circuit wiring by an alarm panel
• Low cost installation via standard electrical boxes. Attractive flush or surface mounting options
• No additional trimplate required for flush mounting. Fast installation with In/Out screw terminals using #12 to #18 AWG


Description
The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw.
Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd.
Ceiling mount models incorporate Wheelock’s patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd.
The audible provides a selectable choice of either a
continuous horn or temporal pattern (Code 3) when
constant voltage from a Fire Alarm Panel (FACP) is
applied. Each tone has 3 dBA settings to choose from.
When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-24-8MC Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire.

Features
• Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information
• ADA/NFPA/UFC/ANSI Compliant
• Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model)
• Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multi-candela ceiling models)
• Selectable Continuous Horn or Temporal (Code 3).
• 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones
• Patented 2-Wire Audible Strobe Appliance.
• Patented Universal Mounting Plate
• Weatherproof models are available for outdoor use
• Strobes produce 1 flash per second over the regulated voltage range
• 12 and 24 VDC models with wide UL “Regulated Voltage Range” using filtered DC or unfiltered FWR input voltage
• The strobes can be synchronized using Wheelock’s sync modules or power supplies with built in sync protocol
• Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires

Wheelock AS-24MCW-FR Wall-Mount Horn Strobe (red) Wheelock ASWP-2475C-FR - WEATHERPROOF HORN STROBE CEILING MOUNT RED 24 VOLT
These Wheelock horn-strobes are two-wire devices that provide strobe choices of 15 cd, 30 cd, 75 cd, or 95 cd (MCC ceiling-mount models) or 15 cd, 30 cd, 75 cd, or 110 cd (MCW wall-mount models). They offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the fire alarm control panel (FACP) is applied. Each tone has three volume levels that can be selected at installation (field-selectable). These horn-strobes can be synchronized with the SM (single) and DSM (dual) modules or a compatible control panel. The audible response can be silenced while maintaining strobe activation, a requirement in some jurisdictions.
  • 24 VDC, filtered or unfiltered
  • Wall mount (MCW models) or ceiling mount (MCC models)
  • Selectable continuous horn or temporal (Code 3) tones each with three selectable volume settings
  • Synchronize with SM and DSM modules
  • Cost-efficient two-wire operation with low profile design
  • ADA, NFPA, ANSI compliant
  • Designed for life safety, performance and reliability, Cooper Wheelock’s cost effective weatherpoof notification appliances include:
    Weatherproof Appliances Series
    Strobes: SSWP
    Horn Strobes: ASWP
    Horns: AH-24WP, AH-12WP
    Multitone Horn Strobes: MTWP
    Multitone Horns: MT
    Speaker Strobes: ET70WP
    Speakers: ET-1010
    All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of –31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting).
    To enable weatherproof mounting, Cooper-Wheelock provides the industry’s widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (IOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories.
    When used in conjunction with Wheelock PS-24-8MC Power Supplies or SM/DSM Sync Modules, the Wheelock weatherproof appliances can be synchronized to meet NFPA 72 synchronization requirements. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones.

    Features:
    • Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP) . See agency approvals by model number on page two of this document
    • Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA
    • Weatherproof with extended temperature range of –40°F to 150°F (-40°C to 66°C)*
    • Dual Listed strobe models (UL 1638 and UL 1971)
    • Industry’s highest strobe candela options
    • Synchronization capability using Series SM, DSM Synch Modules (MTWP and MT-12/24 audible is non-sync)
    • Models with field selectable tone, dBA and candela settings
    • Wall or ceiling mounting options
    • Surface of semi-flush mounting
    • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal


    Candela Ratings

    Series

    UL 1971

    UL 1638 @ 77°F

    UL 1638 @ -40°F

    RSS, ET70WP and MTWP UL Max Current (Strobe Only)

    ASWP

    @ 32º-120ºF

    High

    Med

    Low

    2475

    30

    180

    115

    0.138

    0.168

    0.155

    0.15

    MCWH

    135

    135

    65

    0.3

    0.355

    0.34

    0.335

    185

    185

    90

    0.42

    0.48

    0.465

    0.46

    MCCH

    115

    115

    50

    0.3

    0.355

    0.34

    0.335

    177

    177

    75

    0.42

    0.48

    0.465

    0.46

    24185

    185

    185

    90

    0.42

     

    24177

    177

    177

    75

    Wheelock ASWP-2475C-FW - HORN STROBE WHITE WEATHERPROOF Wheelock MTWP-2475C-FR - OUTDOOR HORN STROBE CEILING MOUNT 75CD 24 VOLTS
    Designed for life safety, performance and reliability, Cooper Wheelock’s cost effective weatherpoof notification appliances include:
    Weatherproof Appliances Series
    Strobes: SSWP
    Horn Strobes: ASWP
    Horns: AH-24WP, AH-12WP
    Multitone Horn Strobes: MTWP
    Multitone Horns: MT
    Speaker Strobes: ET70WP
    Speakers: ET-1010
    All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of –31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting).
    To enable weatherproof mounting, Cooper-Wheelock provides the industry’s widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (IOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories.
    When used in conjunction with Wheelock PS-24-8MC Power Supplies or SM/DSM Sync Modules, the Wheelock weatherproof appliances can be synchronized to meet NFPA 72 synchronization requirements. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones.

    Features:
    • Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP) . See agency approvals by model number on page two of this document
    • Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA
    • Weatherproof with extended temperature range of –40°F to 150°F (-40°C to 66°C)*
    • Dual Listed strobe models (UL 1638 and UL 1971)
    • Industry’s highest strobe candela options
    • Synchronization capability using Series SM, DSM Synch Modules (MTWP and MT-12/24 audible is non-sync)
    • Models with field selectable tone, dBA and candela settings
    • Wall or ceiling mounting options
    • Surface of semi-flush mounting
    • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal


    Candela Ratings

    Series

    UL 1971

    UL 1638 @ 77°F

    UL 1638 @ -40°F

    RSS, ET70WP and MTWP UL Max Current (Strobe Only)

    ASWP

    @ 32º-120ºF

    High

    Med

    Low

    2475

    30

    180

    115

    0.138

    0.168

    0.155

    0.15

    MCWH

    135

    135

    65

    0.3

    0.355

    0.34

    0.335

    185

    185

    90

    0.42

    0.48

    0.465

    0.46

    MCCH

    115

    115

    50

    0.3

    0.355

    0.34

    0.335

    177

    177

    75

    0.42

    0.48

    0.465

    0.46

    24185

    185

    185

    90

    0.42

     

    24177

    177

    177

    75

    Designed for life safety, performance and reliability, Cooper Wheelock’s cost effective weatherpoof notification appliances include:
    Weatherproof Appliances Series
    Strobes: SSWP
    Horn Strobes: ASWP
    Horns: AH-24WP, AH-12WP
    Multitone Horn Strobes: MTWP
    Multitone Horns: MT
    Speaker Strobes: ET70WP
    Speakers: ET-1010
    All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of –31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting).
    To enable weatherproof mounting, Cooper-Wheelock provides the industry’s widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (IOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories.
    When used in conjunction with Wheelock PS-24-8MC Power Supplies or SM/DSM Sync Modules, the Wheelock weatherproof appliances can be synchronized to meet NFPA 72 synchronization requirements. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones.

    Features:
    • Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP) . See agency approvals by model number on page two of this document
    • Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA
    • Weatherproof with extended temperature range of –40°F to 150°F (-40°C to 66°C)*
    • Dual Listed strobe models (UL 1638 and UL 1971)
    • Industry’s highest strobe candela options
    • Synchronization capability using Series SM, DSM Synch Modules (MTWP and MT-12/24 audible is non-sync)
    • Models with field selectable tone, dBA and candela settings
    • Wall or ceiling mounting options
    • Surface of semi-flush mounting
    • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal


    Candela Ratings

    Series

    UL 1971

    UL 1638 @ 77°F

    UL 1638 @ -40°F

    RSS, ET70WP and MTWP UL Max Current (Strobe Only)

    ASWP

    @ 32º-120ºF

    High

    Med

    Low

    2475

    30

    180

    115

    0.138

    0.168

    0.155

    0.15

    MCWH

    135

    135

    65

    0.3

    0.355

    0.34

    0.335

    185

    185

    90

    0.42

    0.48

    0.465

    0.46

    MCCH

    115

    115

    50

    0.3

    0.355

    0.34

    0.335

    177

    177

    75

    0.42

    0.48

    0.465

    0.46

    24185

    185

    185

    90

    0.42

     

    24177

    177

    177

    75

    Wheelock 120200 Horn Strobe Weatherproof 75CD No Lettering Red Wheelock 125743 Multi Tone 24V Wall Unit Red "Agent"
    Review and buy the Wheelock 120200 Horn Strobe Weatherproof 75CD No Lettering Red made by Wheelock in our Wheelock section. Find other Wheelock products at SecurityStoreUSA.com Review and buy the Wheelock 125743 - Multi Tone 24V Wall Unit Red "Agent" made by Wheelock in our Audible Strobe Appliances section. Find other Audible Strobe Appliances products at SecurityStoreUSA.com
    Wheelock AH-24WP-R 24 VDC Weatherproof Electronic Horn (Red) Wheelock AMT-12/24-R AMT Alarm Red 12/24DC
    These Wheelock horns offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable volume levels. These horns can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns might overlap and not be distinctive. The Wheelock Series AMT Multiple Input Electronic Appliances provide the industry with a UL Standard 1971 and UL Standard 464 combination audible visual device that simplifies installation and offers three (3) distinct prioritized audible signals from three isolated inputs. Priority (1) will override all other commands upon activation.

    The AMT offers a choice of eight (8) self-prioritized sound combinations for suppression releasing systems, combination security and emergency evacuation systems and high risk installations as well as many other applications.

    The AMT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72 (the National Fire Alarm Code), ANSI 117.1 (the American National Standard For Accessible and Usable Buildings and Facilities) and UL Standard 1971 (Standard for Signaling Devices for the Hearing Impaired).

    Each AMT Audible and AMT Strobe appliance has two user selective sound output levels: STANDARD dBA and HIGH dBA. The AMT Audible provides 12VDC or 24VDC operation, filtered or FWR. The AMT Strobe Electronic Appliances operate at 24VDC and may be used with filtered or unfiltered (full-wave-rectified) input voltages. Separate supervised sets of input terminals are available for each prioritized input. Jumper plugs are provided to enable both tone and strobe to operate simultaneously for all inputs.

    The AMT Multitone Strobe Appliances are UL Listed for indoor use, wall mount, under Standard 1971 for Signaling Devices for the Hearing Impaired and Standard 464 for Audible Signal Appliances, and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan lens to provide maximum reliability for effective visible signaling.
       
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please