Sophisticated Performance at Low Cost
The new Fire-Lite MS-5UD-3, five zone, and MS-10UD-7, ten zone, conventional fire control panels have features normally found in more expensive addressable systems.
Key features include:
FL-MS10UD7 / MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet).
The Fire-Lite MS-2 and MS-2E Fire Alarm Control Panels bring the latest in microprocessor technology to conventional fire controls. The MS-2 is compatible with the new i³ smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using three selections for manufacturer protocol. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires. The MS-2 also is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally- open contact devices. For 240 VAC operation, order MS-2E. See the FireLite Device Compatibility Document 15384 for a complete list of compatible devices. NOTE: Unless indicated otherwise, the term MS-2 refers to both MS-2 and MS-2E models.
FEATURES Two Style B (Class B) IDCs (Initiating Device Circuits). One Style Y (Class B) NAC (Notification Appliance Circuit). 24 VDC. i³ Technology features: Drift compensation automatically adjusts detector sensitivity and increases resistance to false alarms caused by dust accumulation. Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. Wireless handheld sensitivity meter eliminates the need for voltmeters, magnets and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication. Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing. Special test protocol and LED indication allows quick test of all detectors without need for a ladder. NAC synchronization features: Provides synchronization of standard ANSI audible signals as required by NFPA 72. Provides synchronization of ADA compliant strobes per NFPA 72. Selectable for System Sensor, Wheelock and Gentex protocols. Selective Silence feature allows manual silence of horns while strobes continue to flash on the same NAC. Silent or Audible Walk Test operation mode commanded from the front keypad, with automatic return to normal after one hour of inactivity. Alarm verification selectable per zone. Each zone may be programmed for supervisory or fire, with separate red and yellow LEDs. Disable switches provided per zone. NACs programmable for: Silence Inhibit Auto Silence Strobe Synchronization Selective Silence (horn-strobe mute) Temporal or Steady signal Silenceable or Nonsilenceable Form-C Alarm and Trouble relays. 3.0 amps total usable current. Optional dress panel (P/N DP-MS2/4).
REPLACES FL-MS4424
GENThe FireLite MS-4 and MS-4E Fire Alarm Control Panels bring the latest in microprocessor technology to conventional fire controls. The MS-4 is compatible with the i³ smoke detectors from System Sensor, and provide such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using three selections for manufacturer protocol. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.
The MS-4 also is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. For 240 VAC operation, order MS-4E. See the FireLite Device Compatibility Document 15384 for a complete list of compatible devices. NOTE: Unless indicated otherwise, the term MS-4 refers to both MS-4 and MS-4E models.
FEATURES Four Style B (Class B) IDCs (Initiating Device Circuits). Two Style Y (Class B) NACs (Notification Appliance Circuits). Optional module that converts all four IDCs and two NACs to Class A. 24 VDC. i³ Technology features: Drift compensation automatically adjusts detector sensitivity and increases resistance to false alarms caused by dust accumulation. Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. Wireless hand-held sensitivity meter eliminates the need for voltmeters, magnets and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication. Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing. Special test protocol and LED indication allows quick test of all detectors without need for a ladder. NAC synchronization features: Provides synchronization of standard ANSI audible signals as required by NFPA 72. Provides synchronization of ADA compliant strobes per NFPA 72. Selectable for System Sensor, Wheelock and Gentex protocols. Selective Silence feature allows manual silence of horns while strobes continue to flash on the same NAC. Silent or Audible Walk Test operation mode commanded from the front keypad, with automatic return to normal after one hour of inactivity. Programmable for combination tamper supervisory monitor and waterflow alarm on one zone. Alarm verification selectable per zone. Each zone may be programmed for supervisory or fire, with separate red and yellow LEDs. Disable switches provided per zone. NACs programmable for: Silence Inhibit Auto Silence Strobe Synchronization Selective Silence (horn-strobe mute) Temporal or Steady signal Silenceable or Nonsilenceable Form-C Alarm, Trouble and Supervisory relays. 3.0 A total usable current. 6.0 A total usable current available with optional second transformer. Optional dress panel (P/N DP-MS2/4).
REPLACES FL-MS4424 FL-MS4424B
FL-MS5UD3 / MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet).
Sophisticated Performance at the Cost of a Conventional System. The MS-9050UD Fire Alarm Control Panel offers state-of-the-art technology with easy installation, operation, and maintenance. Suited for stand-alone applications, the MS-9050UD is ideal for smaller facilities such as apartment complexes, banks, cinemas, child care and elementary schools, department stores, food stores, places of worship, restaurants, small retail outlet stores, and other facilities requiring performance-based, sophisticated technology at reasonable cost.
With capabilities such as remote upload/download programming and diagnostics, addressable point identification, drift compensation, built-in digital communication, and NAC synchronization, the MS-9050UD delivers features typically found only in more expensive, larger systems.
High Performance with Remarkable Flexibility. The panel supports a wide range of addressable sensors, control outputs, and notification devices capable of meeting the most challenging design specifications. With support for up to 50 addressable points of any type on a single SLC loop, the MS-9050UD provides advanced addressable features at a price that competes with conventional systems.
With an integrated Digital Alarm Communicator Transmitter (DACT) for off-premises monitoring and remote Upload/Download programming support, the MS-9050UD is a compact Fire Alarm Control Panel that provides large system technology with remarkable flexibility.
The Fire-Lite AUDIO-COMMAND-CENTER-25/50 (ACC-25/50) is a state-of-the-art, single- or dual-circuit (25 watts each) Emergency Voice Evacuation Control Panel (EVAC). The ACC-25/50 provides the ability to record five field-programmable messages (up to 60 seconds total message duration) with an integral commercial-grade emergency communications microphone or from an external audio source.
Significant technological enhancements set the ACC-25/50 apart from other EVAC panels these include full supervision in both active (alarm or music) and standby conditions, supervision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power supply is capable of charging up to 18 AH batteries, which can be housed in the ACC-25/50 cabinet.
The ACC-25/50 is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts (providing dual 25-watt speaker circuits) or as a secondary amplifier in jurisdictions requiring such backup. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, non-fire, multi-language, etc.) make the ACC-25/50 the most versatile voice evacuation system available.
Some Suitable Applications: Schools Auditoriums Dormitories Theatres Restaurants Places of Worship Lodging Office Buildings Factories
STANDARD FEATURES Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style Y (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25). Modular design for maximum system flexibility and ease of service. Five Command Input Circuits (CMD) are available for activation by an FACP. Two command input circuits can be independently field programmed for activation by a Notification Appliance Circuit (NAC) or contact closure. Three command input circuits activate on contact closure. Manual deactivation of speaker zones. Command inputs allow: One 60-second message. Two 30-second messages. Three 20-second messages. Four 15-second messages. Five 12-second messages. Microphone time-out feature. Nineteen different system and diagnostic LEDs. Two Form-C trouble relays (System & AC Power Loss). Optional equipment: second amplifier; local playback speaker; and remote microphone. Integral digital message generator with standard, factory- prerecorded emergency evacuation message.
The Audio Command Center-25/50 Zoned System (ACC-25/50ZS) is a state-of-the-art Emergency Voice Evacuation Panel (EVAC) capable of splitting 25 or 50 watts of audio power into up to eight speaker circuits (i.e., zones). The ACC-25/50ZS provides the ability to record five field-programmable messages (up to 60 seconds total message duration) with an integral commercial-grade emergency communications microphone or from an external audio source. Significant technological enhancements set the ACC-25/50ZS apart from other EVAC panels these include full supervision in both active alarm and standby conditions, supervision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power supply is capable of charging up to 18 AH batteries, which can be housed in the ACC-25/50ZS cabinet.
The ACC-25/50ZS is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts or as a secondary amplifier in jurisdictions requiring such backup. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs.
The Zone Splitter Module (ACC-ZSM) divides the output of the Audio Amplifier Module(s) (ACC-AAM25) into up to eight speaker circuits (i.e., zones). The Zone Page Module with Keypad (ACC-ZPMK) provides full manual control of the speaker circuits, status indication of each of the speaker circuits, and automatic control by the FACP via the ACS serial link connection on the MS-9200UD and MS-9600 Addressable Panels. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, nonfire, multi-language, etc.) make the ACC-25/50ZS the most versatile voice evacuation system available.
Some Suitable Applications:
STANDARD FEATURES 25 watts of audio power can be divided into eight Style Y (Class B) or four Style Z (Class A) speaker circuits (zones), utilizing the zone splitter module (ACC-ZSM). Full manual control of all audio zones provided by zone page module with keypad (ACC-ZPMK). Activation by the FACP using the ACS serial link and/or the five Command (CMD) inputs. ACS serial link compatible with all FireLite FACPs, depending on function. FACP automatically directs the voice message to each or all audio zones. Paging by zone or All-Call. Full status indication (normal, active, fault) of each speaker circuit. Fault indication via ACS serial link and/or the two Form-C trouble relays (System and AC Power Loss). Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style Y (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25). Modular design for maximum system flexibility and ease of service. Two command input circuits can be independently field-programmed for activation by a Notification Appliance Circuit (NAC) or contact closure. Three command input circuits activate on contact closure.