You are here: Home > Catalog > Demo Kits
We found 60 results matching your criteria.

McAfee Secure sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams

Demo Kits

  Accessories
  Controls
  Keypads
Accessories
Controls
Keypads
Sort By:
Page of 5
Fire-Lite ACC-25/50DAZS Distributed Audio panel 25 Watt, 25 Vrms w/ Zone SPlitter Fire-Lite BAT-12120: Battery, 12 volt, 12.0 AH
ACC-25/50DAZS Single channel, 25 Watt, 25 Vrms, emergency voice evacuation panel. Can be automatically activated via the Zone System serial communication link from the ACC-25/50ZS.

GENERAL INFORMATION
The FireLite ACC-25/50DAZS is a state-of-the-art, compact, DA (Distributed Audio) panel which is designed to interface directly to addressable or conventional fire alarm control panels or can be automatically activated via the Audio Command Center25/50 (ACC-25/50) Series' Zone System serial communications link. The ACC-25/50DAZS is offereed in a self-contained, cost effective modular design that includes a single channel, 25 Watt, 25 Vrms audio amplifier, a zone page module (ACC-APM), and a zone splitter module (ACC-ASM). The additional optional digital message generator module provides a factory-prerecorded voice announcement and field record and playback capability.

The ACC-25/50DA, which supports up to eight speaker circuits, can be used to distribute voice evacuation audio over a building's speaker system. The audio riser input provides automatic gain control (AGC) which compensates for any sudio signal loss due to circuit loading or cable length, to ensure delivery of a full output signal to the speakers. The built-in power supply and battery charger provides up to 18 AH for systems requiring 24-hour bacup. Other options include a 25 Watt, 25 Vrms audio amplifier for system expansion to 50 Watts (providing dual 25 Watt speaker circuits) or as a secondary, backup amplifier. A 70.7 Vrms converter is also available for independently converting amplifier to meet retrofit needs. Suitable applications include, but are not limited to: schools, auditoriums, dormitories, theaters, restaurants, places of worship, motels/hotels, office buildings, factories, etc.

Features :

  • 25 watts of 25 Vrms audio power (Expandable to 50 watts) per panel.
  • Up to four Style Z or eight Style Y speaker circuits with use of optional zone splitter module (ACC-ZSM).
  • Automatic gain control (AGC).
  • Optional 70.7 Vrms conversion module available for each amplifier.
  • Integral primary AC power supply or secondary battery charging circuit.
  • Designed for maximum system flexibility and expansion.
  • Unobstructed module access and removable terminal blocks for ease of service and maintenance.
  • Optional digital message generator module (FC-MGM) with factory-prerecorded emergency evacuation message or custom 60-second recorded message capacity.
  • Five Command Input Circuits.
  • Field-selectable message and field recording capability using optional FC-MGM's RCA jack or mini audio input jack for connection to a personal computer.
  • Built-in alert tone generators with steady, slow whooop, high/low or chime tones.
  • Integral diagnostic LEDs include: Power, System Trouble, ALARM,
  • Message Generator Trouble, Tone Generator Trouble, Amplifier Fault and others.
  • Independent Form-C trouble relay allows FACP to monitor voice system while in active (alarm) state. 35 mA Special Application auxiliary power output for addressable modules and End-of-Line power supervision.
  • Optional lock playback speaker for use with optional message generator module.
  • Can be controlled by the ACC-25/50ZS via the Zone System serial link (EIA-485) to the ACC-ZPM.
  • FL-BAT12120 / REPLACES FL-PS12120

    BAT-12120: Battery, 12 volt, 12.0 AH, (two required for stand-alone applications; requires BB-17F Battery Box.)

    Fire-Lite BAT-12180: Battery, 12 volt, 18.0 AH Fire-Lite BAT-1270 battery, 12 volt, 7.0 AH
    FL-BAT12180 / BAT-12180: Battery, 12 volt, 18.0 AH, (two required for stand-alone applications. BAT-1270: battery, 12 volt, 7.0 AH
    Fire-Lite CMF300 Control Module Fire-Lite DP-51050: Optional dress panel
    The CMF-300 and CRF-300 Addressable Control Modules are used with Fire•Lite's Addressable Fire Alarm Control Panels. These addressable control modules provide Notification Appliance Circuits (CMF-300) and Form-C Output Relay (CRF-300).

    The CMF-300 Addressable Control Module provides Fire-Lite Alarm's MS-9200 and MS-9600 intelligent control panels.

    DP-51050: Optional dress panel. Restricts access to the system wiring while allowing access to the membrane switch panel.
    Fire-Lite FCPS-24FS6 (6 amps/4 NACs/Built In Sync) Fire-Lite FCPS-24FS8 (8 amps/4 NACs/Built In Sync)

    FCPS-24FS6 Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions.

    The FCPS-24FS6 is a compact, cost-effective, 6-amp remote power supply with battery charger. The FCPS-24FS6 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS6 also contains a battery charger capable ofcharging up to 18 Amp Hour batteries.

    FEATURES
    • UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex appliances.
    • Cascadable up to 10 power supplies with strobe timing maintained.
    • Operates as a sync follower or a sync generator (default).
    • Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode]).
    • Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF-300) for alarm activation.
    • Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits.
    • 6 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864).
    • 4 Amp continuous output in stand-alone mode (UL 1481).
    • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two.
    • Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power).
    • Power-limiting technology meets UL power-limiting requirements.
    • Form-C normally-closed trouble relay.
    • Fully supervised power supply, battery and Notification Appliance Circuits.
    • Selectable earth fault detection.
    • AC trouble report selectable for immediate or 8 hour delay.
    • Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power).
    • Requires input trigger voltage of 9.0 - 32 VDC.
    • Self-contained in compact, lockable cabinet (15" [381 mm] H x 14.5" [368 mm] W x 2.75" [70 mm] D).
    • Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries.
    • Battery charger may be disabled via dip switch for applications requiring larger batteries.
    • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.25 mm²) wire.

    The FCPS-24FS8 is a compact, cost-effective, 8-amp remote power supply with battery charger. The FCPS-24FS8 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization or auxiliary power to support 24-volt system accessories. The FCPS-24FS8 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS8 also contains a battery charger capable of charging up to 18 Amp Hour batteries.

    FEATURES
    • UL Listed NAC Synchronization using System Sensor, Wheelock, or Gentex appliances.
    • Cascadable up to 10 power supplies with strobe timing maintained.
    • Operates as a sync follower or a sync generator (default).
    • Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode]).
    • Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation.
    • Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits.
    • 8 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864).
    • 6 Amp continuous output in stand-alone mode (UL 1481).
    • Compatible with coded inputs; signals passed through.
    • Optional power supervision relay (A77-716B)
    • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two.
    • Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power).
    • Power-limiting technology meets power-limiting requirements.
    • Normally-closed trouble contact.
    • Fully supervised power supply, battery and Notification Appliance Circuits.
    • Selectable earth fault detection.
    • AC trouble report selectable for immediate or 8 hour delay.
    • Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power).
    • Requires input trigger voltage of 9.0 - 32 VDC.
    • Self-contained in compact, lockable cabinet (15" [381 mm] H x 14.5" [368 mm] W x 2.75" [70 mm] D).
    • Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries.
    • Battery charger may be disabled via dip switch for applications requiring larger batteries.
    • Fixed, clamp-type terminal blocks accommodate up to12 AWG (3.25 mm²) wire.

    Fire-Lite IPENC External mounting enclosure for IPDACT Fire-Lite MRP-4424 (C/E) 4-Zone, 24 VDC Agent Releasing Panel
    IPENC: External mounting enclosure consisting of mounting bracket IPBRKT, ground wire/lug and screws. Enclosure must be “close-nipple” to a panel no further than 6 in. (15 cm) via conduit. The MRP-4424(C/E) is a 24-volt, Agent Release Control Panel. Compact and cost-effective, the MRP-4424 is powerful, offering a variety of options designed to meet most low-end releasing applications. (C)= Canadian
    Fire-Lite SD355 Addressable PhotoElectric Smoke w/Base Fire-Lite SD355T Addressable PhotoElectric Smoke w/ Thermal Element

    The SD355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's MS-9200, MS-9200UD, and MS-9600 Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).

    Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z).

    Features
    • SLC loop:
      • Two-wire loop connection.
      • Unit uses base for wiring.
    • Addressing:
      • Addressable by device.
      • Direct Decade 01 – 99 (MS-9200, MS-9200UD) and 01 – 159 (MS-9600) entry of address.
    • Architecture:
      • Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires.
      • Sleek, low-profile design.
      • Integral communications and built-in type identification.
      • Built-in tamper-resistant feature.
      • Removable cover and insect-resistant screen for simple field cleaning.
    • Operation:
      • Withstands air velocities up to 1,500 feet-per-minute (7.6 m/sec.) without triggering a false alarm.
      • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level.
      • Visible LED “blinks” when the unit is addressed (communicating with the fire panel) and latches on in alarm.
    • Mechanicals:
      • Sealed against back pressure.
      • Direct surface mounting or electrical box mounting.
      • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included).

    The SD355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's MS-9200, MS-9200UD, and MS-9600 Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).

    Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z).

    Features
    • SLC loop:
      • Two-wire loop connection.
      • Unit uses base for wiring.
    • Addressing:
      • Addressable by device.
      • Direct Decade 01 – 99 (MS-9200, MS-9200UD) and 01 – 159 (MS-9600) entry of address.
    • Architecture:
      • Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires.
      • Sleek, low-profile design.
      • Integral communications and built-in type identification.
      • Built-in tamper-resistant feature.
      • Removable cover and insect-resistant screen for simple field cleaning.
    • Operation:
      • Withstands air velocities up to 1,500 feet-per-minute (7.6 m/sec.) without triggering a false alarm.
      • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level.
      • Visible LED “blinks” when the unit is addressed (communicating with the fire panel) and latches on in alarm.
    • Mechanicals:
      • Sealed against back pressure.
      • Direct surface mounting or electrical box mounting.
      • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included).
       
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please