Demo Kits
GENERAL INFORMATION The Fire-Lite ACC-25/50DA is a state-of-the-art, compact, DA (Distributed Audio) panel which is designed to interface directly to addressable or conventional fire alarm control panel or with the Audio Command Center-25/50 (ACC-25/50) Series audio panels. The ACC-25/50DA is offered in a self-contained, cost-effective modular design that includes a single channel, 25 Watt, 25 Vrms audio amplifier. Additionally, an optional digital message generator module provides a factory-prerecorded voice announcement and field record and playback capability. The ACC-25/50DA, which supports up to eight speaker circuits, can be used to distribute voice evacuation audio over a building's speaker system. The audio riser input provides automatic gain control (AGC) which compensates for any sudio signal loss due to circuit loading or cable length, to ensure delivery of a full output signal to the speakers. The built-in power supply and battery charger provides up to 18 AH for systems requiring 24-hour bacup. Other options include a 25 Watt, 25 Vrms audio amplifier for system expansion to 50 Watts (providing dual 25 Watt speaker circuits) or as a secondary, backup amplifier. A 70.7 Vrms converter is also available for independently converting amplifier to meet retrofit needs. Suitable applications include, but are not limited to: schools, auditoriums, dormitories, theaters, restaurants, places of worship, motels/hotels, office buildings, factories, etc. Features:
GENERAL INFORMATION The FireLite ACC-25/50DAZS is a state-of-the-art, compact, DA (Distributed Audio) panel which is designed to interface directly to addressable or conventional fire alarm control panels or can be automatically activated via the Audio Command Center25/50 (ACC-25/50) Series' Zone System serial communications link. The ACC-25/50DAZS is offereed in a self-contained, cost effective modular design that includes a single channel, 25 Watt, 25 Vrms audio amplifier, a zone page module (ACC-APM), and a zone splitter module (ACC-ASM). The additional optional digital message generator module provides a factory-prerecorded voice announcement and field record and playback capability. The ACC-25/50DA, which supports up to eight speaker circuits, can be used to distribute voice evacuation audio over a building's speaker system. The audio riser input provides automatic gain control (AGC) which compensates for any sudio signal loss due to circuit loading or cable length, to ensure delivery of a full output signal to the speakers. The built-in power supply and battery charger provides up to 18 AH for systems requiring 24-hour bacup. Other options include a 25 Watt, 25 Vrms audio amplifier for system expansion to 50 Watts (providing dual 25 Watt speaker circuits) or as a secondary, backup amplifier. A 70.7 Vrms converter is also available for independently converting amplifier to meet retrofit needs. Suitable applications include, but are not limited to: schools, auditoriums, dormitories, theaters, restaurants, places of worship, motels/hotels, office buildings, factories, etc. Features :
BAT-12120: Battery, 12 volt, 12.0 AH, (two required for stand-alone applications; requires BB-17F Battery Box.)
The CMF-300 Addressable Control Module provides Fire-Lite Alarm's MS-9200 and MS-9600 intelligent control panels.
FCPS-24FS6 Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions.
The FCPS-24FS6 is a compact, cost-effective, 6-amp remote power supply with battery charger. The FCPS-24FS6 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS6 also contains a battery charger capable ofcharging up to 18 Amp Hour batteries.
FEATURES UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex appliances. Cascadable up to 10 power supplies with strobe timing maintained. Operates as a sync follower or a sync generator (default). Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode]). Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF-300) for alarm activation. Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits. 6 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864). 4 Amp continuous output in stand-alone mode (UL 1481). In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two. Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power). Power-limiting technology meets UL power-limiting requirements. Form-C normally-closed trouble relay. Fully supervised power supply, battery and Notification Appliance Circuits. Selectable earth fault detection. AC trouble report selectable for immediate or 8 hour delay. Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, lockable cabinet (15" [381 mm] H x 14.5" [368 mm] W x 2.75" [70 mm] D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. Battery charger may be disabled via dip switch for applications requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.25 mm²) wire.
The FCPS-24FS8 is a compact, cost-effective, 8-amp remote power supply with battery charger. The FCPS-24FS8 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization or auxiliary power to support 24-volt system accessories. The FCPS-24FS8 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS8 also contains a battery charger capable of charging up to 18 Amp Hour batteries.
FEATURES UL Listed NAC Synchronization using System Sensor, Wheelock, or Gentex appliances. Cascadable up to 10 power supplies with strobe timing maintained. Operates as a sync follower or a sync generator (default). Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode]). Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation. Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits. 8 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864). 6 Amp continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power supervision relay (A77-716B) In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two. Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power). Power-limiting technology meets power-limiting requirements. Normally-closed trouble contact. Fully supervised power supply, battery and Notification Appliance Circuits. Selectable earth fault detection. AC trouble report selectable for immediate or 8 hour delay. Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, lockable cabinet (15" [381 mm] H x 14.5" [368 mm] W x 2.75" [70 mm] D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. Battery charger may be disabled via dip switch for applications requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to12 AWG (3.25 mm²) wire.
The SD355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with FireLite's MS-9200, MS-9200UD, and MS-9600 Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).
Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z).
Enter your email for a chance to WIN $100 Amex Gift Card.
Please Enter Your Email Address
*One entry per household please